October 16, 2007
The Honorable Thomas P. D'Agostino
Administrator
National Nuclear Security Administration
Dear Mr. D'Agostino:
The Defense
Nuclear Facilities Safety Board (Board) continues to be concerned about the safety of nuclear operations at Los Alamos National
Laboratory (LANL). Many of the Board's
concerns were raised in a public meeting held in
The Board
has become increasingly concerned in the overall lack of progress with respect to safety improvements at LANL. The Board notes that laboratory management
has developed a set of multiyear improvement initiatives in an attempt to
provide long-term solutions to these significant and persistent safety
issues. One initiative is the Safety
Basis Improvement Plan which is designed to provide
high-quality safety bases that meet current requirements for all nuclear
facilities. The Formality of Operations
initiative is an effort intended to strengthen and standardize practices relative to
conduct of operations, engineering, maintenance, and training. Additionally, limited initial actions are being taken to address significant engineering resource
shortfalls highlighted in a recent laboratory staffing analysis. These efforts
appear to be positive and mutually reinforcing.
However, none of these initiatives are mature,
and continued federal and contractor management attention and support are
needed to ensure their success.
These initiatives will take multiple years to drive tangible
improvements at the floor level. The
Board remains convinced that NNSA should focus on rapidly improving credited
safety systems.
This
conviction is supported by the results of a recent review by the Board's staff
that assessed the design, function, and maintenance of selected
safety systems at three of LANL's principal nuclear
facilities: the Plutonium Facility, Weapons Engineering Tritium Facility, and
Chemistry and Metallurgy Research Facility.
The results of the staffs review, which are
included as an enclosure to this letter, indicate that a
number of significant and systemic deficiencies exist at LANL related to
assuring the design, functionality, and maintenance of safety systems. These
deficiencies appear to be widespread, and of varying levels of severity, at each
of the facilities reviewed by the staff. They include the following:
While it is
arguable whether any of the individual system deficiencies identified by the staff constitute an immediate safety concern, their
collective importance and widespread nature warrant immediate attention. In
particular, these issues cast doubt on the laboratory's ability to demonstrate
that credited safety systems can reliably perform their safety functions under
all required design basis conditions. Additionally,
the Board is concerned that the contractor and Los Alamos Site Office are
not providing the level of oversight required to identify the types of issues
reflected in the staffs report. Based on the findings in the enclosed staff
report, the Board lacks confidence in LANL's efforts
to improve the reliability of safety-related systems.
Therefore,
pursuant to 42 U.S.C. § 2286b(d), the Board requests a
report and briefing within 60 days of receipt of this letter describing specific
actions NNSA has taken to (1) facilitate timely and
effective implementation of ongoing safety improvement initiatives for nuclear
operations, (2) rapidly increase confidence in safety systems currently relied
upon in operating nuclear facilities, and (3)
improve the federal oversight of safety
systems at LANL.
Sincerely,
A. J. Eggenberger
Chairman
c: The
Honorable J. Clay Sell
Mr. Mark B. Whitaker, Jr.
Mr. Donald L. Winchell, Jr.
Enclosure
DEFENSE NUCLEAR
FACILITIES SAFETY BOARD
Staff Issue Report
August 31, 2007
MEMORANDUM FOR: J. K. Fortenberry
COPIES: Board Members
FROM: J. L. Shackelford
SUBJECT: Design, Functionality, and Maintenance of Safety
Systems at
This report
documents a review of the design, functionality, and maintenance of safety systems at Los Alamos National Laboratory (LANL), performed
by the staff of the Defense Nuclear Facilities Safety Board (Board). This review was conducted by
B. Broderick, C. Keilers, J. Plaue, C. Roscetti, and J. Shackelford during July 24-26, 2007.
Background. The Board's staff conducted a review at LANL to assess
the design, functionality, and maintenance of selected safety systems at the
Plutonium Facility (PF-4), Weapons Engineering Tritium Facility (WETF), and
Chemistry and Metallurgy Research (CMR) Facility. The review focused on the design, safety
basis, and other calculations and analyses for the selected systems, and
evaluated the functional requirements for the systems
during accident or abnormal conditions. The staff reviewed system test,
surveillance, and maintenance activities to investigate whether the acceptance criteria specified
for these activities were adequately supported by design calculations or other
engineering documents. The review included an assessment of the normal and
emergency operation of the systems to determine whether such operations were governed by approved operating procedures and were
consistent with the design basis.
