Table 4.3 - Vertical Access Current Guidelines: 4.1.3 Accessible Buildings: New Construction. Accessible buildings and facilities shall meet the following minimum requirements: . . . (5) One passenger elevator complying with 4.10 shall serve each level, including mezzanines, in all multi-story buildings and facilities unless exempted below. If more than one elevator is provided, each passenger elevator shall comply with 4.10. . . . Proposed Rule: 206.2.3 Multi-Level Buildings and Facilities. Accessible routes shall connect each level, including mezzanines, in multi-level buildings and facilities. . . . 221.5 Vertical Access. Where wheelchair spaces or designated aisle seats share a common accessible route that includes vertical access by means of elevators or platform lifts, elevators or platform lifts shall be provided in such number, capacity, and speed to provide a level of service equivalent to that provided in the same seating area to patrons who can use stairs or other means of vertical access. Final Revised Guidelines: 206.2.3 Multi-Story Buildings and Facilities. At least one accessible route shall connect each story and mezzanine in multi-story buildings and facilities. . . . 206.6 Elevators. Elevators provided for passengers shall comply with 407. Where multiple elevators are provided, each elevator shall comply with 407 . . . . Model Codes & Standards IBC 2000: Section 1104.4 has an equivalent requirement for accessible routes in multi-story facilities. IBC 2003: Section 1104.4 has an equivalent requirement for accessible routes in multi-story facilities.