CDC logoSafer Healthier People  CDC HomeCDC SearchCDC Health Topics A-Z
NIOSH - National Institute for Occupational Safety and Health

Skip navigation links Search NIOSH  |  NIOSH Home  |  NIOSH Topics  |  Site Index  |  Databases and Information Resources  |  NIOSH Products  |  Contact Us

NPPTL  - The National Personal Protective Technology Laboratory

Concept for CBRN Full Facepiece Air Purifying Respirator (APR) Standard

DRAFT FOR DISCUSSION

(1) Goal:

Develop a NIOSH, NPPTL,tight fitting, full facepiece, air purifying respirator standard that addresses CBRN materials identified as inhalation hazards and/or possible terrorist hazards using a minimum number of filters for emergency responders.

Target: Two (2) filters

 

Short Duration

Long Duration

TIMs

        15 minutes*

      60 minutes*


*See paragraph (6)(a)(2) Gas Life.

(2) Hazards:

NIOSH has been evaluating various lists of chemicals that could be deployed as a result of a terrorist incident. In an effort to reduce the number of certification tests necessary as part of a Chemical Biological Radiological Nuclear (CBRN) Air-Purifying Respirator (APR) standard, efforts have been underway to categorize potential respiratory hazards into families with a representative test agents identified for each family. The following information is a synopsis of this effort to date.

The current carbon technology used in canisters and cartridges were reviewed from existing certification standards. The current standards for gas masks in Europe and the U.S. (NIOSH) were reviewed. The military purchasing specification for ASZM-T carbon for C2A1 military canisters was also reviewed. The most common parameters identified from the review of the military specification and the certification standards were the middle range certification challenges. Some of the test chemicals were considered to be redundant, since other test chemicals would guarantee the carbon effectiveness against the chemicals in question (Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Phosphine, CS & CN Tear Gases). Cyclohexane is the representative chemical for organic vapors. Meeting the organic vapor test for a cartridge will provide protection for all organic vapors having vapor pressures less than that of cyclohexane. From the CWA /TIC list, approximately 61 organic chemicals are cover by this logic, including GB and HD. The acid gases (32 chemicals) are covered by cyanogen chloride, hydrogen cyanide, hydrogen sulfide, and sulfur dioxide. Ammonia represents the base gases, and covers another 4 chemicals on the list. Formaldehyde, phosgene, phosphine and nitrogen dioxide are considered special case chemicals. Phosphine is a hydride and must be removed catalytically (copper+2 and silver impregnates on carbon). Therefore, 108 of the 151 chemicals can be addressed through testing these 10 chemicals. Nine of the test chemicals are listed in ITF 25.


Particulate Biological Agents and Particulate Radiological/Nuclear Agents have also been considered as part of the development of test representative agents. Thirteen biological agents are addressed as part of the standard. They include Anthrax, Brucellosis, Glanders, Pneumonic Plague, Tularemia, Q Fever, Smallpox, Venezuelan Equine Encephalitis, Viral Hemorrhagic Fevers, T-2 Mycotoxins, Botulism, Ricin, and Staphylococcus Enterotoxin B. Sixteen radiological/nuclear agents addressed as part of the standard include Hydrogen 3, Carbon 14, Phosphorous 32, Cobalt 60, Nickel 63, Strontium 90, Technetium 99m, Iodine 131, Cesium 137, Promethium 147, Thallium 204, Radium 226, Thorium 232, Uranium 235 & 238, Plutonium 239, Americium 241.

Chemicals

Organization Using as Test Agent

Ammonia

NIOSH & EN

Cyclohexane

Organic Vapor- EN

Cyanogen Chloride

Military

Formaldehyde

NIOSH

Hydrogen Cyanide

NIOSH, EN & Military

Hydrogen Sulfide

NIOSH & EN

Nitrogen Dioxide

NIOSH & EN

Phosgene

Military

Sulfur Dioxide

NIOSH & EN

Phosphine

NIOSH

 

(3) Respirator Use:

A.  Warm Use: Less than IDLH concentrations, to REL; sustained warm zone support operations; long term use for decon, traffic control, rehabilitation, rescue and recovery; agent known & quantified.

