NIOSHTIC-2 No. 20024943


Use of a Test Box to Measure Response Times for Machine-Mounted Monitors

2004

Publication first page
Document cover page
Click the image to enlarge

A technique for use in underground coal mines measures the response times of machine-mounted methane monitors. This technique uses a calibration cup to deliver gas to the sensor head to measure response times. For comparison, in the current study, response times were measured by placing methane sensor heads in a specially designed test box where they were exposed to an atmosphere containing a constant concentration of methane. Response time readings measured in the test box were shorter than those obtained with the calibration cup. The response times measured in the test box were comparable for sensors from three different manufacturers. The effects of dust cap and flame arrestor design on response times were also evaluated using the test box.

Author(s):Taylor-CD, Chilton-JE, Zimmer-JA
Reference:Ganguli R, Bandopadhyay S, eds. Mine Ventilation: Proc 10th U.S./North American Mine Ventilation Symposium, Anchorage, Alaska, May 16-19, 2004. Leiden, Netherlands: Balkema, 2004 May; :177-182