EPA 815-N-03-001
March 2003
Certification Officers
Training
Chemistry - June 17-20, 2003
Microbiology - June 23-27, 2003
The Technical Support Center
in Cooperation with the National Exposure Research Laboratory
in Cincinnati provides two 5-day long courses designed to meet
the need for training Federal and State personnel whose reponsibilities
include the evaluation of laboratories analyzing potable water
for chemical and microbiological parameters. Persons who
do not have this responsibility should not apply for these courses.
Persons attending these courses from State facilities must go
through their respective Regional Coordinator in order to secure
their placement in this training.
|
In This Issue...
This issue of the Labcert Bulletin addresses issues which have been
brought to our attention by laboratories, and Regional and State Certification
Officers. You will find articles on the National Environmental Methods
Index (NEMI), recent legislation, Stage1 Disinfectants and Disinfection
Byproducts Rule, chlorite, cyanide, and other drinking water issues.
If there are certification topics you would like to see discussed, please
call, write, fax or e-mail the editors.
Editors:
Ed Glick 513 569-7939, glick.ed@epa.gov
Patricia Hurr 513 569-7678, hurr.pat@epa.gov
Caroline Madding 513 569-7402, madding.caroline@epa.gov
Mailing Address:
U.S. Environmental Protection Agency
Technical Support Center (MS-140)
26 W. Martin Luther King Drive
Cincinnati, OH 45268
Fax Number:
513 569-7191
Contact for USEPA Laboratory
ID Numbers
Every laboratory wishing to be certified to analyze compliance monitoring
drinking water samples must have a unique laboratory ID Number. Laboratories
must include this number when reporting proficiency testing (PT) results.
Charles Feldmann, Office of Ground Water and Drinking Water, Technical
Support Center, is the primary contact for assignment of new laboratory
IDs. He may be reached at 513-569-7671 or FAX: 513-569-7191.
If the laboratory has ever participated in a USEPA-run PT study, the
laboratory will already have a unique ID number. Please review any previous
"study results" report to locate the ID number. If a laboratory cannot
locate this information, the laboratory should contact Mr. Feldmann
for assistance.
Reminder
It is no longer a Federal requirement to monitor for the unregulated
VOCs or to analyze PT samples for these analytes. This requirement was
removed when the UCMR was signed on September 17, 1999.
National Environmental
Methods Index (NEMI)
by Herb Brass
OGWDW/Technical Support Center
NEMI is an Oracle database of environmental method summaries for use
in regulatory and non-regulatory water quality analyses. The database
may be searched from anywhere in the world, free of charge, using the
Internet at www.nemi.gov.
With NEMI, you can compare methods at a glance and find the method that
best meets your needs. NEMI also supports sharing of monitoring data
among different agencies and projects, which may use different methods
at different times. The Advisory Committee on Water Information (ACWI),
the senior advisory committee in the federal government that deals with
water information, has "endorsed the continued development and
timely delivery of NEMI as a vital tool to enhance the generation of
comparable data of known quality, across all entities that conduct water
quality monitoring." A letter announcing the public release of
NEMI was recently co-signed by Diane Regas, then EPA Deputy Assistant
Administrator for Water, and Bob Hirsch, US Geological Survey Associate
Director for Water. The letter can be accessed at: http://water.usgs.gov/wicp/whatsnew.html.
NEMI has been developed under the guidance of the Methods and Data Comparability
Board (MDCB). EPA and USGS co-chair the MDCB, which includes representatives
from the federal, state/tribal, and private sectors. The MDCB and its
parent organization, the National Water Quality Monitoring Council are
committees under ACWI. Currently, NEMI contains information on more
than 600 chemical, microbiological, and radiological water methods that
are used for compliance and other purposes. Regulatory information,
that includes citations in the Federal Register, are available for drinking
water and wastewater methods. For each method, NEMI provides a summary
of the procedure and performance data. Quick method comparisons are
arranged in tables, with supporting details in text. Links are provided
to full methods available on line or, when the methods are proprietary,
a link is provided to the appropriate website, so that the method can
be purchased or otherwise obtained.
