PROTECT-PACE STUDY - The Protection of Left Ventricular Function During Right Ventricular Pacing
This study is not yet open for participant recruitment.
Verified by Medtronic Cardiac Rhythm Disease Management, December 2007
Sponsors and Collaborators: Medtronic Cardiac Rhythm Disease Management
Medtronic
Information provided by: Medtronic Cardiac Rhythm Disease Management
ClinicalTrials.gov Identifier: NCT00461734
  Purpose

This study will be done in patients who require the implantation of a cardiac pacemaker (an electronic device that controls the heartbeat) for complete heart block (a heart rhythm abnormality resulting in a slow heart beat). Pacemakers regulate the heart beat by delivering pulses of electricity through special wires (pacing leads) which are placed inside the heart.

This study will compare two groups of pacemaker patients. Each group will have their pacing leads placed in a particular location in the heart. The purpose of the study is to show whether the position used in one group is better for maintaining effective heart function compared to the position used in the other group.

The leads in one group will be placed in a position called the Right Ventricular Apex. This is the traditional and most frequently used position for pacemaker leads.

The leads in the other group will be placed in a position called the Right Ventricular High Septum. This is a less commonly used position, but may result in health benefits for the patients compared with the Right Ventricular Apex.


Condition Intervention
Left Ventricular Dysfunction
Device: Pacing lead position

Genetics Home Reference related topics: familial atrial fibrillation
MedlinePlus related topics: Ataxia Telangiectasia
U.S. FDA Resources
Study Type: Interventional
Study Design: Treatment, Randomized, Single Blind, Active Control, Parallel Assignment, Efficacy Study
Official Title: PROTECT-PACE STUDY - The Protection of Left Ventricular Function During Right Ventricular Pacing. Does Right Ventricular High-Septal Pacing Improve Outcome Compared With Right Ventricular Apical Pacing?

Further study details as provided by Medtronic Cardiac Rhythm Disease Management:

Primary Outcome Measures:
  • Comparison of change in Left Ventricular Ejection Fraction at 1 and 2 years between the two patient groups.

Secondary Outcome Measures:
  • Incidence of atrial tachyarrhythmia recorded by the pacemakers at 1 and 2 years
  • Worsening of heart failure at 1 and 2 years
  • All cause mortality at 1 and 2 years
  • Incidence of stroke at 1 and 2 years
  • Brain Natriuretic Peptide (BNP) levels at 1 and 2 years
  • NTproBNP levels at 1 and 2 years
  • Echocardiographic measures of cardiac dyssynchrony at 1 and 2 years
  • 6 minute walking distances at 1 and 2 years

Estimated Enrollment: 238
Study Start Date: May 2007
Estimated Study Completion Date: April 2010
Detailed Description:

There is an increasing amount of evidence to suggest that other positions in the heart may be more effective than the conventional Right Ventricular Apex (RVA) position for restoring good heart function. The best site to place a lead has not yet been proven.

This is a study comparing the long term clinical effects of two different lead positions. The measurements taken to assess the clinical effects include:

  • the effectiveness of the heart's pumping action (as measured by ultrasound scans)
  • measurements of how far patients can walk in 6 minutes
  • analysis of blood samples
  • collection of information from the pacemaker about heart rhythm problems

Half of the patients in the study will receive conventional leads placed in the more common RVA position in the heart. The other half will receive a relatively new type of lead placed in what is called the Right Ventricular High Septal (RVHS) position.

In order to fairly compare the outcomes of these two different lead positions this study has been designed as a 'randomized', 'blind' trial. This means that the group which patients will be entered into will be chosen at random and patients will not be told which group they are in.

Patients will each have an equal (50:50) chance of being in either group. By carefully comparing the clinical differences between the two groups of patients, the study aims to prove whether or not there are additional benefits for patients when the RVHS lead position is used.

All leads used in the study have been shown to be safe for patients and are available commercially for implantation. All of the implanting doctors involved in the study are experienced at implanting the pacemakers and leads that will be used in this study.

  Eligibility

Ages Eligible for Study:   18 Years and older
Genders Eligible for Study:   Both
Accepts Healthy Volunteers:   No
Criteria

Inclusion Criteria:

  • Patients with complete heart block and sinus rhythm, scheduled to undergo dual chamber pacemaker implantation OR patients with complete heart block and permanent atrial fibrillation, scheduled to undergo single chamber ventricular pacemaker implantation.
  • Patients aged 18 years or older.

Exclusion Criteria:

  • Patients known to have intermittent heart block.
  • Patients indicated for an Implantable Cardioverter Defibrillator or Cardiac Resynchronization Therapy.
  • Patients following junctional ablation.
  • Patients with a Myocardial Infarction within three months prior to enrollment.
  • Patients that received bypass surgery within three months prior to enrollment.
  • Patients that had a valve replacement within three months prior to enrollment or patients with a mechanical right heart valve.
  • Patients where a right ventricular lead cannot be placed i.e. complex congenital heart disease.
  • Patients with hypertrophic obstructive cardiomyopathy.
  • Patients with acute coronary syndrome, unstable angina, severe mitral regurgitation and/or hemodynamically significant aortic stenosis.
  • Previous implanted pacemaker or cardioverter defibrillator.
  • Known paroxysmal atrial fibrillation or a documented episode of atrial fibrillation prior to enrollment.
  • Patients on amiodarone therapy within the last six months prior to enrollment.
  • Terminal conditions with a life expectancy of less than two years.
  • Participation in any other study that would confound the results of this study.
  • Psychological or emotional problems that may interfere with the volunteer's ability to provide full consent or fully understand the purposes of the study.
  • Pregnant patients or patients who may become pregnant during the time-scale of the study.
  Contacts and Locations
Please refer to this study by its ClinicalTrials.gov identifier: NCT00461734

Contacts
Contact: PROTECT-PACE Study Team medtroniccrmtrials@medtronic.com

Locations
Australia, Queensland
Brisbane, Queensland, Australia
Australia, South Australia
Adelaide, South Australia, Australia
United Kingdom
Birmingham, United Kingdom
Middlesbrough, United Kingdom
Bristol, United Kingdom
Belfast, United Kingdom
Newcastle, United Kingdom
Leicester, United Kingdom
Bournemouth, United Kingdom
Leeds, United Kingdom
Sheffield, United Kingdom
Eastbourne, United Kingdom
Sponsors and Collaborators
Medtronic Cardiac Rhythm Disease Management
Medtronic
Investigators
Study Chair: PROTECT-PACE Team Medtronic
  More Information

Study ID Numbers: PROTECT-PACE Version 1.10
Study First Received: April 17, 2007
Last Updated: December 26, 2007
ClinicalTrials.gov Identifier: NCT00461734  
Health Authority: United Kingdom: National Health Service;   United Kingdom: Research Ethics Committee;   Australia: Human Research Ethics Committee;   Australia: Department of Health and Ageing Therapeutic Goods Administration;   New Zealand: Medsafe

Keywords provided by Medtronic Cardiac Rhythm Disease Management:
Right Ventricular High Septal Pacing
Right Ventricular Apical Pacing
Left Ventricular Dysfunction
Heart Block
Pacemaker
Atrial Fibrillation
Ejection Fraction

Study placed in the following topic categories:
Ventricular Dysfunction
Heart Diseases
Heart Block
Ventricular Dysfunction, Left
Atrial Fibrillation

Additional relevant MeSH terms:
Cardiovascular Diseases

ClinicalTrials.gov processed this record on January 16, 2009