Technology Services, National Voluntary Laboratory Accreditation Program, NIST Go to Technology Services Home Page Go to NIST Home Page Go to National Voluntary Laboratory Accreditation Program Home Page Go to Directory of Accredited Laboratories Go to Fields of Accreditation Go to Publications/Applications Go to Mutual Recognition Arrangements Go to Assessor Resources Contact National Voluntary Laboratory Accreditation Program

US Tech

NVLAP Lab Code: 200162-0


Address and Contact Information:

3505 Francis Circle
Alpharetta, GA 30004
Contact: Mr. John Livingston
Phone: 770-740-0717
Fax: 770-740-1508
E-Mail: jlivingston@ustech-lab.com
Send E-Mail to Laboratory: Scientific Trend , inc. DBA US Tech
URL: http://www.ustech-lab.com

NVLAP Accreditation Information

Listed below is the scope of accreditation for this laboratory as of January 8, 2009. For additional information, contact NVLAP at (301) 975-4016.

Send E-Mail to NVLAP at: NVLAP@nist.gov


Electromagnetic Compatibility & Telecommunications

Accreditation Valid From: July 1, 2008 Through: June 30, 2009

  • Emissions Test Methods:

[12/60E213] RTCA DO-160E
Section 21.3, RF Emissions, Conducted

[12/60E214] RTCA DO-160E
Section 21.4, RF Emissions, Radiated

[12/CIS22] IEC/CISPR 22 (1997) & EN 55022 (1998) + A1(2000)
Limits and methods of measurement of radio disturbance characteristics of information technology equipment

[12/CIS22a] IEC/CISPR 22 (1993) and EN 55022 (1994)
Limits and methods of measurement of radio disturbance characteristics of information technology equipment, Amendment 1 (1995) and Amendment 2 (1996)

[12/CIS22b] CNS 13438 (1997)
Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment

[12/CIS22j] EN 55022 (2006)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

[12/EM02a]
IEC 61000-3-2, Edition 2.1 (2001-10), EN 61000-3-2 (2000), and AS/NZS 2279.1 (2000): Electromagnetic compatibility (EMC) Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A)

[12/EM03b] IEC 61000-3-3, Edition 1.1(2002-03) & EN 61000-3-3, A1(2001)
EMC - Part 3-3: Limits - Limitations of voltage changes, voltage flucuations and flicker, in public low-voltage supply-systems, for equipment with rated current <=16 A per phase and not subject to conditional connections

[12/FCC15b] ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart B
Unintentional Radiators

[12/T51a] AS/NZS CISPR 22 (2004)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

  • Immunity Test Methods:

[12/CIS24c] EN 55024 (1998) and A1 (2001)
Information technology equipment - Immunity characteristics - Limits and methods of measurement

[12/I01] IEC 61000-4-2, Ed. 1.2 (2001) + A1, A2; EN 61000-4-2
Electrostatic Discharge Immunity Test

[12/I02] IEC 61000-4-3, Ed. 2.0 (2002-03); EN 61000-4-3 (2002)
Radiated Radio-Frequency Electromagnetic Field Immunity Test

[12/I03] IEC 61000-4-4(1995), A1(2000), A2(2001); EN 61000-4-4
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical Fast Transient/Burst Immunity Test

[12/I04] IEC 61000-4-5, Ed. 1.1 (2001-04); EN 61000-4-5
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test

[12/I05] IEC 61000-4-6, Ed. 2.0 (2003-05); EN 61000-4-6
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

[12/I06] IEC 61000-4-8, Ed. 1.1 (2001); EN 61000-4-8
Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test

[12/I07] IEC 61000-4-11, Ed. 1.1 (2001-03); EN 61000-4-11
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests

[12/I07c] IEC 61000-4-11, Ed. 2 (2004-03) & EN 61000-4-11
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests

