Ethylene Chlorohydrin
 Field Definitions
 Analytical Methods
 Health Guidelines
General Description

NAME: Ethylene Chlorohydrin

SYNONYM(s): 2-Chloroethanol; 2-Chloroethyl alcohol

IMIS: 1120

CAS: 107-07-3

NIOSH: RTECS KK0875000; 34300

DOT: UN1135 Flammable Liquid, Poison

DESCRIPTION:

Colorless liquid with an ether-like odor.
MW: 81
BP: 266 F
VP: 5 mm
MP: -81 F

INCOM: Strong oxidizers and caustics

Exposure Limits

OSHA GENERAL INDUSTRY PEL: 5 ppm, 16 mg/m3 (Skin)

OSHA CONSTRUCTION INDUSTRY PEL: 5 ppm, 16 mg/m3 TWA (Skin)

ACGIH TLV: 1 ppm, 3.3 mg/m3 Ceiling (Skin); Appendix A4 (Not Classifiable as a Human Carcinogen)

NIOSH REL: 1 ppm Ceiling (Skin)

Health Factors

SYMPTOM(s): Mucous membrane irritation; nausea, vomiting; vertigo, incoordination; numbness; vision disturbance; headaches; thirst; delirium; low blood pressure; collapse, shock, coma

HEALTH EFFECTS: Acute Toxicity (HE4); Mutagen (HE2) Chronic toxicity liver, kidney, skin, and lungs (HE3)

ORGAN: Respiration system, liver, kidneys, CNS, skin, CVS

Monitoring

PRIMARY SAMPLING/ANALYTICAL METHOD (SLC1):



MEDIA: Petroleum Base Charcoal Tube (100/50 mg sections, 20/40 mesh)
ANL SOLVENT: (95:5) Carbon Disulfide/Isopropanol
MAX V: 35 Liters   MAX F: 0.2 L/min (TWA)
MIN T: 15 Minutes   MAX F: 0.2 L/min (Ceiling)
ANL 1: Gas Chromatography; GC/FID
REF: 1 (NIOSH 2513)
SAE: 0.12
CLASS: Fully Validated
NOTE: Submit as a separate sample.

SECONDARY SAMPLING/ANALYTICAL METHOD (SAM2):


DEVICE: Instrumentation COMPANY: Infrared Spectrophotometer
PART #: MIRAN 1A & 1B RANGE: 0.2 ppm @ 9.3 um
CLASS: Mfg

WIPE:

Wipe with charcoal pad, seal in glass vial for shipment.


Revision Date: 12/08/1998
* All Trademarks are the property of their respective owners.
 
Back to TopBack to Top www.osha.gov www.dol.gov

Contact Us | Freedom of Information Act | Customer Survey
Privacy and Security Statement | Disclaimers
Occupational Safety & Health Administration
200 Constitution Avenue, NW
Washington, DC 20210