Sec.  111.05-11  Hull return.



    (a) A vessel's hull must not carry current as a conductor except for 

the following systems:

    (1) Impressed current cathodic protection systems.

    (2) Limited and locally grounded systems, such as a battery system 

for engine starting that has a one-wire system and the ground lead 

connected to the engine.

    (3) Insulation level monitoring devices if the circulation current 

does not exceed 30 milliamperes under the most unfavorable conditions.

    (4) Welding systems with hull return except vessels subject to 46 

CFR Subchapter D.