NIOSH In-house FACE Report 2004-06 |
November 2, 2004 |
Summary
On March 9, 2004, a 16-year-old Hispanic construction laborer on a framing crew
(the victim) was injured when he fell from a job-made elevated work platform (scaffold)
and struck his head on a concrete slab 10 feet 3-inches below at approximately
3:00 p.m. The victim complained of a severe headache to his crew leader and to
his father and uncles, who also worked on the framing crew. The construction project
coordinator employed by the general contractor reportedly told the crew leader
to take the youth to the hospital emergency room, less than a mile from the site.
According to the victim’s father, the framing subcontractor’s crew
leader drove him and his son to a drugstore where they purchased aspirin and,
after giving aspirin to the victim, the crew leader drove them home. The crew
leader returned to work and the victim’s father remained at home with the
victim. When the victim’s uncles returned home from work at approximately
7:30 p.m., the victim was vomiting and unable to walk. The victim’s father
and uncles drove the victim to the crew leader’s home shortly after 7:30
p.m. The crew leader drove the victim and family members to a hospital, stopping
along the way at a medical clinic to seek care, but the clinic had already closed.
The victim arrived at a hospital emergency room at approximately 8:30 p.m. and
was pronounced dead at 9:28 p.m. by an emergency room physician.
NIOSH investigators concluded that, to help prevent similar occurrences, employers
should
- ensure that elevated work platforms meet safety requirements and that
all employees are provided with fall protection when the potential for
falls exists
- ensure that injured workers are provided with appropriate emergency
medical services
- develop, implement, and enforce a comprehensive written safety program
for all workers which includes training in hazard recognition and the
avoidance of unsafe conditions. A written training plan should require
training in fall protection for all employees potentially exposed to
fall hazards.
- ensure that workers who are part of a multilingual workforce comprehend
instructions in safe work procedures for which they are assigned and
understand their rights in the workplace
- pursue every feasible means to obtain the authentic age of each worker
hired and establish work policies that comply with child labor laws
prohibiting youths less than 18 years of age from performing hazardous
work including, for example, operating power-driven circular saws. Employers
should communicate these work policies to all employees.
- ensure that the nearest area office of the Occupational Safety and
Health Administration is notified within 8 hours of a fatality or in-patient
hospitalizations of three or more workers as a result of a work-related
incident at their company.
Additionally, general contractors should
- ensure through contract language that all subcontractors have a comprehensive
safety and health program that addresses all aspects of the jobs they
and their employees will perform; accident investigation and emergency
services procedures; and age and employment eligibility documentation
for all employees that will work on the worksite.
Additionally, the U.S. Department of Labor and employers should
- consider prohibiting youth less than 18 years of age from working
at a height of 6 feet or more from ladders, scaffolds, trees, structures
and machinery.
Introduction
On March 9, 2004, a 16-year-old Hispanic construction laborer on a framing
crew (the victim) was injured when he fell from a job-made elevated work platform
(scaffold) and struck his head on a concrete slab 10 feet 3-inches below. He
died several hours later in a hospital emergency department. On April 7, 2004,
the U.S. Department of Labor (DOL), Wage and Hour Division, notified the National
Institute for Occupational Safety and Health (NIOSH), Division of Safety Research
(DSR) of the incident. On May 12, 2004, a DSR safety and occupational health
specialist met with a federal investigator from the DOL Wage and Hour Division
and reviewed findings from their investigation. On May 13, 2004, the DSR investigator
visited the incident site and interviewed the construction project coordinator.
The DSR investigator interviewed the subcontractor who employed the victim through
an arrangement with a Hispanic crew leader. A statement taken from the crew
leader by his employer several days after the incident that had been translated
into English was reviewed. On May 14, 2004, the DSR investigator discussed the
incident with a detective from the city police department. A telephone interview
was conducted with the South Carolina Occupational Safety and Health Administration
(SCOSHA) compliance officer and supervisor assigned to the case. The cause of
death was obtained from the county coroner.
The victim was paid by a crew leader who was employed by a concrete and framing
subcontractor who had subcontracted with the general contractor to do the framing
and concrete work for a new condominium development. The framing subcontractor
had been in operation for 2 years and employed 5 office staff and a crew leader
who, according to the subcontractor, spoke enough English to understand instructions.
