Northwest EMC - New York LabNVLAP Lab Code: 200761-0
Address and Contact Information:
4939 Jordan Road
Elbridge, NY 13060
Contact: Mr. David M. Tolman
Phone: 503-844-4066
Fax:
E-Mail: dtolman@nwemc.com
Send E-Mail to Laboratory: Northwest EMC
URL: http://www.nwemc.com
NVLAP Accreditation Information
Listed below is the scope of accreditation for this laboratory as of January 8, 2009. For additional information, contact NVLAP at (301) 975-4016.
Send E-Mail to NVLAP at: NVLAP@nist.gov
Electromagnetic Compatibility & Telecommunications
Accreditation Valid From: October 1, 2008 Through: September 30, 2009
[12/610006k] IEC 61000-6-4 (2006-07)
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
[12/610006p] IEC 61000-6-3 (2006-06)
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments
[12/61000g] EN 61000-6-3 (2007)
Electromagnetic compatibility (EMC) - Part 6-3: Generic standard - Emission standard for residential, commericial and light industrial environments
[12/CIS11i] IEC/CISPR 11, Ed. 4.1 (2004-06) + A1(2004)
Industrial, scientific and medical (ISM) radio frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement
[12/CIS11j] EN 55011 (1998) + A1(1999), A2(2002)
Industrial, scientific and medical (ISM) radio frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement
[12/CIS22c4] EN 55022 (1998) + A1(2000) + A2(2003)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
[12/CIS22c5] IEC/CISPR 22, Edition 5 (2005) + A1(2005) + A2 (2006)
Information Technology Equipment - Radio Disturbance Characteristics - Limits and Methods of Measurement
[12/CIS22j] EN 55022 (2006)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
[12/EM02j] EN 61000-3-2 (2006)
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase)
[12/EM03h] IEC/EN 61000-3-3 (1995) + A1 (2001) + A2 (2005)
Conducted Emissions, Voltage Flicker
[12/FCC15b] ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart B
Unintentional Radiators
[12/610006g] IEC 61000-6-2, 1st edition (1999-01)
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments
[12/610006h] IEC 61000-6-1, 2nd edition (2005-03)
Electromagnetic compatibility (EMC) - Part 6: Generic standards - Section 1: Immunity for residential, commercial and light-industrial environments
[12/610006i] IEC 61000-6-2, Edition 2.0 (2005-01)
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments
[12/61000k] EN 61000-6-1 (2007)
Electromagnetic compatibility (EMC) - Part 6 - 1: Generic standards - Immunity for residential, commercial and light-industrial environments
[12/CIS24e] IEC/CISPR 24 (1997) and EN 55024 (1998) + A1(2001), A2(2003)
Information technology equipment - Immunity characteristics - Limits and methods of measurement
[12/I01] IEC 61000-4-2, Ed. 1.2 (2001) + A1, A2; EN 61000-4-2
Electrostatic Discharge Immunity Test
[12/I02g] IEC 61000-4-3, Ed. 3.0 (2006-02)
Electromagnetic compatibility (EMC) - Part 4-3: Testing measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
[12/I03c] IEC 61000-4-4, Ed. 2.0 (2004-07)
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
[12/I04c] IEC 61000-4-5, Ed 1.1 (2005-11)
EMC - Part 4-5: Testing and measurement techniques - Surge immunity test
[12/I05ee] IEC 61000-4-6, Ed. 2.2 (2006-05)
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
[12/I06] IEC 61000-4-8, Ed. 1.1 (2001); EN 61000-4-8
Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
[12/I07c] IEC 61000-4-11, Ed. 2 (2004-03) & EN 61000-4-11
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
- Product Safety Test Methods
[12/60601ab] IEC 60601-1-2, Ed. 3.0 (2007)
Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests
[12/60601e] IEC 60601-1-1 (2000-12), 2nd edition
Medical electrical equipment - Part 1-1: General requirements for safety - Collateral standard: Safety requirements for medical electrical systems
[12/60601h] EN 60601-1-2 (2001)
Medical electrical equipment - Part 1 and Part 1-2: General requirements for safety: Collateral standard: EMC - Requirements and tests
Return to NVLAP Program Listing
NVLAP Home |
Accredited Laboratories |
Fields of Accreditation |
Publications/Applications |
Mutual Recognition Arrangements |
Assessor Resources |
Contact NVLAP ![Return to top of page](https://webarchive.library.unt.edu/eot2008/20090109060904im_/http://ts.nist.gov/standards/images/up.gif)
For questions concerning the National Voluntary Laboratory Accreditation Program, contact us:
National Voluntary Laboratory Accreditation Program, Standards Services Division, NIST, 100 Bureau Drive, Stop 2140, Gaithersburg, MD 20899-2140
Phone: (301) 975-4016, Fax: (301) 926-2884, Email: NVLAP@nist.gov
Date created: July 26, 2002
Last Updated: January 8, 2009
Privacy
Statement / Security Notice / Accessibility Statement | Disclaimer
| FOIA
|