The staff
noted that some earlier assessments, such as the November 2005 inspection by the Office of Independent Oversight, had identified a
number of deficiencies at LANL regarding design bases, surveillance, and
maintenance. The previous contractor
attempted to address these deficiencies through institutional improvement
initiatives, including the now terminated "Operational Efficiency"
effort. More recently,
the present contractor developed and has begun implementing a new approach
known as the "Formality of Operations" initiative, which includes elements
related to conduct of engineering, operations, maintenance, and training.
This effort is not yet mature or fully implemented. As a result, limited
benefits have been realized at the floor level from
these efforts.
The
following sections summarize the staffs findings regarding the safety systems
that were reviewed at specific laboratory facilities.
Plutonium Facility
Instrument Air System (IAS)-The IAS is identified as a safety-significant system whose function
is to support the safety function of the ventilation system. The system is intended to supply compressed air for the ventilation
system's pneumatic controls and the primary start capability for the
non-safety-related standby diesel generator.
While a
draft is in progress, no formal system design description existed for the IAS
at the time of the staffs review. Further, the system lacked
a complete set of approved engineering drawings. As a result, there was
inadequate formal design information available to support an effective program
of surveillance, testing, and configuration management. For example, it appeared
from an operational perspective that both the quality and moisture content of
the air were important process variables associated with the
system. However, these parameters were not discussed in any of the design documents, and there
were no surveillance or test procedures that verified these parameters. Consequently, the inoperability of the system
air dryers would likely lead to overall system degradation and operability
issues, but no Technical Safety Requirement (TSR) controls or limiting
conditions for operation existed to address this situation.
Other IAS
deficiencies included (I) a lack of permanent system component identifiers, (2) the absence of normal or
abnormal operating procedures, and (3) the lack of a formal calculation for the
setpoint associated with the annual system test used
to verify the ability of the ventilation system to shut down on a loss of air.
Consequently, it was unclear whether the test actually verified the assumptions
set forth in the safety basis.
Vault Water Baths-The vault water baths are identified as a safety-class system to shield the heat-generating plutonium containers from
convective and radiative heat transfer during a fire in the vault room. The system includes a noncredited heat exchanger that is used
to remove heat from the containers. The safety function of the water bath
cooling system does not appear to have been adequately defined,
documented, and assured.
The new and
recently approved system design description is inconsistent with Department of Energy (DOE) Standard
3024-98, Content of System Design
Descriptions, as well as the existing institutional procedure. Specifically, it does not contain an adequate
description of the system requirements and bases. For example, the
system lacks an adequate design calculation addressing the expected system heat
loads. The existing calculation is an informal, poorly documented assessment
that contains a number of mathematical errors, nonconservative
assumptions, and misconceptions regarding fluid flows and heat transfers. Based
on the available system specifications and using conservative
assumptions, the staff performed an assessment of the system and determined
that at the maximum postulated design loading (a parameter not captured in the
system design description, but obtained from the informal calculation), the
system heat exchanger is probably significantly undersized to meet normal system
cooling needs. DOE and the contractor asserted that the heat exchanger is not credited in the safety basis; however, the staff
noted that at the maximum design loading of the plutonium containers, a (much
larger) heat exchanger appeared to be required to prevent boiling in the system.
Other
deficiencies included the following: (I) not all system valves or components were
adequately labeled, and (2) no abnormal operating procedures existed for
the system.
Weapons
Engineering Tritium Facility (WETF)
Tritium Gas
Handling System (TGHS)-The TGHS is
identified as a safety-significant system whose safety function is to provide primary
containment during tritium processing activities.