The crew leader was responsible for finding Hispanic laborers to perform framing
and concrete work. The crew leader had 18 Hispanic workers performing framing
work at the time of the incident. The subcontractor’s crew leader was
responsible for finding these workers and for paying them in cash every week
with money provided in a lump sum by the subcontractor. These Hispanic workers
were Mexican nationals who spoke little or no English. Neither the crew leader
nor the subcontractor had obtained documentation of the victim’s date
of birth and it is not certain if they knew that the victim was under age 18.
The general contractor had a written safety program for his employees and employed
a construction project coordinator to provide oversight at the project. The
general contractor’s safety program did not cover employees of subcontractors.
There was a statement in the contract between the general contractor and the
subcontractor that stated that the subcontractor was responsible for meeting
all OSHA safety and health regulations.
The framing subcontractor had a written safety and health plan written in
English. The crew leader reported to the SCOSHA compliance officer that he and
his crew operated under the framing subcontractor’s safety program. There
was no documentation of employee training for any of the employees who were
performing framing work, including the victim.
The victim came to the United States from Mexico in January, 2004, to
work with his father and four uncles who were already working on the framing
crew assembled by the subcontractor’s crew leader. The framing subcontractor
had no previous history of employee fatalities.
Back to Top
Investigation
The victim joined the subcontractor’s framing crew about 2 weeks before
the incident. The victim’s uncles and father had been working with the
framing crew at the condominium construction site for about 6 weeks before the
incident. The crew worked Monday through Saturday from 7:30 a.m. to approximately
6:00 p.m. each day. The condominium project had begun in December 2003 and was
scheduled for completion in 2005.
According to statements made by one of the victim’s uncles, the
victim was working with him on the second floor stairwell of condominium
#48 (Photo 1) at the construction project on
March 9, 2004. While the victim was cutting 2x4’s with a power saw,
his uncle left the area to get materials. As he was walking back with
materials, the victim’s uncle saw the victim falling from the elevated
work platform they had constructed earlier, to a concrete slab at ground
level 10 feet 3-inches below (Photo 2). The time
was approximately 3:00 p.m.
According to statements made by the victim’s father, who was working
nearby on condominium #45, he heard a commotion and ran over to find out what
had happened. He saw his son (the victim) sitting on the concrete. The victim
told him he had fallen and had a severe headache. The father noticed an abrasion
and a bump on his son’s head but no bleeding. The construction project
coordinator came to the scene after hearing the commotion and asked coworkers
what had happened. According to the project coordinator, he instructed the crew
leader in English to take the boy to the hospital less than a mile from the
site. He told investigators that he felt that the crew leader fully understood
his instructions as the crew leader spoke some English and had followed instructions
given in English in the past. The framing subcontractor was not at the site
at the time and was not notified; he learned of the incident several days later.
According to the victim’s father, the crew leader told the victim’s
family members to carry the victim to his van, as the victim was unable to walk.
The crew leader drove the father and his son to a drugstore where they purchased
aspirin and, after giving aspirin to the victim, the crew leader drove them
home. After settling the victim, who at that time was able to walk with help,
into bed to rest, the crew leader returned to work and the victim’s father
remained at home. When the victim’s uncles returned home from work at
approximately 7:30 p.m., the victim was vomiting and unable to walk. The victim’s
father and uncles drove the victim in the family’s car to the crew leader’s
home shortly after 7:30 p.m. The crew leader drove the victim and family members
in his van to a hospital, stopping along the way at a medical clinic to seek
care, but the clinic had already closed. The victim arrived at a hospital emergency
room at approximately 8:30 p.m. and was pronounced dead at 9:28 p.m. by an emergency
room physician. Hospital personnel informed the victim’s family and the
crew leader that the victim had died.
