<<< Back to Sampling and Analytical Methods |
Printing Instructions
|
For problems with accessibility in using figures, illustrations and PDF in
this method, please contact
the SLTC at (801) 233-4900. These procedures were designed and tested for
internal use by OSHA personnel.
Mention of any company name or commercial product does not constitute
endorsement by OSHA. |
Evaluation Guidelines for Surface Sampling Methods
[196 KB
PDF, 23 pages]
|
Applied Industrial Hygiene Chemistry Team
Program Support Division
and
Methods Development Team
Industrial Hygiene Chemistry Division
OSHA Salt Lake Technical Center
Sandy UT 84070-6406
|
The following evaluation guidelines were developed to provide chemists with a uniform and practical means for
evaluating surface sampling methods with regards to sampling media, sampling techniques, and sample
preparation for analysis. These guidelines are intended to evaluate only the sampling and other procedures that
differ from existing air sampling methods and are not intended to re-evaluate analytical procedures. Samples
will be analyzed using procedures found in existing validated OSHA methods or other recognized and accepted
analytical procedures. These guidelines specify required laboratory tests, statistical calculations, criteria for
acceptance, and provide an outline for written reports. The overall goal of these guidelines is to provide surface
sampling methods specifically suited to OSHA needs, whose credibility can be clearly defended with evaluation
data.
These guidelines were adapted from the OSHA SLTC "Evaluation Guidelines For Air Sampling Methods Utilizing
Chromatographic Analysis"1 and "Evaluation Guidelines For Air Sampling Methods Utilizing Spectroscopic
Analysis"2, which set the criteria for SLTC methods evaluation protocol. All of these guidelines are open to
examination by the chemists who are using them and any other interested parties. Refinements will be made
as needed.
Techniques related to wipe sampling, using direct reading instruments or colorimetric means, might be
investigated. When promising, these techniques may be developed into separate validated methods. A direct
reading or colorimetric method will be evaluated following pertinent established protocols. Evaluated direct
reading or colorimetric methods may become an appendix to the related surface sampling method, or
referenced to it in some other manner.
Skin dosimetry techniques may provide desirable information that is not obtainable from skin wipe techniques.
When applicable skin dosimetry techniques are available, they may be investigated. If a skin dosimetry method
is developed, it should be evaluated according to an appropriate protocol. Such a method may be referenced
to the related surface sampling method.
EVALUATION GUIDELINES
I. Preliminary Considerations
A. Review literature and consult appropriate sources for information on the following:
Related surface sampling techniques
Related colorimetric or direct reading instruments
Toxic effects
Exposure levels (i.e., NIOSH recommendations, other government standards, industry standard or
recognized industrial hygiene literature)
Workplace exposure (what industries and how many people involved, typical routes of exposure (i.e.,
ingestion, skin absorption)
Biological monitoring techniques
Physical properties and other descriptive information
B. Determine the analyte concentration at which the evaluation will be performed. This value shall be known
as the target concentration and will be based on a review of pertinent literature, industry standards, or
other government standards when possible.
C. Select an existing analytical method to be used in evaluating the sampling medium and technique. This
will usually be the method used to analyze air samples.
D. Select a promising sampling medium with which to begin the evaluation. DURX 670 (10×10 cm polyester
and cellulose), Pro-Wipe 880 (20×25 cm polypropylene), Dissolving (Ghost) Wipes (12×12 cm cross
linked polyvinyl alcohol) and AlphaWipe (23×23 cm polyester) clean room wipers are typical candidates.
In some instances the wipes available from the supplier are too large to be useful and will need to be cut
to a smaller size. If this is the case, select a cutting tool that will not introduce significant interferences.
Wipe media in a size range of 7×7 cm to 10×10 cm are desirable.
E. Some compounds are highly reactive or unstable and will need to be treated with a stabilizing reagent
immediately after sampling. After sampling, the media will be placed in vials containing a solution of the
reagent required for these compounds.
F. Charcoal impregnated disks (such as are used in 3M diffusive samplers) will be the first choice for volatile
organic solvents. Care must be taken that these media remain hermetically sealed until used and also
resealed after sampling, as they will adsorb contaminants from the atmosphere by diffusion.
II. Sampling Procedure
The evaluation guidelines address the evaluation of surface sampling media (clean room wipes, glass fiber
filters and charcoal impregnated pads) and modifications of the surface sampling
method. Surface sampling techniques for some contaminants may require
utilizing reactive reagents and, therefore, may require slight modification for adequate evaluation.
A. Surface sampler removal efficiency
1. The surface sampler removal efficiency refers to the ability of the wipe filter (or other medium) to
absorb or otherwise capture surface contaminants when the medium is moved across a surface under
firm pressure.
2. An ideal surface is one that is extremely smooth and non-porous. A glass plate or
PTFE-coated surface will approach this ideal.
