Abstract: Viruses are recovered and concentrated from water by passage through a positively charged cartridge filter. Following virus elution from the cartridge filter with beef extract and concentration of the beef extract solution, viruses are usually assayed by cell culture. However, cultural methods are too time consuming and expensive for routine use and many of the viruses that cause waterborne disease are either very difficult to culture or cannot be cultured.

Rapid polymerase chain reaction (PCR) methods have been developed to overcome these problems. While PCR methods are rapid and can detect all the virus groups known to cause waterborne disease, the methods have several unique problems that can cause false negative and false positive results. The presence of potent environmental inhibitors of PCR that are co-concentrated along with viruses during sample processing can result in false negative results. In addition, aerosols containing previously amplified products can cause false-positive results. The quality control measures needed to prevent these problems are much more complex than those used in traditional microbiology or chemistry laboratories.

The number and types of environmental inhibitors vary among different water types and even within a single water type. Thus PCR methods must be designed to remove as many inhibitors as possible from different water types without affecting virus recovery. A multiplex PCR method was developed at the U.S. EPA to measure the occurrence of enteroviruses, reoviruses, rotaviruses, hepatitis A virus and Norwalk virus in water. The method uses a celite-based elution/reconcentration procedure. It results in concentrating a portion of the filter eluate by greater than 800 fold while providing a 74% recovery of poliovirus. Although the method was very effective, false negative and positive results still occur. In one study false negative results were observed in 14% of the samples and false positive results in 6%. The method and appropriate quality controls will be described.
spacer
Citation:Fout, G. S. Detection By Pcr of Human Enteric Viruses Concentrated from Large Volumes of Water. Presented at EPA Workshop for Development of Protocols for Reliable Genetic Methods for Viruses for Use in EPA's Drinking Water Program, Cincinnati, OH, January 15-16, 2003.
spacer
spacer
Contact: Mary P. O'Bryant - (919)-541-4871 or obriant.mary@epa.gov
spacer
Division: Microbiological & Chemical Exposure Assessment Division
spacer
Branch: Biohazard Assessment Research Branch
spacer
Product Type: Abstrct/Oral
spacer
Presented: 01/15/2003
spacer
Related Entries:
spacer
Bullet Item Detecting Ccl-Related, Emerging Waterborne Human Viruses and Viral Indicators for Exposure Assessment
spacer Relationship Reason:   A Project of the Product
spacer
spacer
spacer

 

ORD Home | Search EPA | Search NERL | Search EIMS | Contacts | Help

 
Begin Site Footer

EPA Home | Privacy and Security Notice | Contact Us

Last Updated on Monday, October 22, 2007
URL: http://cfpub.epa.gov/ordpubs/nerlpubs/recordisplay.cfm