Date:         Wed, 7 Apr 2004 21:05:55 EDT
Reply-To:     Association for Recorded Sound Discussion List
              <[log in to unmask]>
Sender:       Association for Recorded Sound Discussion List
              <[log in to unmask]>
From:         Sherwin Cerini <[log in to unmask]>
Subject:      Re: Examining styli for wear.
Comments: To: [log in to unmask]
Content-Type: multipart/alternative;

In a message dated 4/7/2004 9:02:29 PM Eastern Daylight Time, [log in to unmask] writes: > A different Mike replies: It's the cartridge which determines the tracking > force you use. I put the appropriate Shure stylus into a V15 Type II > (ancient, but still first rate) and one gram is ample in a good arm. > Shellac rarely warps, the only situation in which I use more than that to > track LPs (with a different stylus of course and a different cartridge by > preference). > > > Mike > Thank you very much! That is most helpful. I am planning to buy a new TT soon to play my 78s and was hoping there would be a way to reduce the force. Sherwin Cerini