Fatality Assessment and Control Evaluation (FACE) Program |
![]() |
A Forklift Operator Was Killed When His Forklift Was Struck From Behind by a Motor Vehicle | ![]() |
| ||||||||||
SummaryOn September 17, 2004, a 20-year-old forklift operator was killed after being struck by a motor vehicle while driving a forklift on a state highway. The decedent’s employer had rented the forklift from a nearby business and the decedent was returning it at the time of the incident. The employer had planned to follow the decedent in his truck with his emergency flashers on, but needed to get some gasoline first. He instructed the decedent to wait for him, but the decedent decided to leave without him once he was finished with his task. The forklift was only equipped with one flashing light on top; there were no slow-moving vehicle emblems. The decedent was not wearing the seat belt. After crossing to the inside lane of the highway to make a U-turn, the forklift was struck by a vehicle that had just come over a hill and did not have time to react. The decedent was ejected and pinned for 50 minutes under the forklift that landed on him. He was pronounced dead at the scene. Oklahoma Fatality Assessment and Control Evaluation (OKFACE) investigators concluded that to help prevent similar occurrences, employers should:
IntroductionOn September 17, 2004, a 20-year-old forklift operator was killed when the forklift he was operating was struck from behind by a motor vehicle traveling at highway speed. OKFACE investigators were notified of the incident and an interview with a company official was conducted on December 3, 2004. OKFACE investigators also reviewed the death certificate and reports from the Medical Examiner, investigating law enforcement officer, local media, and the Occupational Safety and Health Administration (OSHA). Employer: The victim was employed by a sheet metal fabrication company. The company had been in business for eight years and employed six full-time people at the time of the incident. The company’s work was seasonal and the number of employees could double at other times of the year. On the day of the incident, the victim and the company owner were the only two people working at the site. The company did not have a comprehensive safety program. There were no written task-specific procedures; however, there were some machine-specific safe work procedures. Victim: The 20-year-old male victim had 14 months of experience in metal fabrication and had been working for the same company the entire time. He had several months of on-the-job experience operating the company’s forklift, but was driving rented equipment at the time of the incident. He had not received any formal forklift training. Training: Monthly safety meetings were held, but the company maintained no documentation of any training that was completed by employees. Machine-specific training for the metal working tools was conducted by videos and on-the-job training. All forklift training was conducted informally on-the-job. The company owner and/or shop foreman selected a responsible employee and then showed him how to operate the equipment. Once the management observed the new operator and felt comfortable with his ability, the employee was allowed to use the forklift as needed. At the time of incident, only the owner, foreman, and decedent were authorized to operate the forklift. Incident Scene: The incident occurred on a straight, downgrade section of four-lane divided state highway (Figure 1). The posted speed limit was 65 miles per hour. Road conditions were dry asphalt. The incident occurred just before 4:00 p.m. Weather: On the day of the incident, the weather conditions were dry and sunny. The temperature was between 60 and 70 degrees Fahrenheit. Back to TopInvestigationOn the day of the incident, the decedent was assigned to unload equipment into a storage facility. All equipment that could be unloaded by hand was, but a forklift was needed to finish the job. The company’s forklift was out of service at the time, so the owner arranged to rent a replacement from another nearby business. The decedent was sent to pick up the forklift, which was about three miles away, and drive it back to the site. The owner followed the decedent to the storage facility in his pickup truck with the emergency flashers on. When nearly all of the equipment had been unloaded, the owner instructed the decedent to finish and then wait for him before returning the forklift. The owner left to put gasoline in his pickup truck and planned to return and follow the decedent. The forklift, a standard size industrial model with a maximum speed of 10 to 15 miles per hour, had only one flashing light on its top; there was not a slow-moving vehicle emblem or any other warning signs on it. While the owner was gone, the decedent finished the job and decided to start driving back on the highway. After traveling only a short distance to the west, he needed to U-turn at an intersection to return to the east and head back into town. The decedent, traveling downhill, moved into the inside lane in preparation of where the highway widened with a left turn only lane. He was almost to the point where he could move into the turn lane and turn around the center median when a two-door motor vehicle crested the hill at 65 miles per hour. Without sufficient time to react to the slow-moving vehicle, the driver struck the back end of the forklift approximately 528 feet and 5½ seconds from the top of the hill and traveling 60 miles per hour. The driver tried to swerve right just before the collision. The motor vehicle went end-over-end twice and came to rest 130 feet west of the point of impact. The driver was pinned between the dashboard and the driver’s seat for approximately 80 minutes before being extricated and airlifted to the hospital. The forklift overturned on its side 43 feet west of the point of impact. The decedent, who was not wearing a seat belt, was thrown from the operator’s compartment and pinned by the forklift, which rolled on top of him. As the owner returned from getting gasoline, he came upon the incident
and noticed the forklift on its side. The fire department had already
arrived and was trying to extricate the decedent from under the forklift.
It took approximately 50 minutes and a small crane to free the victim.
Emergency medical services personnel pronounced him dead at the scene.
Cause of DeathThe Medical Examiner’s report listed the cause of death as internal injuries due to blunt force trauma. Back to TopRecommendations/DiscussionRecommendation # 1: Employers should consider using a trailer or other means for transporting mobile heavy equipment, such as forklifts, between work sites.Discussion: In instances where it becomes necessary to move mobile heavy equipment between work sites., employers should consider using a trailer or other means of transport, rather than driving the machinery itself. This consideration should be made particularly when the machinery is slow-moving and cannot meet minimum speed requirements or is not equipped with proper lights and turn signals.
| ||||||||||||
![]() |