Technician Crushed When Aerial Platform Lift Engaged |
|
|||||||||||
SummaryOn April 9, 2005, a 51-year-old security systems technician for a freight shipping company was killed while operating a Gradall aerial platform. The technician was working alone, using the rented aerial platform (an articulating boom lift) to install security camera equipment above the doors of a freight terminal. After completing the wiring of one camera, the technician moved the lift to a second door, and raised the platform to work on the camera there. He apparently engaged the lift control while he was bent over the platform railing, and his head struck the door overhang. The platform continued to rise, pinning and crushing the bent-over technician between the roof overhang and the platform railing. He was discovered by a truck driver, who lowered the platform and called for emergency assistance. Paramedics confirmed the victim dead at the scene.
Recommendations
IntroductionOn April 9, 2005, a 51-year-old security systems technician with a freight shipping company was killed while operating a rented JLG Gradall articulating boom lift – a type of aerial platform – to install security cameras above the doors of a freight terminal. OR-FACE received notification of the incident on April 11, 2005. The employer did not grant permission for an OR-FACE site investigation. This report is based on information from the local police bureau, the medical examiner’s office, and Oregon OSHA. Back to TopInvestigationThe day before the incident, the security technician installed wiring throughout the terminal for the cameras. On the day of the incident, he installed one camera over a dock door, and then moved the lift to a second bay door. Markings indicate that he hit a wall while making a turn, perhaps due to unfamiliarity with the equipment. Once in position, the technician raised the platform over the second bay door.
The technician may have had difficulty with the operation of the lift’s foot pedal and control lever. He apparently depressed the foot pedal and the control lever, and was leaning over the platform railing when the mechanism engaged. When the lift rose, the technician’s head hit the roof overhang. The lift continued to rise, pinning the bent-over technician between the base of the roof overhang and the lift railing. The Gradall operating instructions state that the controls will cease to function if the foot pedal is not depressed for a period of 7 seconds, and will not respond for 2 seconds after being reengaged. There is also a 2-second delay from leaving the control to stop, which equals about 9 in. of travel. Inspection of the machine by the rental company following the incident found no mechanical malfunction, but a separate inspection found the lift mechanism hesitated slightly longer than expected.
There were no witnesses to the event. About 45 minutes after the technician had begun work, a truck driver delivering a trailer entered the terminal dock area. The driver saw the technician slumped face forward over the top rail of the platform, pinned against the roof overhang and not moving. The truck driver lowered the still-running lift about 10 ft, and called for emergency services. Paramedics confirmed the victim dead at the scene. Investigators concluded the technician lacked training in the operation of the Gradall lift by evidence of (a) the lift hitting the terminal wall, (b) required safety equipment was not worn, and (c) no training on the lift was documented from the employer or the rental company. Back to TopCause of DeathTraumatic Compression Asphyxia Recommendations/DiscussionRecommendation #1: All workers using mobile machinery should have adequate training on the proper use and safe operation of the equipment.Although the technician in this incident had years of experience using mobile aerial lifts, he may not have been familiar with the controls of this particular model. There was no evidence that the employer had provided training, or had provisions for retraining and testing to maintain competency. Training on an aerial platform should include inspection of equipment and review of maintenance records prior to use; safe operation of lift controls; limitations of different types of equipment; how to work in tight spaces and avoid overhead obstacles; and procedures in case of emergency. Safe operation includes wearing personal protection equipment such as appropriate fall and head protection. Training must be provided by a qualified individual. Employers should provide this training upon assignment to work with each type of mobile machinery upon delivery of new, leased, or rented equipment. Employers should also ensure that operator proficiency and safe work practices are maintained. This is especially important for workers who work alone. Employers should evaluate operators’ performance at least every 3 years.Recommendation #2: Read and follow the manufacturer's operating manual before using machinery.The manufacturer’s operating manual, containing operating and maintenance instructions, is required to be with the equipment, as provided by ANSI/SIA A92.5 (1995). In this case, the operating manual and the ANSI manual were attached to the lift. The lift was posted: “Operator required to read and understand operation and ANSI manuals before operating,” and the bucket was posted with required body harness and attached lanyard requirements. The Gradall operating manual outlines user responsibilities and operator training, including safety precautions, use and limitations of the controls in the platform and at the ground, emergency controls, safety systems, recognition of a malfunction, use of fall and head protection, and machine operation around overhead obstructions, other moving equipment, and obstacles. Back to To |
||||||||||||
Oregon Case Reports | ||||||||||||