Appendix to Subpart F of Part 655--Alternate Method of Determining the 
                 Color of Retroreflective Sign Materials

    1. The FHWA Color Tolerance Charts provide that conventional color 
measuring instruments such as spectrophotometers and tristimulus 
photoelectric colorimeters should not be used for measurement of 
retroreflective material colors and that such materials should be 
evaluated visually using the Color Tolerance Charts and paying strict 
attention to prescribed illumination and viewing conditions.
    2. As an alternate to visual testing, the diffuse day color of 
retroreflective sign material may be determined in accordance with ASTM 
E 97, ``Standard Method of Test for 45-Degree, 0-Degree Directional 
Reflectance of Opaque Specimens by Filter Photometry.'' Geometric 
characteristics must be confined to illumination incident within 10 
degrees of, and centered about, a direction of 45 degrees from the 
perpendicular to the test surface; viewing is within 15 degrees of, and 
centered about, the perpendicular to the test surface. Conditions of 
illumination and observation must not be interchanged.
    3. Standards to be used for reference are the Munsell Papers 
designated in Table 1 or Table II, attached. The papers must be recently 
calibrated on a spectrophotometer. Acceptable test instruments are:
    a. Gardner Multipurpose Reflectometer or Model XL 20 Color 
Difference Meter,
    b. Gardner Model Ac-2a or XL 30 Color Difference Meter,
    c. Meeco Model V Colormaster,
    d. Hunter lab D25 Color Difference Meter, or
    e. Approved equal.
    4. Average performance sheeting is identified as Types I and II 
sheeting and high performance sheeting is identified as Types III and IV 
sheeting in Standard Specifications for Construction of Roads and 
Bridges on Federal Highway Projects \3\ (FP-79, Section 633).
---------------------------------------------------------------------------

    \3\ This document is available for inspection and copying as 
prescribed in 49 CFR part 7, appendix D.

                                  Table I--Color Specification Limits and Reference Standards, Types I and II Sheeting
--------------------------------------------------------------------------------------------------------------------------------------------------------
                                                    Chromaticity coordinates \1\ (corner points)             Reflectance
                                          ---------------------------------------------------------------- limits (percent
                  Color                           1               2               3               4              Y) Y          Reference \3\ standard
                                          ---------------------------------------------------------------------------------       (munsell papers)
                                              x       y       x       y       x       y       x       y    Minium  Maximum
--------------------------------------------------------------------------------------------------------------------------------------------------------
White \2\................................    .305    .290    .350    .342    .321    .361    .276    .308      35       --  6.3Gy 6.77/0.8.
Red......................................    .602    .317    .664    .336    .644    .356    .575    .356       8       12  8.2R 3.78/14.0.
Orange...................................    .535    .375    .607    .393    .582    .417    .535    .399      18       30  2.5YR 5.5/14.0
Brown....................................    .445    .353    .604    .396    .556    .443    .445    .386       4        9  5.OYR 3/6.
Yellow...................................    .482    .450    .532    .465    .505    .494    .475    .485      29       45  1.25Y 6/12.

[[Page 248]]


Green....................................    .130    .369    .180    .391    .155    .460    .107    .439     3.5        9  0.65BG 2.84/8.45.
Blue.....................................    .147    .075    .176    .091    .176    .151    .106    .113     1.0        4  5 8PB 1.32/6.8.
--------------------------------------------------------------------------------------------------------------------------------------------------------
\1\ The four pairs of chromaticity coordinates determine the acceptable color in terms of the CIE 1931 standard colorimetric system measured with
  standard illumination source C.
\2\ Silver white is an acceptable color designation.
\3\ Available from Munsell Color Company. 2441 Calvert Street, Baltimore. Maryland 21218.


                                 Table II--Color Specification Limits and Reference Standards, Types III and IV Sheeting
--------------------------------------------------------------------------------------------------------------------------------------------------------
                                                     Chromaticity Coordinates \1\ (corner points)             Reflectance
                                           ----------------------------------------------------------------     limits
                   Color                           1               2               3               4         (percent Y) Y     Reference \3\ standard
                                           --------------------------------------------------------------------------------       (munsell papers)
                                               x       y       x       y       x       y       x       y     Min.    Max.
--------------------------------------------------------------------------------------------------------------------------------------------------------
White \2\.................................    .303     287    .368    .353    .340    .380    .274    .316      27  ......  5.0PB 7/1.
Red.......................................    .613    .297    .708    .292    .636    .364    .558    .352     2.5      11  7.5R 3/12.
Orange....................................    .550    .360    .630    .370    .581    .418    .516    .394      14      30  2.5YR 5.5/14.
Yellow....................................    .498    .412    .557    .442    .479    .520    .438    .472      15      40  1.25Y 6/12.
Green.....................................    .030    .380    .166    .346    .286    .428    .201    .776       3       8  10G 3/8
Blue......................................    .144    .030    .244    .202    .190    .247    .066    .208       1      10  5.8PB 1.32/6.8.
--------------------------------------------------------------------------------------------------------------------------------------------------------
\1\ The four pairs of chromaticity coordinates determine the acceptable color in terms of the CIE 1931 standard colorimetric system measured with
  standard illumination source C.
\2\ Silver white is an acceptable color designation.
\3\ Available from Munsell Color Company, 2441 Calvert Street, Baltimore, Maryland 21218.