3. The contaminant will be introduced onto a glass or PTFE-coated surface at the target concentration
(micrograms per 100 cubic centimeters). This implies that a template or other means of measuring
the area of the surface must be used. One technique that has been used
is to draw a 10 cm × 10
cm square with a marker on the reverse side of a glass plate.
4. The contaminant need not be uniformly distributed within the confines of the test area. Often the
contaminant will have to be in solution with an appropriate solvent and delivered with a micro-syringe
or micropipette onto the surface to achieve the desired surface contamination concentration.
5. If the contaminant being tested is delivered in solution onto the surface, allow the solvent to totally
evaporate before proceeding. If the contaminant being tested is a volatile organic, be prepared to
proceed as rapidly as possible. A portion of the volatile contaminant will be lost due to evaporation.
This step will be performed in an area that has proper ventilation (i.e., an exhaust hood).
6. Wear the appropriate protective gloves and change them before each subsequent test.
7. Prepare the sampling medium if required. The sampling medium will be moistened with deionized
water for investigating the removal efficiency of the medium for metals or metal compounds from
surfaces. Prepare the sampling medium by wetting with deionized water or isopropanol (or mixture)
for investigating the removal efficiency of the medium for non-volatile organic compounds. Some
compounds may react with water or alcohols. In such cases, other appropriate solvents may need
to be selected. Place the medium on the surface and apply firm pressure. To assure that all
portions of the test area are wiped, start at an outside edge and progress toward the center making
concentric squares of decreasing size. Fold the medium with the contaminant side in and repeat.
Fold the medium once again (if possible) with the contaminant side in and place in a labeled vial for
analysis.
8. Repeat removal efficiency tests on other prepared glass or PTFE surfaces to measure reproducibility.
Six tests will be conducted.
9. Removal efficiency will be deemed adequate if ³ 50% of the contaminant that was placed on an ideal
surface was removed and accounted for by analysis. If removal efficiency is < 50%, try using a
different solvent or medium.
B. Extraction efficiency (EE)
1. The EE is the percent of analyte that can be recovered from a spiked surface sampler, and shall be
determined at sample loadings that represent concentrations of the RQL, 0.1, 1, and 10 times the
target concentration. Always try to maintain a constant EE over the widest range of sample loadings
possible through the judicious selection of extraction solvents and extraction techniques.
2. Four samplers shall be liquid spiked (analyte in solution), at each level, with an amount of analyte
equivalent to the RQL, and 0.1, 1, and 10 times the target concentration.
3. For non-volatile analytes, sufficient time should be allowed for the evaporation of solvent used in the
spiking solution from the sampling media.
4. Extract the spiked samples by adding an appropriate amount of solvent to each vial, and agitate for
an adequate time. Transfer an adequate amount of solvent to vials that are appropriate to the
analysis. Analyze the samples to determine the amount of recovered analyte. The analytical
standards shall be prepared with the same microliter syringe or micropipette used in spiking the
media. Two of the samples containing the target concentration amount of analyte shall be resealed
immediately after analysis, the punctured septa of the other target concentration samples shall be
retained. Use these samples for the test described in Step 7.
5. The EE shall be calculated as follows:
|
where |
EE is the extraction efficiency |
|
MR is the mass of analyte recovered |
|
MS is the mass of analyte placed on the medium |
6. An average extraction efficiency >75% is acceptable but >90% is preferred.
7. The stability of extracted samples will be determined by reanalyzing the target concentration
extraction samples one day after the extraction efficiency is determined. Freshly prepared standards
must be used in the reanalysis. The results obtained will determine if restrictions must be placed
on how soon after extraction the samples must be analyzed. Extracted samples shall be considered
stable if the difference between the average EE one day after extraction and the average EE from the
initial determinations is not greater than 10%.
8. If storage instability is detected in Step 7, a time study may be necessary in which extracted
samples are reanalyzed at sufficiently short intervals. These data will be used to determine how long
after extraction (or analysis) a valid analysis (or reanalysis) can be obtained. The criteria for sample
stability shall be the same at that used in Step 7.
C. Analytical method recovery (AMR) (digestion, solubility, matrix effects)
1. Tests shall be conducted to ensure complete digestion of the sample media, solubility of the analyte,
and to reveal any matrix effects (e.g., viscosity) of the digested sample, as compared to standards.
2. Microwave digestion with the acid matrix used to prepare the standards will be the first choice for
sample preparation.
3. Prepare sixteen samples, four samples each spiked on the sampling media at four different
concentrations, preferably at the RQL, 0.1, 1 and 10 times the target. The RQL and 0.1 times the
target concentrations may be made with dilutions of soluble compounds. The higher spikes are usually done by weighing insoluble
forms of the analyte "neat" rather than in solution. It may not be
possible to quantitatively weigh the lower concentrations. This technique is used to test the solubility
of the analyte in conjunction with the medium digestion.
4. Analyze the sixteen samples by the selected analytical procedure within 24 hours.
5. Perform analysis of the data to determine the Analytical Method Recovery (AMR, also known as
analytical bias).