The TGHS
has an approved system design description; however, the document is incomplete and does not meet the expectations set forth in the
institutional procedure. Additional design information associated with the TGHS
is contained in the WETF Final Safety Analysis Report (FSAR) and other
documentation. The functional requirements of the system include the following
performance criteria:
Notwithstanding
these explicit performance criteria, the only relevant surveillance associated with the TGHS was an annual in-service inspection of
the system that required a visual inspection for signs of wear, degradation, or
unauthorized modifications. This inspection consisted primarily of a
subjective, qualitative assessment of overall system condition, and did not specifically verify any of the safety functions
listed above. Contractor personnel indicated that they relied on various noncredited
operational parameters and operators' system awareness during operations to verify
the safety function of the system, instead of a formal test or surveillance, in
the belief that such testing would be difficult and disruptive. As a result,
the staff concluded that surveillance activities did not
adequately verify the credited safety functions of the system. With respect to overpressure protection, the
staff noted that no formal design calculations were in place to verify that the capacity of the credited system equipment (i.e., the system "dump
tank") was sufficient to handle the design basis overpressure volume. In the case
of overtemperature protection,
it was observed that such protection was afforded by a number of portable
monitoring and circuit interruption devices that were attached to the relevant
system components. However, the safety pedigree of these devices was uncertain.
It also appeared that no formal documented setpoint
calculations taking into account loop and instrument uncertainties were available to demonstrate that the devices could
carry out their desired safety function. There were also no surveillance
requirements associated with verifying and
maintaining this credited safety function.
Other
deficiencies observed regarding the TGHS included the following: (1) the functional requirement for the TGHS to remain leak tight during
an evaluation basis fire had no associated performance criteria; (2) a number of
general guidance documents were available to govern system precautions and
lineups, but no formal operating procedures existed to prescribe the full range of operational alignments; and (3) the
abnormal operating procedures for anticipated system upset conditions were weak and
relied heavily on operator knowledge and training in concert with management
involvement.
Inert and Oxygen Monitoring System
(I&OMS)-The I&OMS provides indication and alarm for a high oxygen concentration in the WETF
gloveboxes. The inerting function of the system provides and maintains an inert
atmosphere to prevent a fire and formation of tritiated water vapor.
A number of deficiencies were identified with respect
to the I&OMS. In particular, the system's alarm setpoint of 4 percent oxygen, which is
credited in the TSR to prevent combustion, lacked a design calculation. This
deficiency was exacerbated by the fact that the methodology for the semiannual
surveillance could result in actuating the alarm as high as
4.5 percent. Moreover, some detectors were unfastened,
which could lead to improper oxygen measurements due to obstruction of the
detectors.
Other
deficiencies noted with the I&OMS included the following: (I) the system
uses two differently scaled meters (0-5 percent and 0-25
percent) to display the oxygen concentrations, which could lead to inconsistencies in
the alarm actuation setpoints; (2) the weekly surveillance procedure only verified that the
system had electrical power. The weekly surveillance could not readily detect a
failed oxygen sensor; and (3) the limited procedures for response to an
elevated oxygen concentration were weak, relied heavily on operator knowledge and
training, and would not necessarily result in elimination of the potential
combustion hazard.
Chemistry
and Metallurgy Research Facility
Wing 9 Hot Cell Door Interlock System-The hot cell door interlocks are a safety-significant system designed to limit radiation
exposure to workers performing operations in the CMR hot cells. The system uses an array of detectors to
monitor radiation and prevent the operation of various combinations of doors,
if elevated radiation levels are detected.
Based on
the geometry of the hot cells and the placement of the detectors, it is not apparent that the calculation used to determine the detector
setpoint of 32 mrem/hr is conservative, especially when the sensitivity of the
detectors is taken into account. The system design also included a delay of 120
seconds to allow sufficient time for the detectors to detect a high-radiation
condition and send a signal to the logic circuits. However, there is no
analysis to support a determination of whether this time interval is sufficient
to achieve the desired safety function.
Other
deficiencies associated with the interlocks included the following: (1) the
system lacked a formal system design calculation; (2) the
periodic surveillance performed to test the safety function of the interlock
only verified the logic circuits and did not physically test whether the
interlock would actually work to prevent door operation; (3) no preventive
maintenance was specified for the flexible hoses used to convey the
high-pressure hydraulic fluid to actuate the 18 ton doors; (4) the backup
hydraulic hand pump would not be capable of shutting an open door after a
hydraulic rupture, and there were no abnormal operating procedures to guide
operator recovery action; and (5) during a walkdown of the system, the staff discovered
an unauthorized temporary modification installed on the system, and the
cognizant system engineer had not been made aware of the modification or its
effects on the system safety function.
