Sub-Ppb Quantitation and Confirmation of Perchlorate in Drinking Waters Containing High Total Dissolved Solids Using Ion Chromatography With Mass Spectrometric Detection

spacer
spacer
Abstract: Perchlorate (ClO4 -) is a drinking water contaminant originating from the dissolution of the salts of ammonium, potassium, magnesium, or sodium in water. It is used primarily as an oxidant in solid propellant for rockets, missiles, pyrotechnics, as a component in air bag inflators, and in highway safety flares. Based on EPA Information Request Responses and occurrence monitoring, there have been 95 confirmed ClO4 - releases in 25 states and 230 users or manufacturers in 40 states. From accidental releases and improper disposal practices of the past, ClO4 - has become a contaminant in surface and ground waters where it is highly mobile and, due to its chemical stability, persists for decades. The primary human health effect is inhibition of iodide uptake by the thyroid gland. By disrupting thyroid hormone production, ClO4 - interferes with metabolism and can affect brain development in fetuses and children, leading to mental impairment. There is now a need for a method that can confirm and quantify ClO4 - at concentrations lower than what is achievable using ion chromatography with suppressed conductivity detection. Coupled with ion chromatographic separation, mass spectrometry is by far the most promising analytical tool available today for low-level identification and quantitation of ClO4 - in drinking water. In this work, sub-ppb quantitation of ClO4 - in drinking waters using ion chromatography electrospray ionization mass spectrometry (IC-ESI-MS) is demonstrated.

The primary mass of interest for ClO4 - is 99 based on the 75.77% relative abundance of the chlorine-35 isotope. Mass 101 is a secondary mass of interest based on the 24.23% abundance of chlorine-37. In this work we demonstrate the feasibility of using oxygen-18 enriched perchlorate as an internal standard. The greatest benefit of such an internal standard is for the improvement of accuracy in the determination of perchlorate in waters with high total dissolved solids such as sulfate, carbonate and chloride. In the event that ClO4 - is regulated in drinking water or that a second national occurrence survey is conducted, this research will lead to an inherently more specific and sensitive U.S. EPA method than is currently available.
spacer
Citation:Hedrick, E. J., and D. J. Munch. Sub-Ppb Quantitation and Confirmation of Perchlorate in Drinking Waters Containing High Total Dissolved Solids Using Ion Chromatography With Mass Spectrometric Detection. Presented at American Water Works Association Water Quality Technology Conference, Philadelphia, PA, November 02 - 06, 2003.
spacer
spacer
Contact: Mary P. O'Bryant - (919)-541-4871 or obriant.mary@epa.gov
spacer
Division: Microbiological & Chemical Exposure Assessment Division
spacer
Branch: Chemical Exposure Research Branch
spacer
Product Type: Abstrct/Oral
spacer
Presented: 11/02/2006
spacer
Downloads:
spacer
Bullet Item Sub-Ppb Quantitation and Confirmation of Perchlorate in Drinking Waters Containing High Total Dissolved Solids Using Ion Chromatography With Mass Spectrometric Detection
spacer
spacer
Related Entries:
spacer
Bullet Item Method Development for the Low-Level Determination of Perchlorate in Drinking Water
spacer Relationship Reason:   A Project of the Product
spacer
spacer
spacer

 

ORD Home | Search EPA | Search NERL | Search EIMS | Contacts | Help

 
Begin Site Footer

EPA Home | Privacy and Security Notice | Contact Us

Last Updated on Monday, October 22, 2007
URL: http://cfpub.epa.gov/ordpubs/nerlpubs/recordisplay.cfm