B.  Crisis Provision: Contingency use for short duration, above IDLH concentrations and high physiological (flow) demand possible; Contingency for unforeseen factors such as secondary device or pockets of entrapped hazard. 

    Filter     Configuration       Long Duration Less Than IDLH   Crisis   Panic Demand     Short Duration Less Than IDLH

Filter #1, TIMs

Full Facepiece Back or Chest Mounted

  60 Minutes

  5 Minutes

 

Filter #2, TIMs

Full Facepiece Mask Mounted

 

  5 Minutes

 15 Minutes

C. The CBRN APR filter is a single use filter. After one use the filter is to be discarded.

D. CBRN respirators contaminated with chemical warfare agents are to be disposed of after use.

 

 (4) Filter Test Requirements:


Test Matrix for CBRN Air Purifying Respirators; July 31, 2002

Test Order

Penetration and Permeation Testing

Particulate
Testing

Service Life Testing,
64 lpm flow

Service Life Testing, high flow

42 CFR
Testing

Drop
 (not order specific)

Human Factors
(not order specific)

Interchangeability
LRPL Test
 

6 APR systems
(3 - GB and 3 - HD)

20 canister Units

60 canister units

30 canister units

3 APR systems

6 Canister Units 
(2 per test)

APR Systems

(12 APR systems per test)

APR Systems
--TBD --

25 to 29 systems

1.

Hot diurnal

Hot diurnal

Hot diurnal

Service Life Testing, 100 LPM

Canister in Parallel Resistance Requirements, 84.112

Major axis vertical, air inlet down

 

EN 136 & EN 148 Mechanical Connector

 

2.

Cold constant

Cold constant

Cold constant

 

Breathing Tube, 84.115

Major axis vertical, air inlet up

Optical Haze

Breathing Resistance
 

3.

Humidity

Humidity

Humidity

 

Facepieces; eyepieces minimum requirements, 84.119

Major axis horizontal

Communications

Dimensions: Size & Weight
 

4.

Transportation vibration

Transportation vibration

Transportation vibration

 

Exhalation valve leakage test, 84.123 (2)

Gas Life Cyclo-hexane

Field of View

Facepiece Leakage  

5.

System testing (GB or HD)

Initial breathing resistance, 84.122

Initial breathing resistance, 84.122

 

Determine CO2 levels (4)

DOP Test (2 minutes)

Fogging

Field of View
 

6.

 

DOP Testing, 84.181

Service Life Testing, 64 LPM

 
Hydration (3)
 

 

   

7.

 

Final breathing resistance, 84.122

Final breathing resistance, 84.122

     

 

   

Notes:

1.The six (6) APR systems may be used in the Penetration and Permeation test.

2. RCT-APR-STP-0004, Determination of Exhalation Valve Leakage Test, APR, STP, dated March 7, 2002 for HF Breathing Resistance:  3 Respirators.

3. RCT-APR-STP-0014, Determination of Leakage of Drinking Tube and Accessories for Respirator Facepieces STP, dated January 14, 2002, for HF Hydration/Drinking Tube:  3 Respirators.

4.  RCT-APR-STP-0064, Determination of Facepiece Carbon Dioxide and Oxygen Concentration Levels of Tight Fitting Powered Air Purifying Respirators with the Blower Unit Off and Tight Fitting Non-Powered Gas Masks with a Tight Fitting Neck Seal STP, dated April 26, 2001 for HF CO2 Test:  3 Respirators.

                                                                                             

 
Warm Zone 
Crisis(1)
 

       Non IDLH (2)

 Greater than IDLH (2)

64 lpm flow

              X

 

high flow 100 lpm

 

           X

Rough handling

              X

           X

(1) Crisis is a high use concentration at a high flow rate, 100 liters, per minute.

