Jump to main content.


SPLIT DECISION SC

TECHNICAL PRODUCT BULLETIN #SW-22
USEPA, OIL PROGRAM CENTER
ORIGINAL LISTING DATE: NOVEMBER 12, 1998
"SPLIT DECISION SC" (formerly SPLIT DECISION)
(a/k/a CLEAN SPLIT)

I. NAME, BRAND, OR TRADEMARK
SPLIT DECISION SC
Type of Product: Surface Washing Agent (Water Based)

II. NAME, ADDRESS, AND TELEPHONE NUMBER OF MANUFACTURER/CONTACT
Mantek
Division of NCH Corporation
P.O. Box 660196
Dallas, TX 75266-0196
Phone: (972) 438-0202
Phone: (800) 527-9919 ext. 2020
(Mr. George Zimmerman)

III. NAME, ADDRESS, AND TELEPHONE NUMBER OF PRIMARY DISTRIBUTORS
For SPLIT DECISION SC:
Mantek
Division of NCH Corporation
P.O. Box 660196
Dallas, TX 75266-0196
Phone: (972) 438-0202
Phone: (800) 527-9919 ext. 2020
(Mr. George Zimmerman)

For DUO-SPLIT:
Chemsearch
Division of NCH Corporation
Irving, TX 75015
Phone: (972) 438-0202
Phone: (800) 527-9919 ext. 2020
(Mr. George Zimmerman)

For CLEAN SPLIT:
Certified Laboratories
Division of NCH Corporation
P.O. Box 2493
Ft. Worth, TX 76113-2493
Phone: (972) 438-0202
Phone: (800) 527-9919 ext. 2020
(Mr. George Zimmerman)

IV. SPECIAL HANDLING AND WORKER PRECAUTIONS FOR STORAGE AND FIELD APPLICATION
1. Flammability:
Not flammable
2. Ventilation:
Not required
3. Skin and eye contact; protective clothing; treatment in case of contact: SPLIT DECISION SC is not aggressive to skin and will not cause irritation in the majority of users. Avoid contact with eyes, irritation may result. Wear safety glasses with side shields if the method of use presents the likelihood of eye contact. No special precautions or additional protective equipment are required during handling or use.
4.a. Maximum storage temperature: 140ºF
4.b. Minimum storage temperature: 27ºF
4.c. Optimum storage temperature range: 32-140ºF
4.d. Temperatures of phase separations and chemical changes: SPLIT DECISION SC is stable and phase separation will not occur at temperatures within the above storage range. Repetitive freeze/thaw cycles may cause stratification. This stratification is readily dispersed by minimal mixing.

V. SHELF LIFE
The recommended shelf life is one year.

VI. RECOMMENDED APPLICATION PROCEDURE
1. Application Method:
Spray on oily surface. SPLIT DECISION SC forms a loose emulsion with oil that separates within seconds. Oil displaced from surface can be skimmed from the rinse water or absorbed with an oil absorbent.
2. Concentration/Application Rate:
For heavy oil apply at a concentration of 1 part SPLIT DECISION SC to 3 parts water. For lighter oil on non-porous substrates use at up to 1 part SPLIT DECISION SC to 30 parts water. For application by hot water pressure washers or steam cleaner, SPLIT DECISION SC may be diluted with as much as 50 parts water.
3. Conditions for Use:
Effective in fresh water, estuarine, and marine environments at normal climatic temperatures. SPLIT DECISION SC contains no known EPA Priority Pollutants.

VII. TOXICIY AND EFFECTIVENESS
a. Toxicity:
Material Tested Species LC50 (ppm)
Split Decision Menidia beryllina
Mysidopsis bahia
8.27 96-hr
8.20 48-hr
 
No. 2 Fuel Oil Menidia beryllina
Mysidopsis bahia
12.26 96-hr
4.30 48-hr
 
Split Decision SC & No. 2 Fuel Oil (1:10) Menidia beryllina
Mysidopsis bahia
0.25 96-hr
2.06 48-hr
 
Reference Toxicant (DSS) Menidia beryllina
Mysidopsis bahia
13.80 96-hr
22.20 48-hr
 
b. Effectiveness:
NA

VIII. MICROBIOLOGICAL ANALYSIS
NA

IX. PHYSICAL PROPERTIES
1. Flash Point: None
2. Pour Point: N/A
3. Viscosity: 20 cps - Brookfield #1 spindle @ 20 rpm at 73ºF
4. Specific Gravity: 1.075 at 73ºF
5. pH: 7.0
6. Surface Active Agents: Confidential
7. Solvents: Water
8. Additives: Confidential
9. Solubility in Water: Complete

X. ANALYSIS FOR HEAVY METALS, CYANIDE, AND CHLORINATED HYDROCARBONS
Compound Concentration (ppm)
Arsenic < 0.05
Cadmium < 0.03
Chromium < 0.03
Copper 0.20
Lead < 0.05
Mercury < 0.03
Nickel < 0.03
Zinc 0.08
Cyanide < 0.1
Chlorinated Hydrocarbons < 0.1



Local Navigation