[Code of Federal Regulations] [Title 46, Volume 4] [Revised as of October 1, 2006] From the U.S. Government Printing Office via GPO Access [CITE: 46CFR113.25-20] [Page 266-267] TITLE 46_SHIPPING (This book contains parts 90 to 139) CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PART 113_COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT--Table of Contents Subpart 113.25_General Emergency Alarm Systems Sec. 113.25-20 Marking of equipment. (a) Each general emergency alarm system fused switch and distribution panel must have a fixed nameplate on the outside of its cover that has a description of its function. The rating of fuses must also be shown on the outside of the cover of a fused switch. [[Page 267]] (b) Each general alarm contact maker must be marked ``GENERAL ALARM'' in red letters on a corrosion-resistant plate or on a sign. (c) A contact maker that operates only the general emergency alarm signal in crew quarters, machinery spaces, and work spaces must be marked ``CREW ALARM'' by the method described in paragraph (b) of this section. (d) Each general emergency alarm signal must be marked ``GENERAL ALARM--WHEN EMERGENCY ALARM SIGNAL RINGS GO TO YOUR STATION'' in red letters at least \1/2\ inch high. (e) Each general emergency alarm system distribution panel must have a directory attached to the inside of its cover giving the designation of each circuit, the area supplied by each circuit, and the rating of each circuit fuse. [CGD 74-125A, 47 FR 15272, Apr. 8, 1982, as amended by USCG-2004-18884, 69 FR 58348, Sept. 30, 2004]