6. The analytical method must be capable of an overall AMR of >75% but >90% is preferred.
7. Seal two of the four target concentration samples after the initial analysis. The remaining two target concentration samples will be
stored in the tubes that are
lightly covered with plastic wrap. Determine the stability of the digested samples by reanalyzing
these four samples 5-7 days after the Analytical Method Recovery was determined. Use a new set
of standards in the reanalysis. The results obtained will determine if restrictions must be placed on
how soon after digestion the samples must be analyzed. Consider digested samples stable if the
difference between the average results 5-7 days after digestion and the average results from the initial
determinations, at the target concentration is not greater than 10% for each sample.
8. If storage instability is detected in Step 7, a time study may be necessary in which digested samples
are reanalyzed at sufficiently short time intervals. Use this data to determine how long after digestion
(or analysis) a valid analysis (or reanalysis) can be performed. Use the criteria for sample stability
in Step 7.
D. Effects of storage
1. Storage effects are studied for a series of spiked samples to determine any significant bias due to
storage.
2. Twenty-one samples shall be prepared by spiking the analyte at the target concentration onto the
sampling medium that has been moistened if required by the sampling procedure.
3. Three samples shall be analyzed on the day they are prepared.
4. Nine samples shall be stored at room temperature in the dark, and the remaining nine samples shall
be stored under refrigeration at a temperature of 4-6°C.
5. Three samples from each set shall be analyzed approximately every fifth day, resulting in a storage
test 15 to 18 days in length.
6. Recovery will be measured from the regression curve obtained by plotting percent recovery (not
corrected for EE or AMR) versus days of storage.
7. A drop in recovery of more than 10% shall be considered a significant uncorrectable bias and must
be avoided. Also, the recovery (not corrected for EE or AMR) must remain above 75%, during
storage. When these conditions are not met, they may be overcome by: use of an alternate
sampling medium, use of reduced temperature storage requirements, or use of time requirements
for completion of the analysis. The preferable goal is the use a convenient sampler without
restrictions on storage conditions, or time requirements for completion of analysis. An attempt to
achieve this goal should be made before temperature restrictions or time requirements are
used.
E. Interferences to the sampling procedure
1. Interferences to the sampling procedure may manifest themselves in such a manner that collection,
retention, recovery or stability of the analyte on the sampler is impaired.3
2. If any substance has the ability to alter the final concentration of analyte found, it can be considered
an interference. An interference can be a modification of the analyte or analyte signal during a
specific portion of the analysis, a reaction with the medium, or an alteration of the collection
efficiency.
3. Alternative sampling media may have to be used if a serious sampling interference is noted and if the
interference can be considered a commonly found substance when sampling for the analyte of
interest.
4. The effects of suspected interferences (if any) shall be determined by analyzing three samples that
have been spiked with the analyte at the target concentration and with the suspected interference
also added at an appropriate concentration. The concentration of any added interferant is determined
in the same manner as the analyte target level was selected (Section I. B.).
5. Tests shall be conducted to determine interference due to contamination of the prepared media. Two
blank wipe sampling media are moistened with the recommended solvent, placed in vials and
analyzed. Two additional samples shall be prepared by wiping the same type of surface that was
used for the removal efficiency test with media (moistened with reagent, if applicable). The surfaces
shall not be spiked with analyte. The samples are analyzed.
III. Overall Procedure
A. Detection Limit of the Overall Procedure
Detection limits, in general, are defined as the amounts (or concentrations) of analyte that give a response (YDL) that is
significantly different (three standard deviations (SBM) from the response (YBM) of an extracted (or digested) medium
blank.
|
where |
SBM is the standard deviation of the medium blank |
|
YDL is the response at the detection limit |
|
YBM is the response of the medium blank |
1. Spectroscopic Methods
The response of a digested blank medium, and also its standard deviation, is usually measurable
using spectroscopic methods. The response of the detection limit can then be determined as three
standard deviations greater than the response of the digested blank medium. Analyze six digested
blank media, and determine the standard deviation of the response. Use equation one to calculate
the response of the detection limit. Calculate the detection limit and report the DLOP in the method
as concentration or mass per sample.
2. Chromatographic Methods
The direct measurement of YBM and SBM in chromatographic methods is typically inconvenient and
difficult because YBM is usually extremely low. Estimates of these parameters can be made with
data obtained from the analysis of a series of spiked samplers whose responses are in the vicinity
of the response of the reagent blank. The regression curve obtained for a plot of instrument versus
concentration of analyte will usually be linear. If it is clearly nonlinear, refer to Burkhart4 for alternate
calculations. Assuming SBM and the precision of data about the curve are similar, the standard error
of estimate for the regression curve can be substituted for SBM in the above equation. The standard
error of estimate of a line is the mathematical equivalent of the standard deviation for tabulated data.
