[Code of Federal Regulations] [Title 46, Volume 4] [Revised as of October 1, 2006] From the U.S. Government Printing Office via GPO Access [CITE: 46CFR111.103-7] [Page 244] TITLE 46_SHIPPING (This book contains parts 90 to 139) CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PART 111_ELECTRIC SYSTEMS_GENERAL REQUIREMENTS--Table of Contents Subpart 111.103_Remote Stopping Systems Sec. 111.103-7 Ventilation stop stations. Each ventilation stop station must: (a) Be protected by an enclosure with a glass-paneled door on the front; (b) Be marked, ``In Case of Fire Break Glass and Operate Switch to Stop Ventilation;'' (c) Have the ``stop'' position of the switch clearly identified; (d) Have a nameplate that identifies the system controlled; and (e) Be arranged so that damage to the switch or cable automatically stops the equipment controlled.