[Code of Federal Regulations]

[Title 46, Volume 4]

[Revised as of October 1, 2006]

From the U.S. Government Printing Office via GPO Access

[CITE: 46CFR111.105-35]



[Page 250]

 

                            TITLE 46_SHIPPING



                  (This book contains parts 90 to 139)

 

   CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED)

 

PART 111_ELECTRIC SYSTEMS_GENERAL REQUIREMENTS--Table of Contents

 

                   Subpart 111.105_Hazardous Locations

 

Sec.  111.105-35  Vessels carrying coal.



    (a) The following are Class II, Division 1, (Zone 10 or Z) locations 

on a vessel that carries coal:

    (1) The interior of each coal bin and hold.

    (2) Each compartment that has a coal transfer point where coal is 

transferred, dropped, or dumped.

    (3) Each open area within 3 meters (10 ft) of a coal transfer point 

where coal is dropped or dumped.

    (b) Each space that has a coal conveyer on a vessel that carries 

coal is a Class II, Division 2, (Zone 11 or Y) space.

    (c) A space that has a coal conveyer on a vessel that carries coal 

must have electrical equipment approved for Class II, Division 2, (Zone 

11 or Y) hazardous locations, except watertight general emergency alarm 

signals.



[CGD 94-108, 61 FR 28285, June 4, 1996]