The NEMI database was constructed using a state-of-the-art Oracle platform
so that it could accommodate a broad range of method types that require
different data fields and search parameters. The following classes of
methods are currently being or will soon be added -- additional chemical,
microbiological, and radiological methods; biological and field methods;
methods related to water security; and methods used in matrices other
than water. A strategic plan is being developed to accommodate the addition
of these methods consistent with expressed priorities, anticipated resources,
and time.
Rule to Update Drinking
Water and Wastewater Methods
On October 23, 2002, a final “methods update” rule was published
in the Federal Register (Vol. 67, No. 205, pp 65220-65253). This rule
approves updated versions of chemical, microbiological, and radiological
analytical methods developed by ASTM, Standard Methods, the US Geological
Survey, and the Department of Energy. No EPA methods were approved.
The methods apply to the Safe Drinking Water Act and the Clean Water
Act compliance monitoring programs.
A Fact Sheet and the Final Rule are available at http://www.epa.gov/ogwdw/regs.html
and http://www.epa.gov/waterscience/methods/.
Additional Methods Approval
On October 29, 2002, a final rule was published in the Federal Register
(Vol. 67, No. 209, pgs 65888-65902) that approves EPA Method 515.4 to
support previously required NPDWR compliance monitoring for 2,4-D, 2,4,5-TP,
dinoseb, pentachlorophenol, picloram and dalapon. In addition, EPA Method
531.2 is approved for carbofuran and oxamyl. Additional methods approved
in this Federal Register include a method for the determination of atrazine,
two methods for the determination of cyanide, two methods for the determination
of total coliforms and E. coli, a method for the determination of heterotrophic
bacteria, and a method for the determination of turbidity. More information
can be found at http://www.epa.gov/ogwdw/regs.html.
Chlorite Monitoring
Requirements under the Stage 1 DBPR
The Stage 1 Disinfectants/Disinfection Byproducts Rule requires two
types of chlorite monitoring for systems that use chlorine dioxide in
their treatment process: daily monitoring at the entry point to the
distribution system and monthly monitoring at three points in the distribution
system.
Daily chlorite monitoring:
The water entering the distribution system must be analyzed daily for
chlorite using one of three approved analytical methods. Standard Method
4500-ClO2 E is an amperometric method for determining both chlorite
and chlorine dioxide. EPA Method 300.0 and EPA Method 300.1 are both
ion chromatographic methods. It is anticipated that most of the daily
analyses will be performed by treatment plant personnel using SM 4500-ClO2 E. The
rule states that the analyses must be performed by a party approved
by the State. This is the same type of approval that is required to
measure disinfectant residuals such as chlorine dioxide or chlorine.
Distribution system chlorite monitoring:
In order to demonstrate compliance with the chlorite maximum contaminant
level (MCL), water systems using chlorine dioxide must collect a set
of three samples in the distribution system on a monthly basis. One
sample is collected near the first customer, one at a location representative
of average residence time, and the third at a location reflecting maximum
residence time in the distribution system. The samples must be analyzed
using either EPA Method 300.0 or EPA Method 300.1 and the laboratory
must be certified to perform the analysis.
Compliance with the chlorite MCL of 1.0 mg/L is based on the arithmetic
average of each 3-sample set from the distribution system. If any daily
sample at the entry point indicates a chlorite concentration greater
than the MCL, then the water system must collect a set of distribution
system samples on the following day. If none of the daily samples have
chlorite concentrations greater than the MCL, then the distribution
system sampling is only required once each month. A chlorite compliance
determination is made for each 3-sample set.
Stage 1 DBP Rule
The Stage 1 Disinfection By-Product (DBP) Rule which was promulgated
in December 1998 became effective for large surface water systems in
January 2002. These utilities were required to begin monitoring for
additional DBPs at that time. All large surface water systems must monitor
for five haloacetic acids with the summation of their concentrations
to be reported as HAA5 (similar to the concept used for total trihalomethanes).
Utilities that use chlorine dioxide must monitor for chlorite and systems
using ozone must monitor for bromate. This means that laboratories
need to be certified to analyze for HAA5, chlorite and bromate.
The DBP Rule also requires that water systems monitor for TOC. The regulation
requires the TOC analyses be performed by a party approved by the State.
Please contact your states to ascertain they are approving laboratories
for TOC.
