Department of Labor Seal photos representing the workforce - digital imagery© copyright 2001 photodisc, inc.
Department of Labor Seal www.osha.gov  [skip navigational links] Search    Advanced Search | A-Z Index
Chemical Sampling Information
Carbonyl Fluoride
 Field Definitions
 Analytical Methods
 Health Guidelines
General Description

NAME: Carbonyl Fluoride

IMIS: C105

CAS: 353-50-4

Exposure Limits

ACGIH TLV: 2 ppm, 5.4 mg/m3 TWA; 5 ppm, 13 mg/m3 STEL

NIOSH REL: 2 ppm TWA; 5 ppm STEL

Health Factors

Monitoring

PRIMARY SAMPLING/ANALYTICAL METHOD (SLC1):



MEDIA: Midget Fritted Glass Bubbler containing 10 mL 0.1 N NaOH
MAX V: 480 Liters   MAX F: 2.0 L/min (TWA)
MAX V: 30 Liters   MAX F: 2.0 L/min (STEL)
ANL 1: Ion Specific Electrode; ISE
REF: 2 (OSHA In-House file)
CLASS: Not Validated
NOTE: Submit as a separate sample; analyte hydrolyzes instantly to fluoride in water. Analysis is for total F-. Proposed method + follows OSHA method ID-110.

WIPE:

No


Revision Date: 01/15/1993
* All Trademarks are the property of their respective owners.
 