The following calculations derive a formula for the detection limit:
Text Version: Individually subtract each estimated Y from each
corresponding observed Y. Square the result. Sum all the results. Divide
the sum by the difference of n minus k. Determine the square root of
this quotient. The result is SY•X |
where
|
SY·X is the standard error of estimate for the detection
limit |
|
|
Yobs is the observed response |
|
|
Yest is the estimated response from the regression
curve
|
|
|
n is the total number of data points
|
|
|
k equals 2 for a linear regression |
|
At point YDL on the regression curve
|
where |
YDL is the response at the detection limit |
|
LD is the detection limit |
|
A is analytical sensitivity (slope) |
|
YBM is the response of the background |
therefore
Substituting for YDL from Equation 1 gives
Use the following procedure to assure that the concentrations of spiked samplers used to determine
the regression curve will produce responses in the vicinity of the background response:
a. Estimate the background response from a reagent blank. For chromatographic methods, make
the estimate near the elution time of the analyte.
b. Prepare five spiked samplers, in equally spaced intervals, with the highest spiked sampler
producing a signal about ten times the background response.
c. Analyze the five spiked samplers and one blank sampler.
d. Determine the regression line and the standard estimate of error from the data by plotting
response versus mass introduced into the instrument.
e. Calculate the DLOP using equation 2. Report the DLOP in the method as concentration or mass per sample.
B. Reliable Quantitation Limit (RQL)
1. Consider the RQL as the lower limit for precise analytical measurements. For spectroscopic
methods using equation 1, the RQL is determined as ten standard deviations greater than the
response of the medium blank. A sampler spiked at this level will be analyzed and determined to
be the RQL providing the recovery from the sampler is 100 ± 25% of its theoretical value. If the
recovery from this sampler is not 100 ± 25% of its theoretical value, use the chromatographic
methods procedure (III. A. 2.) to determine the RQL. For chromatographic methods, employing the
regression line data used to calculate the DLOP, the RQL is determined with the following formula,
providing the recovery from the sampler which is closest to the RQL, is 100 ± 25% of its theoretical
value.
|
where |
LRQ is the reliable quantitation limit |
|
SY·X is the standard error of estimate for the regression line |
|
A is the analytical sensitivity (slope) |
If the recovery from the closest sampler is not 100 ± 25% of its theoretical value, then the RQL will
be equal to the lowest spiked concentration that is 100 ± 25% of its theoretical value. Determine this
from a plot of recovery versus mass, for inclusion in the method. Additional data points are obtained
by spiking a series of samplers with 2, 3, 4, or 5 times the highest mass spiked for the DLOP.
2. Report the RQL as mass per sample or concentration.
3. Generate a plot of detector response of the RQL for inclusion in the method.
C. Sampling reproducibility
Prepare six surfaces of same type that was used for the removal efficiency test , by spiking them with
the analyte at the target level as described in Section II A. A chemist, other than the one developing the
surface sampling method, will conduct sampling on the surfaces using the technique as described in
Section II A. The samples are analyzed. This test is repeated again with a third chemist performing the
sampling. The results are a measure of the reproducibility of the sampling procedure under laboratory
conditions.
D. Analytical reproducibility
Prepare six samples at the target concentration in the same manner as the extraction efficiency test
(or in the same manner as the digestion, solubility, matrix effects test, if appropriate). Submit them to
the SLTC for analysis. Include a draft copy of the procedure for analyst instructions. Relying on the draft
copy for instructions, the chemist will analyze the samples. If the samples are stored before analysis,
the conditions under which they are stored should correspond to the recommended storage conditions
of the method.
E. Qualitative analysis
The ability to confirm the presence or concentration of an analyte by a technique that is different than
the one used to perform the analysis is desirable. There is a higher degree of confidence in the accuracy
of the results of critical samples when these results can be confirmed by some other means. Alternate
analysis to detect the presence of the analyte of interest will be identified (i.e., GC/MS, LC/MS, ICP/MS,
CE) . Where the techniques and instruments are available, an analysis of the analyte will be performed.
Spectrum and/or other figures and data are prepared for inclusion in the method.
PREPARATION OF WRITTEN REPORTS
Prepare each report in accordance with the following format:
The following format provides a means of reporting data obtained during evaluation of chromatographic sampling
and analytical methods. The cover page is intended as a quick reference that provides basic information. The
backup data section contains tabulated and graphical laboratory data that are referenced throughout the report.
This outline was prepared from the viewpoint of a chromatographic analysis.
All evaluated methods will have the following statement on the cover page:
"Evaluated method. This method has been subjected to the established evaluation procedures of {appropriate
team name} team."
Methods numbered W4000's are reserved for surface contamination methods.
Page Numbering - The numbering of the pages begins with the cover page. Number pages at the bottom,
centered, stating the page number of the total number of pages (i.e., 5 of 40).
Comments are set off with braces "{ }", and are not included in the method.