At the time of the victim’s admission to the emergency room, family members
told hospital personnel that the victim had fallen from his bicycle and hit
his head. Because hospital personnel questioned that such extensive injury could
have been caused by a fall from a bicycle, they summoned the county coroner
and county police to investigate. In the meantime, county police had received
several phone calls reporting that a young worker had fallen at a construction
site earlier that day. Family members told city police two days later that they
had been told by the crew leader to give this story about a fall from a bicycle
because the family might be in trouble if police found out that the victim had
been injured at work. According to the construction project coordinator, when
he asked the crew leader near the end of the workday (Tuesday, March 9) how
the victim was doing, the crew leader told him that the victim was okay. When
asked about the victim on March 10th and March 11th, the crew leader, who had
been informed of the victim’s death the evening of the fall on March 9th,
again said the victim was okay. On Saturday morning, March 13, 2004, the news
media arrived at the worksite early in the morning and informed the project
coordinator they were doing a story on the death of a 16-year-old who had died
as a result of a fall at the condominium construction site on Tuesday, March
9th. The condominium developer informed the crew leader’s employer of
the incident and the crew leader provided a written statement that day to his
employer describing his view of what had occurred on the jobsite and related
that it was the victim’s family’s idea, not his, to say the injury
happened because of a fall from a bicycle. The crew leader also reported that
when he requested the father take the victim to the hospital right after the
incident, the victim’s father said no that he should take them home. The
crew leader’s statement was given to his employer on March 13, 2004.
On March 11, 2004, the county detective referred the case to the city police
department because it was determined that the victim had been fatally injured
at a construction site in the city’s jurisdiction. The victim’s
uncle and his father told a city detective that they had provided false information
to the county detective at the hospital. They then described to the city detective
the victim’s fall at work and the events that followed, including the
delay in getting medical attention for the victim. This statement was saved
on tape and a copy was given to the DOL Wage and Hour Division investigator.
Because SCOSHA did not learn about the death until several days after it had
occurred (the police called SCOSHA and reported the incident on March 12, 2004)
and work had progressed by the time of their inspection on March 15, there was
little physical evidence remaining at the site to determine the specifications
of the elevated work platform from which the victim had fallen. A witness statement
obtained from SCOSHA indicated that the work platform was erected between the
balcony and the stairwell at the second story level, but according to the SCOSHA
compliance officer, the witness was not able to describe the materials that
had been used to construct the work platform. SCOSHA’s on site investigation
revealed that one of the scaffold boards fell with the victim. SCOSHA concluded
that workers were not protected against falling from the elevated work platform
or from other elevated surfaces, such as the second story stairwell structure.
The employer had also failed to provide emergency services, and had not reported
the victim’s death to SCOSHA. DOL Wage and Hour Division’s investigation
revealed a violation by the employer of Hazardous Occupations Order # 14 which
includes a prohibition against operation of power-driven circular saws by workers
less than 18 years old. Their investigation also revealed overtime pay violations.
Cause of Death
The coroner’s office reported that the victim’s
death was caused by a subdural hematoma with cerebral edema.
Back to Top
Recommendations/Discussion
Recommendation #1: Employers should ensure that elevated work platforms
meet safety requirements and that all employees are provided with fall
protection when the potential for falls exists.
Discussion: Employers are responsible for
providing their workers with appropriate means for safely performing their
work at elevation, and for providing adequate fall protection and hazard
awareness training. OSHA requires scaffolds to meet safety specifications
for design and use for different types of scaffolds [for details see 29
CFR 1926.451 (a)] and requires that all workers be protected against falling
while working from a scaffold: “Each employee on a scaffold more
than 10 feet (3.1 m) above a lower level shall be protected from falling
to that lower level.” (29 CFR 1926.451)1
OSHA’s standard 29 CFR 1926.4542 identifies
employers’ responsibility to provide training related to hazards of work
on scaffolds, including fall protection. OSHA also addresses an employer’s
duty to have fall protection where there are unprotected sides and edges in
construction work in 29 CFR 1926.501 (b) (1)3:
“each employee on a walking/working surface (horizontal and vertical surface)
with an unprotected side or edge which is 6 feet (1.8m) or more above a lower
level shall be protected from falling by the use of guardrail systems, safety
net systems, or personal fall arrest systems.”
Following the incident, the general contractor assigned workers to install
guardrails on all stairwell platforms and balconies and these were in evidence
when the DSR investigator visited the site on May 13, 2004. No scaffolds were
in use at that time.
Recommendation #2: Employers should ensure that injured workers are provided
with appropriate emergency medical services.
