[Code of Federal Regulations]

[Title 46, Volume 4]

[Revised as of October 1, 2006]

From the U.S. Government Printing Office via GPO Access

[CITE: 46CFR112.43-7]



[Page 259]

 

                            TITLE 46_SHIPPING



                  (This book contains parts 90 to 139)

 

   CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED)

 

PART 112_EMERGENCY LIGHTING AND POWER SYSTEMS--Table of Contents

 

                Subpart 112.43_Emergency Lighting Systems

 

Sec.  112.43-7  Navigating bridge distribution panel.



    (a) Except as allowed in paragraph (b) of this section, the 

following emergency lights must be supplied from a distribution panel on 

the navigating bridge:

    (1) Navigation lights not supplied by the navigation light indicator 

panel.

    (2) Lights for survival craft launching operations under Sec.  

111.75-16, except as allowed in Sec.  112.43-5.

    (3) Signaling lights.

    (4) Emergency lights:

    (i) On open decks;

    (ii) On the navigating bridge;

    (iii) In the chartroom;

    (iv) In the fire control room; and

    (v) For navigation equipment.

    (b) On a mobile offshore drilling unit, the distribution panel 

required in paragraph (a) of this section must be in the control room.

    (c) Each distribution panel required in paragraphs (a) and (b) of 

this section must have a fused switch or circuit breaker for each branch 

circuit.



[CGD 74-125A, 47 FR 15267, Apr. 8, 1982, as amended by CGD 94-108, 61 FR 

28287, June 4, 1996]