Chemical Sampling Information
o-Dianisidine-Based Dyes
 Field Definitions
 Analytical Methods
General Description

NAME: o-Dianisidine-Based Dyes

IMIS: D116

CAS: 119-90-4

Exposure Limits

NIOSH REL: Carcinogen-Lowest Feasible Concentration

Health Factors


Monitoring

PRIMARY SAMPLING/ANALYTICAL METHOD (SLC1):



MEDIA: Polytetrafluoroethylene Filter 5 micron
MAX V: 500 Liters   MAX F: 3.0 L/min
ANL 1: High Performance Liquid Chromatography; HPLC/UL47.
REF: 1 (NIOSH 5013)
CLASS: Fully Validated
NOTE: This method does not differentiate between different o-Dianisidine Dyes. Protect samples from heat & light.

MEDIA: Glass Fiber Filter (37 mm)
MAX V: 100 Liters   MAX F: 1 L/min
ANL 1: High performance liquid chromatography; HPLC/UV/Visible
REF: 2 (OSHA In-House File)
CLASS: Not Validated
NOTE: This method differentiates between different o-dianisidine based dyes. See individual dye of interest. Protect samples from heat & light.

COND: Column: C18 Mobile Phase: Detector Wavelength: 280nm Detection Limit: 20.4ug/sample

WIPE:

Yes, with Glass Fiber Filter.

BULK METHOD:

For any dye analysis, a bulk sample of the dye must be sent to the SLCAL. Limit the amount of bulk submitted to one gram or approx. one mL.


Revision Date: 08/24/1992
* All Trademarks are the property of their respective owners.
 