Discussion: OSHA has a medical services
and first aid standard that construction employers are required to meet
[29 CFR 1926.50 (a-f)].4 “The employer
shall ensure the availability of medical personnel for advice and consultation
on matters of occupational health”[29 CFR 1926.50(a)]. “Provisions
shall be made prior to the commencement of the project for prompt medical
attention in case of serious injury” [29 CFR 1926.50 (b)]. “In
the absence of an infirmary, clinic, hospital, or physician, that is reasonably
accessible in terms of time and distance to the worksite, which is available
for the treatment of injured employees, a person who has a valid certificate
in first-aid training from the U.S. Bureau of Mines, the American Red
Cross, or equivalent training that can be verified by documentary evidence,
shall be available at the worksite to render first aid” [29 CFR
1926.50 (c)]. “Proper equipment for prompt transportation of the
injured person to a physician or hospital, or a communication system for
contacting necessary ambulance service, shall be provided”[ 29 CFR
1926.50 (e).] “In areas where 911 is not available, the telephone
numbers of the physician, hospital, or ambulance service, shall be conspicuously
posted” [29 CFR 1926.50 (f)].
There was no policy in place at the jobsite regarding how to respond to an
injury at work. The area where the incident occurred was within an area where
911 services were available, but no call was made to 911. Falls from elevation,
particularly those resulting in a head injury, can lead to serious injuries
that may not be immediately apparent to untrained persons. All injuries at work
should be reported to the employer who should ensure that injured workers are
evaluated by trained persons who are qualified, as indicated above, to provide
prompt emergency medical services.
Recommendation #3: Employers should develop, implement, and enforce a
comprehensive written safety program for all workers which includes training
in hazard recognition and the avoidance of unsafe conditions. A written
training plan should require training in fall protection for all employees
potentially exposed to fall hazards.
Discussion: A comprehensive written safety
program should be developed for all workers which includes training in
hazard recognition and the avoidance of unsafe conditions. It should then
be noted in a company’s comprehensive safety program that certain
types of training are required. For example, employers must ensure that
all of their employees with a potential for exposure to fall hazards are
specifically trained in fall protection and that the training provided
meets training requirements set forth in 29 CFR 1926.4542
and in 29 CFR 1926.503.5
Additional information useful for training workers about fall prevention can
be found in a NIOSH publication Worker deaths by falls: a summary
of surveillance findings and investigative case reports6
which is available through the NIOSH web site at http://www.cdc.gov/niosh
or by calling 1-800-356-4674. This document may serve as an additional
means of communicating safe work procedures to workers.
Recommendation #4: Employers should ensure that workers who are part of
a multilingual workforce comprehend instructions in safe work procedures
for which they are assigned and understand their rights in the workplace.
Discussion: Companies that employ workers
who do not understand English should identify the languages spoken by
their employees, and design, implement, and enforce a multi-language safety
program. To the extent feasible, the safety program should be developed
at a literacy level that corresponds with the literacy level of the company’s
workforce. Employers should evaluate each employee’s comprehension
of safe work procedures through testing and observation. The program,
in addition to being multi-language, should include a competent interpreter
to explain workers’ rights to protection in the workplace, safe
work practices workers are expected to adhere to, specific protection
for all tasks performed, ways to identify and avoid hazards, and who they
should contact when safety and health issues arise. Had the victim’s
family understood that employers are responsible for obtaining necessary
care for injured workers and that workers have a right to this care, emergency
care might have been sought immediately following the incident.
Recommendation #5: Employers should pursue every feasible means to obtain
the authentic age of each worker hired and establish work policies that
comply with child labor laws prohibiting youths less than 18 years of
age from performing hazardous work including, for example, operating power-driven
circular saws. Employers should communicate these work policies to all
employees.
Discussion: Employers should ensure that
the authentic age of each prospective employee is determined before hire
and that workers less than 18 years old are not assigned to perform prohibited
work. 29 CFR 516.2 (a)(3) requires that employers have on file the date
of birth for all employees under age 19 who are subject to minimum wage
and overtime provisions [29 CFR 516.2 (a)(3)].7
If employers do not fully understand the types of work prohibited for
workers under the age of 18, they should contact the U.S. Department of
Labor, Employment Standards Administration (ESA), Wage and Hour Division.
This Division enforces child labor laws under the Fair Labor Standards
Act (FLSA).
The FLSA prohibits employment of workers younger than age 18 in nonagricultural
occupations which the Secretary of Labor has declared to be particularly
hazardous. Hazardous Order (HO) No.14 prohibits persons below the age
of 18 from operating power-driven circular saws. Child labor information
can be obtained by visiting the DOL ESA web site at http://www.dol.gov/esa/.