  • Radio Test Methods

[12/300220d] ETSI EN 300 220-1 V2.1.1 (2006-04)
Electromagnetic Compatibility Radio Spectrum Matters; Short Range Devices; Radio Equipment to be used in the 25 MHz to 1,000 MHz Frequency Range with Power Levels Ranging up to 500mW; Part 1: Technical Characteristics and Test Methods

[12/300220e] ETSI EN 300 220-2 V2.1.1 (2006-04)
ERM; Short Range Devices; Radio Equipment to be used in the 25MHz to 1,000 MHz Frequency Range with Power Levels Ranging up to 550 mW; Part 2: Supplementary Parameters Not Intended for Conformity Purposes

[12/301489a] ETSI EN 301 489-1 v1.5.1 (2004-11)
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements

[12/RSS119b] RSS-119, Issue 9 (June 2007)
Land Mobile and Fixed Radio Transmitters and Receivers, 27.41 to 960 MHz

[12/RSS170] RSS-170, Issue 1, Rev. 1 (November 6, 1999)
Satellite Mobile Earth Stations

[12/RSS210a] RSS-210, Issue 7 (June 2007)
Low Power Licence-Exempt Radiocommunication Devices (All Frequency Bands): Category 1 Equipment

[12/RSS310a] RSS-310, Issue 2 (June 2007)
Low Power Licence-Exempt Radiocommunication Devices (All Frequency Bands): Category II Equipment

[12/RSSG2] RSS-Gen, Issue 2 (June 2007)
General Requirements and Information for the Certification of Radiocommunication Equipment

  • Telecommunications Test Methods:

[12/CS03a] Industry Canada CS-03, Issue 9, Amendment 1 (2005)
Compliance Specification for Terminal Equipment, Terminal Systems, Network Protection Devices, Connection Arrangements and Hearing Aids Compatibility

[12/T01]
Terminal Equipment Network Protection Standards, FCC/ACTA Method - 47 CFR Part 68 - Analog and Digital

[12/T01a]
68.302 (Par. c,d,e,f) Environmental simulation; 68.304 Leakage current limit.; 68.306 Hazardous voltage limit.; 68.308 Signal power limit.; 68.310 Longitudinal balance limit.; 68.312 On-hook impedance limit.; 68.314 Billing protection

[12/T01b]
68.316 and 68.317 Hearing Aid Compatibility: technical standards

[12/T01c]
68.302 Environmental simulation (Par. a,b)

[12/TIA968] ANSI/TIA-968-A (2003)
Telephone Terminal Equipment, Technical Requirements for Connection of Terminal Equipment to the Telephone Network

[12/TIA968a] ANSI/TIA-968-A-1 (2003)
Telephone Terminal Equipment, Technical Requirements for Connection of Terminal Equipment to the Telephone Network - Addendum 1

[12/TIA968b] ANSI/TIA-968-A-2 (2004)
Telephone Terminal Equipment, Technical Requirements for Connection of Terminal Equipment to the Telephone Network - Addendum 2

[12/TIA968c] ANSI/TIA-968-A-3 (2005)
Telephone Terminal Equipment, Technical Requirements for Connection of Terminal Equipment to the Telephone Network - Addendum 3

Return to NVLAP Program Listing


Return to top of page NVLAP Home | Accredited Laboratories | Fields of Accreditation | Publications/Applications |
Mutual Recognition Arrangements | Assessor Resources | Contact NVLAP
Return to top of page

For questions concerning the National Voluntary Laboratory Accreditation Program, contact us:

National Voluntary Laboratory Accreditation Program, Standards Services Division, NIST, 100 Bureau Drive, Stop 2140, Gaithersburg, MD 20899-2140
Phone: (301) 975-4016, Fax: (301) 926-2884, Email: NVLAP@nist.gov

Date created: July 26, 2002
Last Updated: January 8, 2009

Privacy Statement / Security Notice / Accessibility Statement | Disclaimer | FOIA