text-only page produced automatically by LIFT Text Transcoder Skip all navigation and go to page contentSkip top navigation and go to directorate navigationSkip top navigation and go to page navigation
National Science Foundation Home National Science Foundation - Mathematical & Physical Sciences (MPS)
 
Chemistry (CHE)
design element
CHE Home
About CHE
Funding Opportunities
Awards
News
Events
Discoveries
Publications
Career Opportunities
Chemistry Proposal Window and Deadlines
Become a Chemistry Reviewer
Chemistry Highlights, Publications, and Workshop Reports
See Additional CHE Resources
View CHE Staff
MPS Organizations
Astronomical Sciences (AST)
Chemistry (CHE)
Materials Research (DMR)
Mathematical Sciences (DMS)
Physics (PHY)
Office of Multidisciplinary Activities (OMA)
Proposals and Awards
Proposal and Award Policies and Procedures Guide
  Introduction
Proposal Preparation and Submission
bullet Grant Proposal Guide
  bullet Grants.gov Application Guide
Award and Administration
bullet Award and Administration Guide
Award Conditions
Other Types of Proposals
Merit Review
NSF Outreach
Policy Office
Additional CHE Resources
Image Credits
Other Site Features
Special Reports
Research Overviews
Multimedia Gallery
Classroom Resources
NSF-Wide Investments


Press Release 06-044
Small, Ultra-fast and Ultra-versatile Scanner Takes Chemical Analysis to the Field

Surgical aid, medical diagnostic and bomb sniffer may be all in a day's work for this little machine

The Purdue miniature mass spectrometer can easily be carried with one hand.

The Purdue miniature mass spectrometer can easily be carried with one hand.
Credit and Larger Version

March 16, 2006

Researchers at Purdue University have developed a new, ultra-fast chemical-analysis system, with potential applications that range from sniffing luggage for explosive residues to detecting molecular disease markers in urine samples.

Recently, in fact, the researchers demonstrated that their system can rapidly and accurately detect the boundary between cancerous tissue and healthy tissue in the liver--information that could help surgeons make sure they had removed the entire tumor and spared the normal tissue.

"I wouldn't be surprised if pathologists are using this in operating rooms within two years," said Purdue's R. Graham Cooks, the analytical chemist who heads the research effort.

Cooks and his colleagues describe their work in the March 17 issue of the journal Science.

Much of their funding has been provided by the National Science Foundation and the Office of Naval Research, as well as by Inproteo LLC and Prosolia Inc, two Ind. companies engaged in commercializing technology developed at Purdue.

Cooks' team's overall goal has been to speed up and simplify the use of the mass spectrometer, an analytical device that has long been a laboratory fixture. In earlier work, the team tackled the large size, handling difficulties and expense of conventional mass spectrometers. Those efforts resulted in a portable, shoebox-sized instrument that weighs just 22 pounds (10 kilograms) in its current version, or about 30 times less than a conventional mass spectrometer. Moreover, that weight includes a battery pack that allows the miniaturized instrument to be carried into the field to reach the sample, rather than bringing the sample to the instrument in the lab.

Now, in the work reported in Science, the Purdue team has addressed the limitation that conventional mass spectrometers can analyze only samples that have been specially prepared. Their solution is a wand-like probe that can quickly gather chemical information from ordinary samples out in the open air. Based on a process known as desorption electrospray ionization, or DESI, the probe will essentially blast the molecules off any available surface using a mist of microscopic, ionized water droplets.

"The theme in our lab is, 'Don't mess with chemicals,' meaning we don't undertake the usual chemical separations and manipulations needed for conventional mass spectrometry," says Cooks.

For more details, see the Purdue University news release.

-NSF-

Media Contacts
M. Mitchell Waldrop, NSF (703) 292-7752 mwaldrop@nsf.gov
Emil Venere, Purdue University (765) 494-4709 venere@purdue.edu

Principal Investigators
R. Graham Cooks, Purdue University (765) 494-5263 cooks@purdue.edu

Related Websites
R. Graham Cooks' Web site: http://www.chem.purdue.edu/cooks/rgcooks.html

The National Science Foundation (NSF) is an independent federal agency that supports fundamental research and education across all fields of science and engineering, with an annual budget of $6.06 billion. NSF funds reach all 50 states through grants to over 1,900 universities and institutions. Each year, NSF receives about 45,000 competitive requests for funding, and makes over 11,500 new funding awards. NSF also awards over $400 million in professional and service contracts yearly.

 Get News Updates by Email 

Useful NSF Web Sites:
NSF Home Page: http://www.nsf.gov
NSF News: http://www.nsf.gov/news/
For the News Media: http://www.nsf.gov/news/newsroom.jsp
Science and Engineering Statistics: http://www.nsf.gov/statistics/
Awards Searches: http://www.nsf.gov/awardsearch/

 

Cooks and Ouyang discuss the mini mass spectrometer and its potential applications.
View Video
Cooks and Ouyang discuss the mini mass spectrometer and its potential applications.
Credit and Larger Version

DESI technology can perform a molecular scan of any open surface, such as this backpack.
DESI technology can perform a molecular scan of any open surface, such as this backpack.
Credit and Larger Version



Print this page
Back to Top of page
  Web Policies and Important Links | Privacy | FOIA | Help | Contact NSF | Contact Webmaster | SiteMap  
National Science Foundation Mathematical & Physical Sciences (MPS)
The National Science Foundation, 4201 Wilson Boulevard, Arlington, Virginia 22230, USA
Tel:  (703) 292-5111, FIRS: (800) 877-8339 | TDD: (800) 281-8749
Last Updated:
March 19, 2008
Text Only


Last Updated: March 19, 2008