FLSA employment standards for nonagricultural occupations are listed and
explained in Child Labor Bulletin 101.8
Child labor information can also be obtained by calling or visiting offices
of Federal and State child labor departments, located by using the telephone
directory government pages.
Employers should meet with their workforce to communicate the company’s
policies regarding appropriate work assignments for young workers. They
should explain that young workers are at increased risk for injury at
work and reinforce the importance of assigning youths to appropriate work
tasks. They should provide all staff with a description of the young worker’s
assignments. They should identify the person(s) responsible for supervision
of young workers, inform all staff about assigned supervisors, and direct
staff to notify supervisors immediately if they see young workers performing
hazardous work or working outside their assigned tasks. Resources for
training young workers can be found in a NIOSH Alert: Preventing Deaths,
Injuries and Illnesses of Young Workers9
available through the NIOSH web site at http://www.cdc.gov/niosh
or by calling 1-800-356-4674.
Recommendation #6: Employers should ensure that the nearest area office
of the Occupational Safety and Health Administration is notified within
8 hours of a fatality or in-patient hospitalizations of three or more
workers as a result of a work-related incident at their company.
Discussion: Within 8 hours after the death
of any employee for a work-related incident or the inpatient hospitalization
of three or more employees as a result of a work related incident, employers
must report the fatality/multiple hospitalizations by telephone or in
person to the area office of the Occupational Safety and Health Administration
(OSHA), U.S. Department of Labor, that is nearest to the site of the incident.
Employers may also use the OSHA toll free central telephone number, 1-800-321-OSHA
(1-800-321-6742) [29CFR 1904.39(a)].10
This early reporting allows OSHA investigators to accurately assess the
hazards present and to remove other workers from potentially hazardous
situations. In this incident, the employers did not report the fatality
as required.
Recommendation #7: General contractors should ensure through contract
language that all subcontractors have a comprehensive safety and health
program that addresses all aspects of the jobs they and their workers
will perform; accident investigation and emergency services procedures;
and age and employment eligibility documentation for all employees that
will work on the worksite.
Discussion: General contractors should
ensure thorough contract language that all subcontractors have a comprehensive
safety program that appropriately addresses the tasks their workers perform.
As previously stated, in this instance a bilingual safety program may
have allowed workers to better understand the safe way to perform framing
work. The contractual language should address how medical services and
first aid will be provided as well as a statement that all contractors
will follow DOL Wage and Hour Hazardous Orders, hours of work requirements,
and compensation requirements. Additionally, contract language should
include statements that age and employment eligibility will be documented
for each employee.
General contractors should consider requiring subcontractors to provide
them with a copy of the U.S. Department of Homeland Security, U.S. Citizenship
& Immigration Service Form I-9 (Employment Eligibility Verification
Form) for all employees used on the construction site. Immigration laws
require that all workers (regardless of country of origin) prove they
are authorized to work in the United States. Employers are required to
attest on Form I-9 that the documentation appears to be genuine at the
time of examination.11 Form I-9 can be
downloaded at http://www.uscis.gov/graphics/formsfee/forms/i-9.htm
[Accessed August, 2004].
Recommendation #8: The U.S. Department of Labor and employers should consider
prohibiting youth less than 18 years of age from working at a height of
6 feet or more from ladders, scaffolds, trees, structures and machinery.
Discussion: Current child labor laws prohibiting
especially dangerous types of work for youth (Hazardous Orders) prohibit
work in roofing occupations, but do not prohibit other types of work at
heights. At the request of the US Department of Labor (DOL), NIOSH recently
conducted a review of the Hazardous Orders.12
Among other recommendations, NIOSH recommended that DOL establish a new
Hazardous Order to prohibit youth less than 18 years of age from working
“at a height of 6 feet or more from ladders; scaffolds; trees; and
structures including towers, silos, poles, oil rigs, bridges; and antennas;
and machinery.” This recommendation was based on a review of occupational
injury data and the need for personal protective equipment and strict
adherence to safe work practices to protect workers in environments with
significant fall hazards. Falls consistently rank among the leading causes
of occupational injury deaths.13 An analysis
of deaths of young workers for the years 1992-1997 identified 21 fatal
falls to a lower level among youth less than 18 years of age.12
The fit and effectiveness of personal fall arrest systems have not been
specifically tested for young workers who may not have reached the stature
and body dimensions of adult workers for whom they were designed. Although
federal child labor laws do not currently restrict youth from working
at heights, employers should strongly consider prohibiting this type of
work given the inherent risks and questions about the ability to provide
youth with adequate protection in the event of a fall.
