Chemical Sampling Information
Aluminum (as Al), Welding Fumes |
Chemical Sampling Information - Table of Contents |
Field Definitions
Analytical Methods
|
General Description
NAME: Aluminum (as Al), Welding Fumes
IMIS: A102
CAS: 7429-90-5
DESCRIPTION:
Solid.
Exposure Limits
ACGIH TLV: 5 mg/m³ TWA
NIOSH REL: 5 mg/m³ TWA
Health Factors
HEALTH EFFECTS: Explosive, Flammable, Safety (No adverse effects encountered when Good Housekeeping Practices
are followed) (HE18)
NIOSH/OSHA/DOE Health Guideline
Monitoring
PRIMARY SAMPLING/ANALYTICAL METHOD (SLC1):
MEDIA: Tared Low Ash Polyvinyl Chloride (LAPVC) filter 5 microns
MAX V: 960 Liters MIN V: 480 Liters MAX F: 2.0 L/min
ANL 1: Gravimetric
REF: 11, 12
CLASS: Fully Validated
MEDIA: Tared Low Ash Polyvinyl Chloride (LAPVC) filter 5 microns
MAX V: 960 Liters MIN V: 480 Liters MAX F: 2.0 L/min
ANL 1: Atomic Absorption Spectroscopy; AAS/Lithium Borate
REF: 2 (OSHA In-house file)
CLASS: Partially Validated
NOTE: Submit as a separate sample. When analysis of a compound is requested, an elemental analysis is performed
and reported as the compound. The analytical method does not distinguished between dusts and fume. If the gross weight of the sample yields
a concentration below the standard for the air contaminant, do not submit the sample to SLTC for analysis.
MEDIA: Mixed Cellulose Ester Filter (MCEF) 0.8 microns
MAX V: 960 Liters MIN V: 480 Liters MAX F: 2.0 L/min
ANL 1: Atomic Absorption Spectroscopy; AAS
REF: 2 (OSHA ID-121)
CLASS: Fully Validated
NOTE: Submit as a separate sample. Since this method cannot be used for samples collected on LAPVC filters, the
industrial hygienist is given the option of using either collection procedure for alpha- Alumina (Aluminum Oxide) samples. LAPVC samples are
only submitted to the laboratory if the PEL is exceeded based on a gravimetric analysis. MCEF samples are submitted to the laboratory without
any weighing of filters in the field.
|
Chemical Sampling Information - Table of Contents
|
|
|
|