Methods 300.0 and
300.1 Differences and Similarities
by Dan Hautman
OGWDW/Technical Support Center
In response to compliance inquiries about the appropriate use of EPA
Method 300.0 and EPA Method 300.1, this article has been prepared to
clarify the differences and similarities, as well as to relate the significance
of these differences to both laboratory certification and the classification
of these methods as approved for compliance monitoring. Both of these
methods employ ion chromatography (IC) with suppressed conductivity
detection, hence, when considering the determinative step, they are
identical. The only real differences between these two procedures are
the specified analytical columns, with their respective eluents, and
for Part B, the "on column" injection volume.
Method 300.1 was written primarily to identify specific parameters (column,
eluent and injection volume) which could be employed to allow the quantitation
of lower concentrations of bromate in drinking water. While doing this
primarily for bromate, it was decided that it would be best to include
all the 300.0 analytes into 300.1. Additionally, we could simplify the
method by specifying a single analytical column for both Parts A and
B, and include some additional QC such as a surrogate analyte.
EPA Method 300.0 is the general purpose IC method approved for compliance
monitoring of fluoride, nitrate, nitrite, chloride, sulfate, and o-phosphate
as well as chlorite at water systems employing chlorine dioxide disinfection.
By closely examining Method 300.0, Section 2.4, regarding method modifications
and Sections 6.2.2.1 and 6.2.2.2 regarding optional analytical columns,
it becomes clear that Method 300.1 completely overlaps into Method 300.0.
A laboratory can adopt the parameters, columns and specifications identified
in 300.1, apply and pass all the required QC that is shown in Section
9 of 300.0, and legitimately claim for certification or approved method
classification that they are using Method 300.0, modified as permitted
in the above referenced sections. The reverse can not be said about
applying the operating conditions found in Method 300.0 to Method 300.1.
Comparable low level measurements of bromate are not possible using
the Method 300.0 standard operating conditions.
Cyanide Clarification
We were recently asked for clarification about the cyanide methods,
specifically, what methods are approved for analysis of cyanide in drinking
water and whether or not distillation is required.
The 1994 Technical Notes (EPA600/R-94/173, October 1994) emphasizes
that spectrophotometric measurements for cyanide in water always
require a manual distillation of the sample to prepare the sample for
measurement. EPA felt the Technical Note was needed because some laboratories
seemed to be unaware of the requirement to distill samples. Although
free cyanide is regulated, the approved spectrophotometric methods are
for total and amenable cyanide; therefore, distillation is required.
The “total” cyanide methods are used to screen samples for
cyanide. If the “total” cyanide level is greater than the
MCL (0.2 mg/L), then analysis for “free” (amenable) cyanide
must be performed to see if the MCL has been exceeded. The “total”
cyanide analysis is still recommended because it is cheaper than the
amenable test.
All approved methods for cyanide are listed at 40 CFR 141.23(k)(1).
The mandatory manual distillation procedure is described in Standard
Method SM-4500–CN-C and ASTM D2036-91. The approved amenable,
manual and automated spectrophotometric methods are shown in the table
below.
Technology (use only after distillation) |
EPA |
ASTM |
SM |
USGS |
Manual Spectrophotometric, Amenable |
|
D2036-91B |
4500-CN-G |
|
Manual Spectrophotometric, Total |
|
D2026-91A |
4500-CN-E |
I-3300-85 |
Semi-automated Spectrophotometric, Total |
335.4 |
|
|
|
Free cyanide can also be determined by one method approved for drinking
water compliance monitoring analysis that does not require distillation,
the specific ion electrode method, SM-4500-CN-F. When using this method,
it is mandatory to maintain a constant ionic strength background for
the electrode measurement, that is, samples and standards must contain
the same concentration of sodium hydroxide. More information concerning
methods can be found in FRN Vol 57, No 138, Friday, July 1992, p 31800.
Sparging Chlorite
Samples
The ion chromatographic methods for chlorite recommend that the sample
be sparged in order to remove any residual chlorine dioxide that may
be present in the sample. This is because chlorite is formed from chlorine
dioxide. Thus, chlorine dioxide will cause a positive bias in the analytical
result if it isn't removed at the time of sample collection.
