[Code of Federal Regulations] [Title 46, Volume 4] [Revised as of October 1, 2006] From the U.S. Government Printing Office via GPO Access [CITE: 46CFR111.105-43] [Page 251] TITLE 46_SHIPPING (This book contains parts 90 to 139) CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PART 111_ELECTRIC SYSTEMS_GENERAL REQUIREMENTS--Table of Contents Subpart 111.105_Hazardous Locations Sec. 111.105-43 Paint stowage or mixing spaces. A space for the stowage or mixing of paint must not have any electric equipment, except: (a) Intrinsically safe electric equipment approved for a Class I, Division 1, Group D (Zone 0 or Zone 1) location; (b) Explosionproof electric equipment approved for a Class I, Division 1, Group D (Zone 0 or Zone 1) location; or (c) Through runs of marine shipboard cable. [CGD 74-125A, 47 FR 15236, Apr. 8, 1982, as amended by CGD 94-108, 61 FR 28285, June 4, 1996; 62 FR 23909, May 1, 1997]