Iowa FACE 95IA005
Silo Maintenance Worker Dies After Getting Caught in Unloading Auger
Summary: On February 24, 1995 a 27 year old worker for an agricultural maintenance company was killed while repairing a silo bottom unloading auger. The victim was working inside a cement silo filled with corn silage, repairing a sweep auger that was damaged due to frozen feed inside the silo. The worker was lying inside on the floor of the silo behind the auger safety shield when he shouted that he was clear of the auger. A workmate outside at the electric control panel turned on the auger for approximately 15 seconds to dislodge frozen corn silage in the auger. During that time the victim apparently reached to move a trouble light hanging near the auger, and got caught in the moving auger knives, severing his arm and shoulder, and causing severe chest injury. He was taken to a local hospital and pronounced dead on arrival in the emergency room.
RECOMMENDATIONS following our investigation were as follows:
INTRODUCTION
On February 24, 1995 a 27 year old worker for an agricultural equipment maintenance company was killed while repairing a silo unloading auger. On April 11, 1995 the Iowa FACE Program was notified of the incident from the Iowa Medical Examiners office and began an immediate investigation and followed with a site visit on April 27, 1995. Information about this incident was obtained from the County Sheriff’s office, newspaper clippings, the medical examiner’s report, an eye-witness statement and interview, the victim's employer, a farm employee who was present at the scene, and farm owners who had done their own investigation, including the taking of photographs.
The farm had a maintenance contract with a small, out-of-state, agricultural service company which was experienced in silo maintenance and repair. Two employees from this maintenance company were sent to repair a bad bearing and bent end plate of a silo bottom unloading sweep auger. They were an experienced team, working together for the past 3 ½ years. Their company had been in this business for over 12 years, and at that time had 5 employees. Written safety procedures did exist for this company, however safety training was not an on-going concern. Each employee had been trained by the owner in safe procedures while working in silos and especially when working with this particular type of silo auger which has sharp knives along its entire edge. This auger has such a scary appearance that workers frequently remove V-belts when servicing as an extra precaution against auger movement. Clear systems of communication are vital when working on a silo, especially with one man working inside, and another outside operating electric controls. These men had worked together many times and had developed a system of verbal communication, however, in they did not follow a lockout/tagout procedure in this case.
INVESTIGATION
The cement silo is 20 ft. in diameter and 70 ft. tall, used to store corn silage. Over the winter the sweep auger had become damaged from frozen feed inside and needed replacement of the main end bearing and the end plate. Two employees had begun work on this auger a few days before, and had returned to finish the job. The victim had previously entered the silo by removing an access door in its base and tunneling through some of the silage to provide access to the end of the auger. The frozen silage inside the silo was domed over slightly allowing only enough room for crawling. The large amount of silage present in the silo was supported only by the frozen edges near the perimeter of the silo. No shoring was done, the workers relied on the frozen silage not falling on top of them. The victim had hung a trouble light in the area by wrapping its cord around a large screwdriver and jamming this into the frozen silage. He was wearing heavy coveralls and a jacket, as it was a cold day. Oxygen deficiency and the presence of toxic silo gas were not determined, however it should not have been a problem as this was the middle of winter, long after the silo was filled, and the access door had been left open to outside air for a few days.
At the time of the accident the sweep auger was adjacent to the horizontal access door, and the victim was lying behind the auger, on the backside of the sweep, behind the auger shield. The auger was clogged with frozen feed and needed to be cleared before repairs could proceed. The partner was outside, at the opposite side of the silo, next to its electric control panel, preparing to flip the auger switch. He did not have visual contact with the victim who was inside the silo. According to their normal procedures, he asked the victim if he was clear and heard back that he was, then switched on the sweep auger for about 10-15 seconds. A few seconds after the auger was turned off a scream was heard from the victim. He was found in the access tunnel under the silo lying head down on a pile of feed on the floor with his pant leg stuck on a knife of the auger. His left arm and shoulder had been severed and there was extensive injury to his upper chest, and he was complaining of difficulty in breathing.
The county Sheriff and local EMS were called and found easy access to the victim, however he was bleeding badly and was pronounced dead on arrival to the local hospital. The trouble light was not seen at this time, but the co-worker believes it was the only reason that the victim would have reached over the auger shield. He believes it must have been hanging close enough to the auger that the victim tried to move it immediately before or after the auger started. The auger had been repaired, and the silo was operational at the time of our site visit, therefore we did not access the interior of the silo, but made observations from the tunnel under the silo floor.
The exact circumstances of this accident are not known. The victim may have reached for the trouble light; he may have panicked in the narrow space after the auger was turned on; or the auger may have loosened sufficient silage to startle him. Working inside a filled silo is extremely dangerous at any time. The victim thought he was in a safe position behind the auger shield, yet he should have climbed out of the silo, physically away from danger, before his partner turned on the auger. In this type of work a lockout/tagout procedure is required to prevent starting of the auger, intentional or unintentional, while someone is inside the silo.
CAUSE OF DEATH
The death certificate listed death caused by massive trauma due to left arm getting caught in power auger. No autopsy was performed.
RECOMMENDATIONS / DISCUSSION
Recommendation #1: Employers should develop, implement, and enforce a comprehensive written safety program.
Discussion: Repairing silo equipment includes several major hazards such as entanglement, oxygen deficiency, silo gas, and entrapment under falling silage. The employers should have a written safety program to address all potential hazards related to silo equipment repair. The employer should ensure that this program is implemented and enforced on job sites, which are commonly on farms far from the employer’s premises.
Recommendation #2: Employers installing, servicing or repairing silo equipment should provide proper employee training and equipment for confined space entry.
Discussion: 29 CFR 1910.272 (g)(6) states "Employees shall not enter bins, silos, or tanks underneath a bridging condition, or where a buildup of grain products on the sides could fall and bury them." Workers should not enter a silo under these hazardous conditions. Employers should provide training and proper equipment for safe confined space entry. Before entry the workers should ensure that the oxygen level is adequate and there are no silo gases present. Secondly they should ensure by shoring that they will not become entrapped under falling silage.
Recommendation #3: Employers and workers should develop a procedure to prevent intentional and unintentional operation of the unloading mechanism when a worker is inside a silo and in close proximity to the unloading augers.
Discussion: The workers should follow a lockout/tagout procedure, disabling the operating controls, when a worker is inside the silo. Starting the auger can cause entanglement and falling of silage. It is highly unsafe to be in the silo while the auger is operating. The lockout/tagout procedure disables the electric controls. Additional protection can be provided by disconnecting V-belts or other mechanical drives to the auger when someone is working inside the silo.
To contact Iowa State FACE program personnel regarding State-based FACE reports, please use information listed on the Contact Sheet on the NIOSH FACE web site Please contact In-house FACE program personnel regarding In-house FACE reports and to gain assistance when State-FACE program personnel cannot be reached.