Hot Cell Manipulator Boot Seals-The hot
cell manipulator boot seals are identified as a safety-significant system at the CMR Facility. Their
safety function is to prevent or minimize personnel exposure caused by
contamination leakage from the hot cell manipulators.
No formal
system design description had been developed for the boot seals. Rather, the only relevant design information was contained in the
CMR Basis for Interim Operation (BIO) and various system and component
drawings. A more recent (though unapproved) BIO specifically
defines the boot seal safety function as being able to maintain pressure of at
least 0.25 in. wc (water column) with air or nitrogen at a
flow rate of less than 30 scfh (standard cubic feet per hour). The staff found
that no formal surveillance testing or TSRs existed to confirm or otherwise
verify the safety function of the boot seals. Rather, the facility relied on
operator knowledge of the system to ensure that it functioned as expected.
Indications of system operation were available to the operators via pressure
and flow gauges in the vicinity of the controls for the manipulator arms
outside the hot cells. In many cases, however, these indications were well above eye level and would be
difficult to monitor during normal operation.
There were no alarms associated with acceptable leakage thresholds, and
the instrumentation provided did not appear to be in a formal calibration
program.
Other
deficiencies observed with the boot seals included the following: (1) there
were no normal or abnormal operating procedures for the system, and as a
result, it was unclear whether conservative action would be taken following a
loss or malfunction of the boot seal system during operation; (2) maintenance activities
associated with the boot seals relied on an "expert-based system,"
but funding did not exist for such an expert; and (3) system maintenance was documented
primarily by means of a system maintenance log, with parts replaced as needed, presumably
in a run-to-failure mode rather than a more formal, systematic preventive maintenance protocol.
Safety Basis Issues. None of the
facilities assessed were operating under safety bases that fully complied with 10 Code of Federal
Regulations (CFR) Part 830, Nuclear
Safety Management. In particular,
the CMR Facility is operating under a 1998 BIO and associated TSRs, PF-4 is operating under a 1996 FSAR with more
recently developed interim TSRs, and WETF is operating under a 10 CFR
83kompliant documented safety analysis that was approved in 2004, but has undergone none of the
required annual updates. It was evident to the staff that many of the deficiencies identified during
the review resulted in part from the lack of modern and compliant safety bases.
The laboratory's Safety Basis Improvement Plan includes updates for WETF and
PF-4 by the end of fiscal year 2007 and the following year for CMR; however, it
is unclear whether these goals will be met.
DOE Oversight Issues. The staff observed that the oversight
processes of the Los Alamos Site Office and the contractor lacked a
mechanism for identifying the types of issues noted by the staff. Many of the
issues identified as a result of the staffs review represent fundamental
problems related to design bases, operational safety, testing, and maintenance
that should be the routine focus of an effective ongoing oversight process.
Although some of these types of issues had previously been identified by the
contractor and external audits, the staff observed that the site office had not
adequately addressed these issues or their root causes.
Summary.
The staffs review revealed a number of significant deficiencies at
LANL with respect to assuring the design, functionality,
and maintenance of safety systems. These deficiencies included the following:
(1) incomplete or inadequate descriptions of system safety functions, (2) weak
or missing fundamental design information and calculations, (3) failure to
verify credited safety functions through periodic surveillance and testing, (4) failure to implement appropriate maintenance activities to ensure
that safety systems can continue to perform their credited function, (5) lack
of adequate normal and abnormal operating procedures to govern the operation of safety systems, (6) lack of
formal setpoint calculations for critical system operating parameters, and (7)
outdated and, in some cases, inadequate safety bases.
The
development and implementation of a formal, systematic approach to ensuring the
functionality and operability of safety systems that includes robust design
calculations, relevant system testing, fundamental maintenance practices, and
adequate system operating procedures is an essential element of sustainable
safe operations. However, the staff observed that in many cases, the LANL
facilities that were reviewed relied more on expert judgment, operational
awareness, and informal guidance to ensure the operability of safety systems.
The widespread nature of these deficiencies warrants immediate attention.
Consequently, the staff concluded that additional focused actions of an
immediate nature are necessary to identify and resolve these issues and to
improve confidence in credited safety systems.