Text is written in 10 point Arial font with full justification and with no hyphenation
Tabs: Cover page - 2.0 - Method - 0.2, 0.59, 1.12, 1.36
OSHA logo on cover page - size = 0.500", paragraph anchor, 0" horizontal, 0" from top, right margin, wrap
behind text
Tables - 9 point Arial font, 0.02" for left inside margin, right inside margin, top row margin, bottom row margin
Graphs - size = 3.1", paragraph anchor, 0" horizontal, 0" from top, right margin, wrap left, caption is 9 point Arial
font
Table boxes - size = 3.1", paragraph anchor, 0" horizontal, 0" from top, left margin if next to a graph, wrap left
or neither, 9 point Arial font
References will follow as closely as possible the format recommended by the American Chemical Society in
their 1997 edition of "The ACS Style Guide - A Manual for Authors and Editors."
|
{ANALYTE}
{as listed in CFR or ACGIH}
|
|
Method no.: |
W4xxx |
Target concentration: |
____µg/100cm2 |
|
Procedure: |
Samples are collected by using firm hand pressure to move the {tyoe of collection media} across the surface of interest. Samples are extracted {digested} with
____ and anlyzed by ____ using a ____ detector. |
|
Reliable quantitation limit: |
____ µg |
|
Status of method: |
Evaluated method. This method has been subjected to the established evaluation procedures of the Methods Development Team. |
|
____{month year} |
{Chemist}____ |
{Team}
{SLTC Division}
OSHA Salt Lake Technical Center
Salt Lake City Utah 84115-1802 |
1. General Discussion
The backup data section will be referenced throughout the method in the
following manner: "(Section
4.____)". Literature citations will be footnotes.}
1.1 Background
1.1.1 History
{Answer questions as to why this method is needed. Also, obvious questions that may be
raised by knowledgeable readers should be addressed. Keep length to 1.5 pages or less.}
1.1.2 Toxic effects {Select information with a skin exposure emphasis. Include references to
recognized biological monitoring techniques, if available.} (This section is for information only
and should not be taken as the basis of OSHA policy.)
{Cite sources for presented information. If both animal data and human data are presented,
present the animal data first. If the entire section is taken from one reference, the reference
notation can be placed behind the qualifying statement in the heading.}
1.1.3 Workplace exposure
{Report major sources of skin exposure in the workplace and, if available, the size of the
work population that is exposed. If the entire section is taken from one reference, the
reference notation can be placed behind the heading.}
1.1.4 Physical properties and descriptive information. Other properties may be listed.
CAS number: |
____ |
vapor pressure: {kPa (mmHg)} |
____ |
IMIS number: |
____ |
max: |
____ |
molecular weight: |
____ |
flash point: |
____ |
boiling point: |
____ |
odor: |
____ |
melting point: |
____ |
synonyms: |
____ |
appearance: |
____ |
structural formula: |
____ |
specific gravity: |
____ |
solubility: |
____ |
molecular formula: |
____ |
|
|
This method was evaluated according to the OSHA SLTC "Evaluation Guidelines for Surface Sampling
Methods".5 The Guidelines define analytical parameters, specify required laboratory tests, statistical
calculations and acceptance criteria. The analyte surface concentrations throughout this method are based
on the evaluated sampling area and analytical concentration parameters.
1.2 Limit defining parameters
1.2.1 Detection limit of the overall procedure
The detection limit of the overall procedure is ____{mass} per sample. This is the smallest
amount of {analyte} spiked on the wipe sampler that will give a detector a response that is
significantly different from the response of the wipe sampler blank. (Section 4.1 )
1.2.2 Reliable quantitation limit
The reliable quantitation limit is ____{mass} per sample. This is the amount of {analyte}
spiked on the wipe sampler that will give a detector a response that is considered the lower
limit for a precise quantitative measurement. (Section 4.1)
1.2.3 Recovery
The recovery of {analyte} from spiked samples used in a ____-day storage test remained
above ____ % {the lowest point on the regression curve of Figure 4.2.1} when the samples
were stored at ____ ºC. (or if the case requires: The recovery of {analyte} from samples
used in a ____-day storage test remained above 75% for the first ____ days when samples
were stored at ____ ºC.) (Section 4.2)
1.2.4 Surface sampler removal efficiency
The removal efficiency of {name of the media} for {analyte} is %. This was the
percentage of {analyte} that was removed from {specify type of surface that was used (i.e.,
a glass plate surface)} that was spiked at the target concentration. (Section 4.3)
1.2.5 Sampling reproducibility and analytical reproducibility
Six {state the type of surface, i.e., PTFE-coated} surfaces were spiked at the target
concentration. A chemist, other than the one developing the method, conducted sampling
on the {type of surface} surfaces as described in Section 2. The test was repeated with
another chemist performing the sampling. The first chemist was able to achieve a removal
efficiency of ____%. The second chemist was able to achieve a removal efficiency of
____%. (Section 4.5.1)
Six samples spiked at the target concentration by liquid injection were submitted for
analysis by the OSHA Salt Lake Technical Center. The samples were analyzed according
to a draft copy of this procedure after ____ days of storage at ____
ºC. The average
analytical result was ____% of theoretical. (Section 4.5.2)
2. Sampling Procedure
All safety practices that apply to the work area being sampled should be followed. The sampling should
be conducted in such a manner that it will not interfere with work performance or safety.
