Sec. 264.1065  Reporting requirements.

    (a) A semiannual report shall be submitted by owners and operators 
subject to the requirements of this subpart to the Regional 
Administrator by dates specified by the Regional Administrator. The 
report shall include the following information:
    (1) The Environmental Protection Agency identification number, name, 
and address of the facility.
    (2) For each month during the semiannual reporting period:
    (i) The equipment identification number of each valve for which a 
leak was not repaired as required in Sec. 264.1057(d).
    (ii) The equipment identification number of each pump for which a 
leak was not repaired as required in Sec. 264.1052 (c) and (d)(6).
    (iii) The equipment identification number of each compressor for 
which a leak was not repaired as required in Sec. 264.1053(g).
    (3) Dates of hazardous waste man agement unit shutdowns that 
occurred within the semiannual reporting period.
    (4) For each month during the semiannual reporting period, dates 
when the control device installed as required by Sec. 264.1052, 
264.1053, 264.1054, or 264.1055 exceeded or operated outside of the 
design specifications as defined in Sec. 264.1064(e) and as indicated 
by the control device monitoring required by Sec. 264.1060 and was not 
corrected within 24 hours, the duration and cause of each exceedance, 
and any corrective measures taken.
    (b) If, during the semiannual reporting period, leaks from valves, 
pumps, and compressors are repaired as required in Sec. Sec. 264.1057 
(d), 264.1052 (c) and (d)(6), and 264.1053 (g), respectively, and the 
control device does not exceed or operate outside of the design 
specifications as defined in Sec. 264.1064(e) for more than 24 hours, a 
report to the Regional Administrator is not required.