(2) Same test concentrations, different flow rates

(5) Special Test Requirements:

(5)(a)  Chemical Agent Permeation and Penetration Resistance Against Distilled Mustard (HD) and Sarin (GB) Agent Requirement

The air purifying respirator system, including all components and accessories shall resist the permeation and penetration of distilled sulfur mustard (HD) and Sarin (GB) chemical agents when tested on an upper-torso manikin connected to a breathing machine operating at an air flow rate of 40 liters per minute (L/min), 36 respirations per minute, 1.1 liters tidal volume.

Test requirements for distilled sulfur mustard (HD) are shown in Table 1.

Table 1: Simultaneous Liquid and Vapor Challenge of APR with Distilled Sulfur Mustard (HD)

 Agent

Challenge(1)
Concentration

Duration of Challenge (min)

Breathing Machine Airflow Rate (L/min)

Maximum Peak Excursion  (mg/m3)

Maximum Breakthrough (concentration integrated over Minimum Service Life) (mg-min/m3)

Number of Systems Tested

Minimum Service Life (hours)

HD-Vapor

300 mg/m3

30

40

0.30(3)

3.0 (4)

3

12 (5)

HD-Liquid

.43 to.86 ml(2)

720

 

(1) Vapor challenge concentration will start immediately after the liquid drops have been applied and the test chamber has been sealed.

(2) Liquid volume dependent on accessories used with the respirator. Minimum volume is .43 ml based on mask and single mask mounted filter/canister.

(3) Three consecutive sequential test data points at or exceeding 0.3 mg/m3 will collectively constitute a failure where each test value is based on a detector sample time of approximately 2 minutes.    

(4) The cumulative Ct including all peak data points must not be exceeded for the duration of the test.

(5) Test period begins upon initial generation of vapor concentrations.

Test requirements for Sarin (GB) agent are shown in Table 2.

Table 2: Vapor Challenge of APR with Sarin (GB)

Challenge Agent

Vapor Concentration (mg/m3)

Vapor Challenge Time (minutes)

Breathing Machine Airflow Rate (L/min)

Maximum Peak Excursion  mg/m3

Maximum Breakthrough  (concentration integrated over Minimum Service Life) (mg-min/m3)

Number of Systems Tested

Minimum Service Life (hours)

GB

210

30(1)

40

0.044 (3)

.75(4)

3

12(2)


(1)The vapor challenge concentration generation will be initiated immediately after test chamber has been sealed.

(2)The test period begins upon initial generation of vapor concentration.

(3)Three consecutive sequential test data points at or exceeding 0.044 mg/m3 will collectively constitute a failure where each test value is based on a detector sample time of approximately 2 minutes.

(4)The cumulative Ct including all peak data points must not be exceeded for the duration of the test.

(5)(b)  Laboratory Respiratory Protection Level (LRPL) Test Requirement:

The measured laboratory respiratory protection level (LRPL) for each full facepiece, air purifying respirator shall be 2000, when the APR facepiece is tested in a negative pressure mode in an atmosphere containing 20-40 mg/m3 corn oil aerosol of a mass median aerodynamic diameter of 0.4 to 0.6 micrometers.

(6) Design Requirements:

(6)(a) Filter Canister Test Challenge, Breakthrough Concentrations, and Filtration Efficiency

 

Test Concentration (ppm)

Draft

Breakthru Concentration (ppm)

 Draft

Ammonia

2500

12.5

Cyanogen Chloride

300

2

Cyclohexane

3900

10

Formaldehyde

1000

1

Hydrogen Cyanide

940

4.7

Hydrogen Sulfide

1000

5.0

Nitrogen Dioxide

200

1

Phosgene

250

1.25

Phosphine

1500

5

Sulfur Dioxide

1500

5

6)(a)(2) Gas Life: The applicant shall identify as part of the application for certification a specified rating period for the filter. Short Duration filter applications shall be identified in 15-minute intervals (15 minutes, 30 minutes, 45 minutes). Long Duration filter applications shall be identified in 30-minute intervals (60 minutes, 90 minutes, 120 minutes).