2.1 Apparatus {Provide general descriptions of the required equipment followed by a description of
specific equipment actually used in the evaluation, if applicable.}
Samples are collected with {description of the wipe sampling media including wetting reagent if any}.
Samples are collected using firm hand pressure to wipe the sampling medium across a surface.
Wear a clean pair of gloves for each sample. The gloves selected are to be resistant to penetration
of the chemical being sampled and any other chemicals expected to be present.
Labeled vials {specify appropriate type}, one for each sample.
2.2 Reagents
Use the format described in Section 3.2.
2.3 Technique {Describe steps involved in media shipment, sample collection, preparation, and sample
shipment.}
Example:
The media are received from the supplier in large packages, often containing 1200 wipes per package.
Wear clean gloves and remove a sufficient number of wipes to perform the sampling. Remember to
include extra wipes to serve as blanks. {In some instances the wipes available from the supplier are
too large to be useful and will need to be cut to a smaller size. If this is the case, select a cutting
tool that will not introduce significant interferences. Wipe media in a size range of 7 ×7 cm to 10 ×10
cm are desirable. Include any information regarding cutting the media to a useful size here, if
pertinent.} Place the wipes in a 5"×7" recloseable polyethylene zipper bag. Place the remaining
wipes in a large recloseable polyethylene zipper bag. The selected wipes can now be shipped or
taken to the workplace for sampling.
Prepare the deionized water {or other reagents} that may be needed to moisten the wipe prior to
sampling. Also prepare any derivatizing or stabilizing reagents that may be needed to be combined
with the wipe sample after sampling.
Prepare a sufficient number of vials, each labeled with a unique number, for the projected sampling
needs. It may be convenient to preload the vials with the appropriate media if no stabilizing reagent
is being used. Wear clean gloves when handling the media. Do not wear powdered gloves.
Prepare a diagram of the area or rooms to be wipe sampled along with the locations of key surfaces.
Wear a new pair of clean gloves for each sample to prevent contamination of future samples as well
as oneself. The gloves selected are to be resistant to penetration of the chemical being sampled and
any other chemicals expected to be present. {___ type} gloves are recommended for sampling
{analyte} based on a review of glove manufacturer's chemical resistivity and degradation information.
Record the sample vial number and the location where the sample is taken. Withdraw the medium
from the vial with your fingers or clean tweezers. Moisten the medium with ____. {If a damp wipe
sample is required.}
Depending on the purpose of the sample, it may be useful to determine the surface loading of the
contamination (e.g., in micrograms of analyte per area). For these samples, it is necessary to record
the area of the surface wiped (e.g., 100 cm2). This would not be necessary for samples taken to
simply show the presence of the contaminant.
Firm pressure should be applied when wiping. Start at the outside edge and progress toward the
center making concentric squares of decreasing size. Fold the medium with the contaminant side
inward and repeat.
Without allowing the medium to come into contact with any other surface, fold the medium with the
exposed side inward. Place the medium in a sample vial, cap and place a corresponding number at
the sample location on the diagram. Include notes with the sketch giving any further description that
may prove useful when evaluating the sample results (e.g., a description of the surface sampled,
such as: pencil, doorknob, safety glasses, lunch table, inside respirator, employee's forehead or right
or left hand, employees names, etc.).
{If this sampling method for this analyte requires the addition of a solvent or stabilizing reagent after
sampling, include the information here.}
Submit at least one blank wipe medium, treated in the same fashion as the wipe samples, but
without wiping.
Record sample location, employees names, surface area (if pertinent), work description, PPE, and
any other necessary information, along with any potential interferences on the OSHA-91A form.
Submit the samples to the OSHA Salt Lake Technical Center together with OSHA-91A forms as soon
as possible after sampling. If delay is unavoidable, store the samples in a refrigerator. Ship any bulk
samples separate from the surface samples.
2.4 Extraction efficiency {or Analytical Method Recovery, as the case may be} (Section 4.4)
It is the responsibility of each analytical laboratory to determine the extraction efficiency {or analytical
method recovery} because the wipe sampling media, internal standard, reagents and laboratory
techniques may be different than the those listed in this evaluation and influence the results.
2.4.1 The mean extraction efficiency {or analytical method recovery} for {analyte} from {name of
wipe sampling media} over the range of {RQL or 0.1} to 10 times the target concentration
(____ to ____ milligrams per sample) was ____%.
2.4.2 Extracted samples remain stable for at least ____ h {or days}.
2.5 Interferences, sampling
Suspected interferences should be reported to the laboratory with submitted samples. {Include any
information and observations here, regarding suspected interferences that have been tested.} (Section
4.6)
3. Analytical Procedure
Adhere to the rules set down in your Chemical Hygiene Plan.6 Avoid skin contact and inhalation of all
chemicals and review all appropriate MSDSs before beginning the analytical procedure.
