Home
Search
Study Topics
Glossary
|
|
|
|
|
|
Sponsors and Collaborators: |
University of Aarhus Aarhus University Hospital Biomet, Inc. |
---|---|
Information provided by: | University of Aarhus |
ClinicalTrials.gov Identifier: | NCT00175162 |
The purpose of this study is to compare the early migration and periprosthetic bone changes of two total knee arthroplasties fixated with two different type bone cement.
Condition | Intervention |
---|---|
Osteoarthritis |
Device: Osteopal G vs. Refobacin-Palacos R bone cement |
Study Type: | Interventional |
Study Design: | Treatment, Randomized, Double-Blind, Active Control, Parallel Assignment, Safety/Efficacy Study |
Official Title: | A Comparison of Fixation Method in Total Knee Arthroplasty - Low Viscosity Versus High Viscosity Bone Cement. A Prospective Randomized Migration- and Bone Density Study on Primary Cemented Knee Implants. |
Estimated Enrollment: | 50 |
Study Start Date: | April 2007 |
Estimated Study Completion Date: | June 2010 |
Around 4% of total knee arthroplasties (TKA) are revised 15 years after the primary operation, most due to loosening of the implant. About 70 % TKA are fixed with bone cement and in general the results after total knee arthroplasty are excellent and with the existing technique about 95% well functioning prostheses can be expected 10 years post surgery. The most serious late complication to surgery is aseptic loosening of the implants; and this remains one of the main courses of failure of both uncemented and cemented total knee implants.
Implant design, method of fixation, the quality of bone cement, surgerytechnique and the bone mass density are some of the factors that have a large influence on implant stability. Fixation of the tibia baseplates in total knee arthroplasty can be obtained by different type bone cement.
In this project we are using a modular tibia component with a central wedge-shaped stem. Upon randomization at surgery the implant is consolidated in the bone with either low-viscosity or high-viscosity bone cement.
The purpose of this study is to compare the early migration of a total knee implant fixated with two different bone cements using RSA (radio stereophotogrammetric analysis) for evaluation. Furthermore, we will make research into the periprosthetic bone and its changes post surgery using DEXA. Finally, the extend of the expected micromovements between the polyethylen liner and the metal backing of the titanium plateau will be compared and taken into account with the results.
Several factors can influence the long-term survival of cemented TKA. Bone-sclerosing at the tibia condyles may induce a problem with cement penetration into the cancellous bone. Furthermore, blood-contamination in the cancellous bone may reduce the shear-strength at the bone-cement site by 50%. A solid cement-implant interface limits the amount of debris in the interface bringing down the risk of radiolucent lines and osteolysis. The tibial implant used in this study is designed with a rim under the plateau to support the cement layer on the tibial condyles at the time of fixation. The implant has a stem making it more resistant to shearing forces. In this study we primarily consider the bone cement viscosity on the outcome. Both types are used in hip-arthroplasties with good results.
To evaluate both the implant-bone micromotions and the polyethylen-implant micromovements metal markers have been placed on the tibial implants pre-operatively. They will also be inserted into the tibial bone and into the tibial polyethylen intra-operatively allowing us to evaluate stereo x-rays by a photogrammetric computer analyses called RSA at the Orthopaedic Center, Aarhus University Hospital. Follow-up stereo x-rays will be scheduled for 1 week, 3 months, 6 month, 1 years and 2 years post-surgery. Periprostetic bone density will be evaluated at 1 week, 1 year and 2 years upon inclusion at the Orthopaedic Center, Aarhus University Hospital.
Ages Eligible for Study: | 70 Years and older |
Genders Eligible for Study: | Both |
Accepts Healthy Volunteers: | No |
Inclusion Criteria:
Exclusion Criteria:
Denmark | |
Orthopaedic Center, Aarhus University Hospital | |
Aarhus, Denmark, 8000 |
Principal Investigator: | Kjeld Søballe, MD, Prof. | Orthopaedic Center, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark. |
Study ID Numbers: | 20030249 |
Study First Received: | September 10, 2005 |
Last Updated: | May 5, 2008 |
ClinicalTrials.gov Identifier: | NCT00175162 |
Health Authority: | Denmark: The Danish National Committee on Biomedical Research Ethics |
RSA DEXA Genoarthrosis |
Knee Arthroplasty Micromotion of polyethylene liner Cement |
Polymethyl Methacrylate Musculoskeletal Diseases Osteoarthritis |
Joint Diseases Arthritis Rheumatic Diseases |