(6)(a)(3) Particulate / Aerosol filter: The filter shall conform to the P100 filter requirements, as described in 42 CFR, Part 84

(6)(b) Interchangeable consumable filter cartridges and canisters

Interchangeable consumable filter cartridges and canisters are not required as part of CBRN APR certification. Optional approval requirements for manufacturers are identified in the following paragraphs.

(6)(b)(1) Mechanical Connector

The interface between the filter and the facepiece or respirator system shall use a standard thread in accordance with European Standard EN148.1. The filter shall be readily replaceable without use of special tools. The interface connector on the facepiece shall be the female thread and gasket-sealing gland as identified in EN148.1. The filter shall use a male thread in accordance with EN148.1. For respirators where the filter canister is not directly attached to the facepiece, (i.e., not mask mounted) a female thread and gasket sealing gland connector complying with EN 148.1 must be securely attached to a harness system to provide strain relief between the filter and the remaining respirator system.

(6)(b)(1)(b) Gasket Material

In addition to the requirements of EN 148.1, the gasket material shall be ethylene propylene diene monomer, EPDM, with a hardness of 65 + 10 shore A durometer at room temperature.

(6)(b)(2) Performance Requirements for Interchangeability

(6)(b)(2)(a) Breathing Resistance, Facepiece

The facepiece resistance to airflow shall be less than or equal to 10 mm water column when tested at 85 liters per minute.

(6)(b)(2)(b) Breathing Resistance, Mask Mounted (Chin Style) Filter

The filter resistance to airflow shall be less than or equal to 55 mm water column when tested at 85 liters per minute in the initial condition.

(6)(b)(2) (c) Breathing Resistance, Non-Facepiece Mounted Filter

The resistance to airflow for the respirator less facepiece shall be equal to or less than 60 mm water column height when tested at 85 liters per minute.

(6)(b)(2)(d) Dimensions and Weight, Mask Mounted (Chin Style) Filter

The maximum weight of a mask mounted (chin style) filter shall be 500 grams. The maximum size of a mask mounted (chin style) filter shall be such that the filter shall pass (with the threaded connector perpendicular to the diameter opening) through a 5-inch diameter opening.

(6)(b)(2)(e) Facepiece Leakage

A modified laboratory respiratory protection level test (LRPL) shall be performed using eight test subject, with a tariff of two (2) small, four (4) medium, and two (2) large masks. The masks shall be fitted with a test filter weighted to 500 grams and sized to the maximum permissible dimensions of (6)(b)(2)(d). The measured LRPL shall be 2000 when the APR facepiece is tested in an atmosphere containing 20-40 mg/m3 corn aerosol of a mass median diameter of 0.4 to 0.6 micrometers.

(6)(b)(2)(f) Field of View

The field of view test shall be performed with the mask fitted with a filter sized to the maximum permissible dimensions of (6)(b)(2)(d). The requirements of (6)(d)(4) apply:

The full facepiece equipped with a single visor shall be designed so that the effective field of vision shall be not less than 70% related to the natural field of vision, and the overlapped field of vision related to the natural overlapped field of vision, shall not be less than 80%.

A full facepiece equipped with two eyepieces shall be designed so that the effective field of vision shall not be less than 70% related to the natural field of vision, and the overlapped field of vision, shall not be less than 20%.

The field of view test procedure will be developed based on procedures of EN 136.

(6)(c)Rough handling (transportability, temperature range, survivability)

Test

Test Method

Test Condition

Duration

Pass / Fail
Criteria
(1)

Hot Diurnal

Mil-Std-810F, 501.4

71 0 C max, cyclical

3 Weeks

Gas Life, System Permeation / Penetration

Cold Constant

Mil-Std-810F, 502.4

Basic Cold,  -32 0 C

3 Days

Gas Life, System Permeation / Penetration

Humidity

Mil-Std-810E, 507.3

Table 507.3-II, Natural Cycle, Cycle 1

5 Days,

Quick Look

Gas Life, System Permeation / Penetration

Vibration

Mil-Std-810F, 514.5

US Highway Vibration, Unrestrained
Figure 514.5C-1

12 Hours / Axis, 36 Hours Total

(12,000 miles)

Gas Life, System Permeation / Penetration

Drop

3 foot drop onto concrete

Filter Only, 3 Axis

N/A

Gas Life(Cyclohexane only), DOP (2 minutes)

(1) Pass / Fail Criteria is determined after APR has been subjected to Hot, Cold, Humidity and Vibration environmental exposure sequence order.  Pass / Fail Criteria for Drop test is determined after 3 drops, 1 drop per axis, is completed.