Analyze the samples using the analytical procedure in Method number
___7.{When possible, use an
existing validated analytical procedure.}
3.1 Apparatus {Provide general descriptions of the required equipment. Follow each general description
with a specific description of equipment actually used in the evaluation.}
Example:
3.1.1 High performance liquid chromatograph equipped with a fluorescence (FL) or an ultraviolet
(UV) detector, manual or automatic injector, gradient flow programmer and chart recorder.
A Waters M-6000A pump, Waters WISP 710B autosampler, Waters 660 solvent
programmer, Schoeffel 970 FL detector, Waters 440 UV detector, and a Houston dual pen
recorder were used in this evaluation.
3.1.2 LC column capable of separating PAHs from any interferences. A 25-cm × 4.6-mm i.d.
DuPont Zorbax ODS (6 µm) column was used during this evaluation.
3.1.3 An electronic integrator, or some other suitable method of measuring detector response.
3.1.4 Vials, 4-mL with PTFE-lined caps.
3.1.5 Volumetric flasks, pipets, and syringes.
3.2 Reagents {Provide general descriptions of the required reagents. Follow each general description
with a description of the specific reagent actually used in the evaluation.}
Example:
3.2.1Acetonitrile (ACN), HPLC grade, lot, manufacturer, manufacturer location.
3.2.2 Water, HPLC grade. A Millipore Milli-Q system was used to prepare the water for this
evaluation.
3.2.3 Benzene, HPLC grade, {etc.}.
3.3 Standard preparation {Describe preparation of standards in general and give an example.}
Example:
3.3.1 A stock standard solution is prepared by dissolving the selected PAHs in benzene. All
dilutions of the stock solutions are made with benzene to arrive at the working range.
3.3.2 Bracket sample concentrations with standard concentrations. If upon analysis, sample
concentrations fall outside the range of prepared standards, prepare and analyze additional
standards to confirm instrument response, or dilute high samples with extraction solvent and
reanalyze the diluted samples.
3.4 Sample preparation {Describe steps involved in preparing samples for analysis.}
Example:
3.4.1 The surface samples should be received in vials, if not, place the samples into scintillation
vials. Pipet 4.0 mL of benzene into each vial and immediately seal the vials with
polytetrafluoroethylene-lined caps.
3.4.2 Shake the vials vigorously several times during the 60 min extraction time.
3.4.3 Etc.
3.5 Analysis
Example:
3.5.1 Analytical conditions {Provide detailed instrument settings, include
chromatogram at the target concentration, and the calibration technique used.} |
|
Figure 3.5.1 Chromatogram obtained at the
target concentration with the recommended conditions. (1 - Compound A; 2 -
Compound B; 3 - Compound C: 4 - Compound D) |
|
Example:
HPLC conditions |
|
column: |
25-cm × 4.6-mm i.d.
stainless steel
column packed with
6- m DuPont
Zorbax ODS |
mobile phase: |
85:15 ACN/water (v/v) |
flow rate: |
1.0 mL/min for 5
min, Curve 10
(flow program) for
5 min to 1.5
mL/min, then
hold for 10 min |
FL detector: |
254 nm excitation 370 nm emission |
UV detector: |
254 nm |
injection size: |
10 µL |
retention time: |
7-15 min |
chromatogram: |
Figure 3.5.1 |
|
Figure 3.5.2 calibration of {analyte}. (Y=38.89X - 65.50) |
3.5.2 An external standard (ESTD) calibration procedure is used to prepare a calibration curve
using at least 2 stock standards from which dilutions are made. The calibration curve is
prepared daily. The samples are bracketed with analytical standards.
3.6 Interferences (analytical)
Example:
3.6.1 Any compound that produces a fluorescence or UV detector response and has a similar
retention time as the PAH's is a potential interference. If any potential interferences were
reported, they should be considered before samples are extracted. Generally,
chromatographic conditions can be altered to separate an interference from the analyte.
3.6.2 When necessary, the identity of an analyte peak may be confirmed with additional analytical
data. Analysis by an alternate HPLC column, absorbance response ratioing, and mass
spectrometry are additional means of identification (Section 4.7).
3.7 Calculations
Example:
The amount of {analyte} per sampler is obtained from the appropriate calibration curve in terms of
micrograms per sample, uncorrected for extraction efficiency. This amount is then adjusted by
subtracting the amount (if any) found on the blank and corrected for extraction efficiency using the
following formula.
|
where |
MS is the mass recovered from the sampled surface (µg) |
|
M is micrograms per sample |
|
MB is the mass found on the blank (µg) |
|
EE is extraction efficiency, in decimal form |
This amount may be expressed as micrograms {analyte} per 100 cm2 if the surface area that was
sampled was provided, by using the following formula.
|
where |
CS is the (µg) of {analyte} per 100cm2 |
|
MS is the mass on the sampled surface (µg) |
|
S is the surface area sampled (cm2) |
|
100 cm2 is one hundred cubic centimeters |
The surface that was sampled may be less ideal (more porous, less smooth) than the surface that
was used to evaluate the removal efficiency of the sampling media. In this circumstance, the media
will remove the surface contaminant less effectively. There may be significant amounts of
contaminant remaining on the surface after sampling. Nevertheless, the amount found in the sample
indicates that at least this amount of {analyte} was present on the
surface.
