[Code of Federal Regulations] [Title 46, Volume 4] [Revised as of October 1, 2006] From the U.S. Government Printing Office via GPO Access [CITE: 46CFR111.60-2] [Page 232] TITLE 46_SHIPPING (This book contains parts 90 to 139) CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PART 111_ELECTRIC SYSTEMS_GENERAL REQUIREMENTS--Table of Contents Subpart 111.60_Wiring Materials and Methods Sec. 111.60-2 Specialty cable for communication and RF applications. Specialty cables that cannot pass the flammability test contained in IEEE Std 45, IEEE Std 1202, ANSI/UL 1581 test VW-1, or IEC 332-3 Category A due to unique construction properties, such as certain coaxial cables, must-- (a) Be installed physically separate from all other cable; and (b) Have fire stops installed-- (1) At least every 7 meters (21.5 feet) vertically, up to a maximum of 2 deck heights; (2) At least every 15 meters (46 feet) horizontally; (3) At each penetration of an A or B Class boundary; (4) At each location where the cable enters equipment; or (5) In a cableway that has an A-60 fire rating. [CGD 94-108, 61 FR 28280, June 4, 1996]