Technology Services, National Voluntary Laboratory Accreditation Program, NIST Go to Technology Services Home Page Go to NIST Home Page Go to National Voluntary Laboratory Accreditation Program Home Page Go to Directory of Accredited Laboratories Go to Fields of Accreditation Go to Publications/Applications Go to Mutual Recognition Arrangements Go to Assessor Resources Contact National Voluntary Laboratory Accreditation Program

Olympus EMC Laboratory

NVLAP Lab Code: 200472-0


Address and Contact Information:

2951 Ishikawa-cho, Hachioji-shi
Tokyo 192-8507
JAPAN
Contact: Mr. Hideyuki Kenjo
Phone: 81-426-42-6613
Fax: 81-426-42-9017
E-Mail: h_kenjo@ot.olympus.co.jp
Send E-Mail to Laboratory: Olympus Corporation EMC Laboratory

NVLAP Accreditation Information

Listed below is the scope of accreditation for this laboratory as of January 8, 2009. For additional information, contact NVLAP at (301) 975-4016.

Send E-Mail to NVLAP at: NVLAP@nist.gov


Electromagnetic Compatibility & Telecommunications

Accreditation Valid From: January 1, 2009 Through: December 31, 2009

  • Emissions Test Methods:

[12/CIS11c] IEC/CISPR 11 (1997), A1 (1999), A2 (2002)
Industrial, Scientific and Medical (ISM) radio frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement

[12/CIS11e] IEC/CISPR 11 (1990), A1(1999), A2(2002) & EN 55011 (1998)
Industrial, scientific and medical (ISM) radio frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement

[12/CIS22] IEC/CISPR 22 (1997) & EN 55022 (1998) + A1(2000)
Limits and methods of measurement of radio disturbance characteristics of information technology equipment

[12/CIS22b] CNS 13438 (1997)
Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment

[12/EM02a]
IEC 61000-3-2, Edition 2.1 (2001-10), EN 61000-3-2 (2000), and AS/NZS 2279.1 (2000): Electromagnetic compatibility (EMC) Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A)

[12/EM03c] IEC/EN 61000-3-3 (1994) with Amendment 1 (2001)
Conducted Emissions, Voltage Flicker

[12/EM03d] IEC/EN 61000-3-3 (1995) + A1 (2001)
Conducted Emissions, Voltage Flicker

[12/FCC15b] ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart B
Unintentional Radiators

[12/T51a] AS/NZS CISPR 22 (2004)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

  • Immunity Test Methods:

[12/61326j] IEC 61326-2-6, Ed. 1.0 (2005-12)
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment

[12/I01] IEC 61000-4-2, Ed. 1.2 (2001); EN 61000-4-2
Electrostatic Discharge Immunity Test

[12/I02] IEC 61000-4-3, Ed. 2.0 (2002-03); EN 61000-4-3 (2002)
Radiated Radio-Frequency Electromagnetic Field Immunity Test

[12/I03] IEC 61000-4-4(1995), A1(2000), A2(2001); EN 61000-4-4
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical Fast Transient/Burst Immunity Test

[12/I04] IEC 61000-4-5, Ed. 1.1 (2001-04); EN 61000-4-5
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test

[12/I05d] IEC 61000-4-6, Ed. 2.1 (2004); EN 61000-4-6
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

[12/I06] IEC 61000-4-8, Ed. 1.1 (2001); EN 61000-4-8
Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test

[12/I07] IEC 61000-4-11, Ed. 1.1 (2001-03); EN 61000-4-11
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests

  • Product Safety Test Methods

[12/60601aa] IEC 60601-1-2, Ed 2.1 (2004-11) & EN 60601-1-2 (2002)
Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests

[12/60601b] IEC 60601-2-2, Ed. 3 (1998)
Medical electrical equipment - Part 2-2, Particular requirements for the safety of high frequency surgical equipment

[12/60601c] IEC 60601-2-18, Ed. 2 (1996)
Medical electrical equipment - Part 2: Particular requirements for the safety of endoscopic equipment

[12/60601d] IEC 60601-2-37, Ed. 1 (2001)
Medical electrical equipment - Part 2-37: Particular requirements for the safety of ultrasonic medical diagnostic and monitoring equipment

[12/60601hh] EN 60601-1-2 (2001) + A1(2006)
Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard: EMC - Requirements and tests

[12/61326a] EN 61326 (1997), A1 (1998), A2 (2001)
Electrical equipment for measurement, control and laboratory use - EMC requirements

[12/61326b] IEC 61326, Ed. 2 (2002-02)
Electrical equipment for measurement, control and laboratory use - EMC requirements

Return to NVLAP Program Listing


Return to top of page NVLAP Home | Accredited Laboratories | Fields of Accreditation | Publications/Applications |
Mutual Recognition Arrangements | Assessor Resources | Contact NVLAP
Return to top of page

For questions concerning the National Voluntary Laboratory Accreditation Program, contact us:

National Voluntary Laboratory Accreditation Program, Standards Services Division, NIST, 100 Bureau Drive, Stop 2140, Gaithersburg, MD 20899-2140
Phone: (301) 975-4016, Fax: (301) 926-2884, Email: NVLAP@nist.gov

Date created: July 26, 2002
Last Updated: January 8, 2009

Privacy Statement / Security Notice / Accessibility Statement | Disclaimer | FOIA