NAME: Direct Blue 2

IMIS: 0373

CAS: 2429-73-4

NIOSH: RTECS QJ6158000; 50639

Exposure Limits
Health Factors

Monitoring

PRIMARY SAMPLING/ANALYTICAL METHOD (SLC1):



MEDIA: Glass Fiber Filter (37 mm)
ANL SOLVENT: Methanol/Water (55/45) and PIC-A
MAX V: 100 Liters   MAX F: 1.0 L/min
ANL 1: High Performance Liquid Chromatography; HPLC/UV/VIS
REF: 2 (OSHA In-House File)
CLASS: Partially Validated

COND: Extraction with mobile phase; Zorbax ODS; 55% methanol 45% water; 0.005 M TBAP; 1.1 mL/min; UV det: 546, 436; Retention time, 20 min DL 8.7 ng/inj; extraction eff. 100%; C/P JML 8/82

WIPE:

Yes, with Glass Fiber Filter.

BULK METHOD:

For any dye analysis, a bulk sample of the dye must be sent to the SLCAL. Limit the amount of bulk submitted to one gram or approx. one mL.


Revision Date: 08/24/1992