Most water systems do not use chlorine dioxide as a residual disinfectant,
so usually the water leaving the treatment plant does not contain a
significant chlorine dioxide residual. If this is the case, the water
system does not need to worry about the sparging step. In fact, sparging
chlorite compliance samples is only recommended when chlorine dioxide
is present at a high enough concentration that if it completely converted
to chlorite, it would result in a chlorite concentration near the maximum
contaminant level (MCL) of 1.0 mg/L. Since the chlorine dioxide concentration
is monitored daily at the entry point to the distribution system, water
systems should know whether there is a potential for significant chlorine
dioxide residuals at the chlorite sampling points.
If it is determined that chlorine dioxide poses a potential problem
in chlorite compliance monitoring samples, then the sampler should sparge
the samples at the time of collection. Since chlorine dioxide is volatile,
it is not hard to remove it. The sample should be collected in a clean,
wide-mouth container (such as a beaker or Erlenmeyer flask). The sparging
gas can be obtained by using a lecture bottle of nitrogen or helium
fitted with a regulator and connected to a disposable glass Pasteur
pipette with PVC tubing. The gas flow should be adjusted to produce
a steady flow of bubbles. After 10-15 minutes of sparging, all traces
of chlorine dioxide should be removed from the sample. It can then be
poured from the container into the sample bottle that contains the ethylenediamine
(EDA) preservative.
In order to eliminate potential cross- contamination problems, it is
recommended that a clean container and a new disposable pipette be used
at each sampling point.
A blank should be prepared and analyzed for chlorite prior to the first
field use of the sparging apparatus. Reagent water should be sparged
for 15 minutes and then poured into a sample bottle that contains the
EDA preservative. This blank sample should be analyzed for chlorite
in order to ensure that contaminants are not introduced into the sample
from the sparging gas or the PVC tubing which would interfere with the
chlorite analysis. Periodic preparation and analysis of sparged blanks
is recommended to demonstrate that the sparging procedure does not introduce
interferences.
MICRO PT Q & A
The following are some questions we have received concerning
evaluation of Micro PTs. In the discussion:
Positive = Present
Negative = Absent
1. False Positives: Is it permissible to report a false positive result
on both a total coliform analyte and a fecal coliform/E. coli
analyte in the same or separate samples within the PT set and be considered
"acceptable" for the study?
Yes. One sample (vial) may be missed per analyte. However, a
lab cannot report an “Absent” for a Total Coliform and a
“Present” for Fecal/E. Coli for the same sample (vial) and
have that false positive be considered "acceptable." If a
lab reports “absent” for Total Coliform, the test ends.
2. False Negatives: Does one false negative reported value result in
a "not acceptable" for the PT study, even though a lab could
still pass nine out of ten samples within the set for one analyte but
not the other?
Yes. This means the lab missed a positive sample which is a
public health concern.
3. Analyte Definition: It is my understanding that Total Coliform is
considered one analyte and Fecal Coliform/E. Coli is considered
one analyte.
That is correct.
4. "Acceptable " analysis of a sample: Each PT study consists
of ten samples. If a lab misses one analyte within the sample, is the
sample considered "not acceptable"?
Any false negative or more than one false positive per analyte
would be considered "not acceptable". Otherwise same as answer
No. 1.
Websites that you may find useful are:
www.epa.gov/safewater/regs.html
lists drinking water regulations;
www.epa.gov/safewater/methods/methods.html
lists all promulgated methods and contains copies of some methods;
www.epa.gov/safewater/faq/sco.htm
lists state certification contacts for every state and also gives links
to lists of state laboratories certified for drinking water analyses.
There are links for those states, which have electronic lists of their
certified laboratories;
www.nelac-institute.org/ contains
the NELAC Standards, lists NELAC Accrediting Authorities and accredited
laboratories, and has information about past and future NELAC meetings;
www.ts.nist.gov/ts/htdocs/210/214/scopes/programs.htm
lists NIST-accredited
PT providers;
www.epa.gov/quality/ contains all
EPA Quality Documents and requirements, as well as available QA training
and information about the annual EPA QA meeting.
Interested in acquiring FR Notices?
They make it easier all the time. At http://www.epa.gov/fedreg/subscribe.htm
you can subscribe to have the daily Federal Register delivered to your
email box. You may suscribe to any or all of the 12 categories, one
of which is “Water.” And if your mailbox gets too full,
you can unsubscribe at any time.