References
- Code of Federal Regulations [2004]. 29 CFR 1926.451. General Requirements.
Washington DC: U.S. Government Printing Office, Office of the Federal
Register.
- Code of Federal Regulations [2004]. 29 CFR 1926.454. Training requirements.
Washington DC: U.S. Government Printing Office, Office of the Federal
Register.
- Code of Federal Regulations [2004]. 29 CFR 1926.501(b)(1). Unprotected
sides and edges. Washington DC: U.S. Government Printing Office, Office
of the Federal Register.
- Code of Federal Regulations [2004]. 29 CFR 1926.50 (a); (b); (c);
(e); (f) respectively. Medical services and first aid. Washington DC:
U.S. Government Printing Office, Office of the Federal Register.
- Code of Federal Regulations [2004]. 29 CFR 1926.503. Training requirements.
Washington DC: U.S. Government Printing Office, Office of the Federal
Register.
- NIOSH [2000]. Worker deaths by falls: a summary of surveillance findings
and investigative case reports. Cincinnati, OH: U.S. Department of Health
and Human Services, Public Health Service, Centers for Disease Control
and Prevention, National Institute for Occupational Safety and Health,
DHHS (NIOSH) Publication No. 2000-116.
- Code of Federal Regulations [2004]. 29 CFR 516.2(a)(3). General Requirements.
Washington DC: U.S. Government Printing Office, Office of the Federal
Register.
- DOL (U.S. Department of Labor)[ 2001]. Child labor requirements in
nonagricultural occupations under the Fair Labor Standards Act. Washington,
DC: U.S. Department of Labor, Employment Standards Administration, Wage
and Hour Division, WH-1330. Child labor Bulletin No. 101.
- NIOSH [2003]. NIOSH Alert: Preventing deaths, injuries, and illness
of young workers. Cincinnati, OH: U.S. Department of Health and Human
Services, Public Health Service, Centers for Disease Control and Prevention,
National Institute for Occupational Safety and Health, DHHS (NIOSH)
Publication No. 2003-128.
- Code of Federal Regulations [2004]. 29 CFR 1904.39(a). Reporting fatalities
and multiple hospitalization incidents to OSHA. Washington DC: U.S.
Government Printing Office, Office of the Federal Register.
- U.S. Department of Homeland Security, U.S. Citizenship & Immigration
Service Form I-9 (Employment Eligibility Verification Form). [http://www.uscis.gov/graphics/formsfee/forms/i-9.htm]
Accessed June, 2006.
- NIOSH [2002]. National Institute for Occupational Safety and Health
(NIOSH) Recommendations to the U.S. Department of Labor for Changes
to the Hazardous Orders—Morgantown, WV: Division of Safety Research.
- Bureau of Labor Statistics [2004]. National Census of Fatal Occupational
Injuries in 2003. Washington, DC: U.S. Department of Labor, Bureau of
Labor Statistics, USDL 04-1830.
Investigator Information
This investigation was conducted by Doloris N. Higgins, Safety and Occupational
Health Specialist, Fatality Investigations Team, Surveillance and Field
Investigations Branch, Division of Safety Research.
Photographs
|
Photo 1. This photo
illustrates condominium #48 (Photograph courtesy of SCOSHA). |
![Close-up view of condominium stairwell and balcony. Shows approximate location of elevated work platform from which the victim fell.](https://webarchive.library.unt.edu/eot2008/20090114092916im_/http://www.cdc.gov/niosh/face/images/full200406c.jpg) |
Photo 2. This photo illustrates
a close-up view of the condominium stairwell and balcony. A white
rectangular box illustrates the approximate location of the elevated
work platform from which the victim fell. The letter A is used to
identify the victim’s approximate location before the fall and
the letter B is used to identify the victim’s approximate location
after the fall [Photograph courtesy of SCOSHA (the white rectangular
box and letters A and B were added by the DSR investigator)]. |
|