(6)(d) Operational Characteristics:

(6)(d)(1) Full Facepiece Fogging

The respirator performance rating for resistance to fogging shall be greater than or equal to 70% when tested in accordance to the fogging test procedure, Appendix A:

(6)(d)(2) Communications

The respirator performance rating for communications shall be greater than or equal to 70% when tested in accordance with the communications test procedure, Appendix B.

(6)(d)(3) Breathing Resistance

Resistance to air flow shall be measured in the facepiece of a CBRN air purifying respirator mounted on a test fixture with air flowing at a continuous rate of 85 liters per minute both before and after each gas service life bench test.  The maximum allowable resistance to air flow is as follows:

  Chin Style Non Facepiece Mounted
Inhalation:     
  Initial    65 mm H2 70 mm H2O
  Final (1)   80 mm H2O 85 mm H2O
Exhalation: 26 mm H2O     26 mm H2O
(1)Measured at end of service life

(6)(d)(4)  Field of View

The full facepiece equipped with a single visor shall be designed so that the effective field of vision shall be not less than 70% related to the natural field of vision, and the overlapped field of vision related to the natural overlapped field of vision, shall not be less than 80%.

A full facepiece equipped with two eyepieces shall be designed so that the effective field of vision shall not be less than 70% related to the natural field of vision, and the overlapped field of vision, shall not be less than 20%.

The field of view test procedure will be developed based on procedures of EN 136.

(6)(d)(5)  Haze (Lens Abrasion)

Specimen CBRN APR facepiece lenses shall be tested for abrasion resistance and the average value of the tested specimens shall not exhibit a delta haze greater than 14%.

The abrasion resistance test procedure will be developed based on NFPA 1981 standard procedures.

(6)(d)(6)  Carbon Dioxide   

The maximum allowable average inhaled CO2 concentration shall be less than or equal to 2%.

Test procedure RCT-APR-STP-0064 is used for carbon dioxide testing.

(6)(d)(7)  Hydration

For CBRN APR respirators equipped with a hydration facility, the CBRN APR respirator shall meet all requirements of the CBRN APR standard with the hydration facility in place.  In addition, dry drinking tube valves, valve seats, or seals will be subjected to a suction of 75mm water column height while in a normal operating position.  Leakage between the valve and the valve seat shall not exceed 30 milliliters per minute.

Test procedure RCT-APR-STP-0014 shall be used to test the hydration facility for leakage.

(6)(e) Quality Assurance Requirements

(6)(f) Extracts from 42 CFR, Part 84

(6)(f)(1)  42 CFR, Part 84 Subparts A, B, D, E, F and G apply in total:

                        Subpart A: General Provisions

                        Subpart B: Application For Approval

                        Subpart D: Approval and Disapproval

                        Subpart E: Quality Control

                        Subpart F: Classification of Approved Respirators

                        Subpart G: General Construction and Performance

(6)(f)(2)  42 CFR, Part 84 Subpart I; the following paragraphs apply:

                        84.110   Gas Masks; description.

                        84.111   Gas masks; required components

                        84.112   Canisters and cartridges in parallel; resistance requirements

                        84.113   Canisters and cartridges; color and markings; requirements

                        84.114   Filters used with canisters and cartridges; location; replacement

                        84.115   Breathing tubes; minimum requirements

                        84.116   Harnesses; installation and construction; minimum requirements

                        84.117   Gas mask containers; minimum requirements

                        84.118   Half-mask facepieces, full facepieces, and mouthpieces; fit; minimum requirements

                        84.119   Facepieces; eyepieces; minimum requirements

                        84.120   Inhalation and exhalation valves; minimum requirements

                        84.121   Head harnesses; minimum requirements

                        84.123   Exhalation valve leakage test

Appendix A - Full Facepiece Fogging

Two individuals with a visual acuity of 20/70 better shall perform each test while wearing the apparatus according to manufacturers directions.  Test participants shall be assigned a properly sized and fitted test respirator for each environmental exposure condition.  All participants shall be trained in the donning and usage of the respirator per manufacturer's instructions.

Prior to testing, visual acuity shall be recorded for each subject while wearing the respirator using Snellen Eye Test charts or an equivalent method.

Test 1

The APR shall be cold soaked in an environmental chamber at minus 21oC (-6oF)for 4 hours.

At the start of each cold temperature wear trial a test participant shall enter the test chamber (maintained at -21oC) and sit quietly for five minutes.  Once the five minute rest period transpires, subjects shall self-don their assigned respirator.

A visual acuity test shall then be administered to quantify the impact of any lens fogging on vision.

The test participant shall then complete a 12-minute work-rest-work regimen comprised of five minutes of exercise, 2 minutes of rest, and an additional five minutes of exercise with the exercise periods consisting of treadmill walking at 4.8 km/hr (3 mph) on a level grade. 

Visual acuity tests shall be repeated at the end of each walk period (i.e., after five minutes of walking and at the end of the 12 minute period immediately following the treadmill walk). 

Test 2

The APR shall be conditioned in an environmental chamber at 15.5oC (60oF), 75% RH for 4 hours.

At the start of each cool/humid temperature wear trial a test participant shall enter the test chamber (maintained at 15.5 C) and sit quietly for five minutes.  Once the five minute rest period transpires, subjects shall self-don their assigned respirator.

A visual acuity test shall then be administered to quantify the impact of any lens fogging on vision.

The test participant shall then complete a 12-minute work-rest-work regimen comprised of five minutes of exercise, 2 minutes of rest, and an additional five minutes of exercise with the exercise periods consisting of treadmill walking at 4.8 km/hr (3 mph) on a level grade. 

Visual acuity tests shall be repeated at the end of each walk period.

Interpretation of Results

Visual acuity scores obtained during each environmental test with the respirator shall be divided by a subject's visual acuity score obtained with the mask prior to testing to calculate a performance rating using the following equation:

            Performance Rating (%) = VACHAMBEREX / VAINITIAL X 100  (1) 

where VAchamber x = visual acuity score during chamber test at time x and VAintial = visual acuity score obtained with the mask prior to testing.

Visual acuity performance ratings calculated from measurements taken post-donning and at the end of each treadmill walk shall be averaged for each individual subject to obtain an average visual acuity performance rating for each subject based on the environmental condition.

Average performance rating for each test participant shall be greater than or equal to 70% for both Test 1 and Test 2 to meet the fogging requirement.
                                                       

Appendix B-Communication

1)      Speech intelligibility testing shall be accomplished through the use of the Modified Rhyme Test (MRT), which evaluates a listener's ability to comprehend single words and provides an indication of speech transmission of the selected words.  The MRT consists of multiple lists of 50 monosyllabic, phonetically balanced words each.  A sample word list is provided in Table 1.Table 1.  Sample MRT stimulus word list

1.    lick 11.  same 21.  pad 31.  pip 41.  name
2.    beat 12.  peal 22.  din 32.  seen 42.  soil
3.    puff 13.  kit 23.  sit 33.  way 43.  fin
4.    cook 14.  sat 24.  win 34.  west 44.  cuff
5.    tip 15.  sin 25.  teak 35.  pace 45.  heal
6.    rave 16.  gold 26.  dent 36.  bat 46.  hark
7.    hang 17.  buff 27.  sub 37.  mop 47.  heat
8.    till 18.  lay 28.  led 38.  big 48.  then
9.    math 19.  nun 29.  tot 39.  tab 49.  law
10.  sale 20.  must 30.  dub 40.  case 50.  bean

2) Three test listeners consisting of two males and one female shall comprise the subject test panel.  All participants shall be tested for "normal" hearing prior to testing by a qualified individual.

