Sec. 436.22  Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control 
          technology currently available.

    (a) Except as provided in Secs. 125.30 through 125.32, and subject 
to the provisions of paragraphs (b) and (c) of this section, any 
existing point source subject to this subpart shall achieve the 
following effluent limitations representing the degree of effluent 
reduction attainable by the application of the best practicable control 
technology currently available (BPT):

[[Page 351]]

    (1) Discharges of process generated waste water pollutants from 
facilities that recycle waste water for use in processing shall not 
exceed the following limitations:

------------------------------------------------------------------------
                                                Effluent limitations
                                           -----------------------------
                                                        Average of daily
          Effluent characteristic             Maximum     values for 30
                                             for any 1  consecutive days
                                                day     shall not exceed-
                                                                -
------------------------------------------------------------------------
pH........................................       (\1\)             (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.

    (2) Mine dewatering discharges shall not exceed the following 
limitations:

------------------------------------------------------------------------
                                                Effluent limitations
                                           -----------------------------
                                                        Average of daily
          Effluent characteristic             Maximum     values for 30
                                             for any 1  consecutive days
                                                day     shall not exceed-
                                                                -
------------------------------------------------------------------------
pH........................................       (\1\)             (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.

    (b) Any overflow from facilities governed by this subpart shall not 
be subject to the limitations of paragraph (a) of this section if the 
facilities are designed, constructed and maintained to contain or treat 
the volume of waste water which would result from a 10-year 24-hour 
precipitation event.
    (c) In the case of a discharge into receiving waters for which the 
pH, if unaltered by man's activities, is or would be less than 6.0 and 
water quality criteria in water quality standards approved under the Act 
authorize such lower pH, the pH limitations for such discharge may be 
adjusted downward to the pH water quality criterion for the receiving 
waters. In no case shall a pH limitation outside the range 5.0 to 9.0 be 
permitted.

[42 FR 35849, July 12, 1977, as amended at 44 FR 76793, Dec. 28, 1979; 
60 FR 33967, June 29, 1995; 60 FR 35796, July 11, 1995]