3) An additional five individuals (four males and one female) without obvious speech defects or strong regional accents shall serve as MRT speakers.

4) All participants shall be trained in the donning and usage of the respirator per manufacturer's instructions and all shall pass a qualita4tive facepiece-to-face fit check according to the manufacturer's instructions.

5) Procedure:

a. The three test listeners shall be seated opposite a single test speaker for each MRT trial at a distance of 2 meters (6 ft), and they shall be facing one another.  Each listener shall be given a multiple choice answer sheet or positioned before a computer and monitor that will be used to input his or her responses.

b. Data for the MRT will be collected with a steady background noise of 60 dBA consisting of a broadband "pink" noise.  A Brüel and Kjaer Type 1405 Noise Generator or equivalent will be used to produce the background noise.  Background noise levels will be monitored at a position near the listening panel using a Type 2 digital sound level meter and recorded at the beginning, middle, and end of each MRT session.           

c. The test speaker shall present each stimulus word using the carrier phrase "The word is _______." 

d. Speakers will be instructed and trained to maintain a constant output volume at 75 dBA to 85 dBA for all presented words.  A Type 2 digital sound level meter will be positioned in front of the speaker within his or her sight to provide feedback concerning the loudness of their voice during testing.  Speaker output levels will be recorded at the beginning, middle, and end of each MRT session for verification.

e. Listeners will select the word that was perceived to be spoken from a list of six response words presented on the computer monitor by clicking a button on the monitor that corresponds to the perceived word.  If given a paper answer form, subjects will circle their selection.  A sample answer sheet is provided in Figure 1.

f. Test listeners shall then provide a thumbs-up hand signal to the speaker to cue him or her to say the next word.

g.  An individual speaker will present a total of 50 stimulus words to complete one MRT trial.  A different speaker shall then be used to present the next MRT trial.  Test speakers will continue to rotate among the speaker test panel until all trials have been complete. A sample test matrix is provided in Table 2.

h.  Data will be obtained without the respirator and with the respirator worn and operated per the manufacturer's instructions by both speakers and listeners.  All conditions shall be randomly assigned and a different word list shall be used for each test.  Again, an example of a test matrix is provided in Table 2.

Table 2.  Sample MRT test matrix

Speaker

Speaker Condition

Listeners' Condition

Word list

1

No mask

No mask

1

2

No mask

No mask

3

3

Masked

Masked

5

4

Masked

Masked

7

5

No mask

No mask

9

2

Masked

Masked

2

4

No mask

No mask

4

1

Masked

Masked

6

5

Masked

Masked

8

3

No mask

No mask

10


i.  A total of 10 MRT trials shall be performed.  The 10 trials will result in a total of 15 MRT scores (five per listener) for the unworn mask condition and 15 scores for the worn condition.

j.  Listener performance on the MRT shall be scored in terms of the percentage of words correctly identified using the equation:

% correct = (number correct - (number incorrect/5)) * 2                          

(1)The equation accounts for chance or guessing made possible by the multiple-choice form of the answer sheet (Human Engineering Guide to Equipment Design, American Institutes for Research, Washington, DC, 1972).

k. Individual listeners' scores for the unworn and worn respirator conditions shall be averaged for each condition. 

l. Each individual listener's average score with the respirator shall be divided by their average unmasked MRT score to calculate a performance rating (ref equation (2)).  (Because the listening subjects serve as their own controls, the performance rating allows the effect of the respirator condition to be isolated from the effect of the individual).

    formula   (2)

m. The communications requirement shall be met if the average performance rating is greater than or equal to 70%.

mrt listener response sheet


Page last updated: July 31, 2002
Page last reviewed: June 18, 2004
Content Source: National Institute for Occupational Safety and Health (NIOSH)