4. Backup Data {This section contains evaluation data which is referenced in the preceding sections.}
General background information about the determination of detection limits and reproducibility of the overall
procedure is found in the "Evaluation Guidelines for Surface Sampling Methods".8 The Guidelines define
analytical parameters, specific laboratory tests, statistical calculations and acceptance
criteria.
4.1 Detection limit of the overall procedure (DLOP) and reliable quantitation limit (RQL) {Present the test
data in a table, graph and a chromatogram of the RQL. The example is representative of
chromatographic analysis. The DLOP and RQL of spectroscopic analysis may be determined by
calculations based on direct response measurements of digested media blanks. If this is the case,
present the measurements and calculations here.}
Example:
Table 4.1
Detection Limit of the Overall Procedure
|
|
mass per sample
(µg)
|
area counts
(µV-s)
|
|
0
|
0
|
0.841
|
178
|
1.68
|
375
|
2.52
|
696
|
3.36
|
810
|
4.21
|
1150
|
|
The DLOP is measured as mass per sample. Five samplers were spiked with equal descending increments
of analyte, such that the highest sampler loading was ____ µg/sample. This is the amount spiked on a
sampler that would produce a peak approximately 10 times the response of a sample blank. These spiked
samplers, and a sample blank were analyzed with the recommended analytical parameters, and the data
obtained used to calculate the required parameters (standard error of estimate and the slope) for the
calculation of the DLOP. Values of ____ and ____ were obtained for the slope and standard error of estimate, respectively.
The DLOP was calculated to be ____
µg/sample.
The RQL is considered the lower limit for precise quantitative measurements. It is determined from
the regression line parameters obtained for the calculation of the DLOP, providing 75% to 125% of
the analyte is recovered. The RQL is ____ µg per sample. Recovery at this concentration is ____%.
|
|
|
Figure 4.1.1. Plot of data to determine
the DLOP/RQL.
(Y=277X - 75.8) |
|
Figure 4.1.2. Chromatogram of the RQL. 1- {Analyte} |
4.2 Storage tests {Describe the storage tests, including preparation of samples.}
Storage samples were prepared by spiking media with {analyte}. The medium was spiked with the
target concentration of {analyte} and allowed to dry. {If the analyte is a non-volatile compound,
delivered to the surface in solution.} Twenty-one storage samples were prepared. Three samples
were analyzed on the day prepared. Nine of the samples were stored at reduced temperature (4
ºC)
and the other nine were stored in a closed drawer at ambient temperature (about 22
ºC). At 5-day
intervals, three samples were selected from each of the two storage sets and analyzed. Sample
results were not corrected for extraction efficiency.
Table 4.2
Storage Test for {Analyte} |
|
time (days) |
ambient storage
recovery (%) |
refrigerated storage
recovery (%) |
|
0 |
103.5 |
101.6 |
101.9 |
103.5 |
101.6 |
101.9 |
5 |
99.6 |
100.5 |
95.8 |
99.3 |
99.4 |
101.8 |
10 |
95.6 |
96.6 |
99.1 |
98.9 |
99.6 |
97.5 |
15 |
96.5 |
94.5 |
98.8 |
99.3 |
99.5 |
99.1 |
|
|
|
Figure 4.2.1 Ambient storage test for {analyte} |
Figure 4.2.2 Refrigerated storage test for {analyte} |
4.3 Sampler Removal Efficiency
Table 4.3
Sampler Removal Efficiency
Data for {Analyte} on {Surface
Sampler} |
|
theoretical
(µg/surface) |
recovered
(µg/sample) |
recovery
(%) |
|
420.6 |
388.6 |
92.4 |
420.6 |
395.5 |
94.0 |
420.6 |
393.2 |
93.5 |
420.6 |
379.6 |
90.3 |
420.6 |
379.0 |
90.1 |
420.6 |
406.1 |
96.6 |
|
Six surfaces were spiked at the target concentration of {analyte}, ____ µg /100 cm2. Samples were collected from
each surface using the technique described in Section 2.3 and analyzed. The results are shown in Table 4.3.
4.4 Extraction efficiency {or Analytical method recovery} and stability of extracted {digested} samples
The extraction efficiency is dependent on the extraction solvent as well as the internal standard. Other extraction
solvents or internal standards may be used provided that the new extraction solution or internal standard is tested. The new extraction
solvent or internal standard should be tested
as described below. {The analytical method recovery is dependent on the acid used to digest the media and dissolve
the analyte as well as physical characteristics, such as viscosity, of the resulting digestion matrix. Other acids may be used provided
that standards are
prepared in the same acids and concentrations as the prepared samples. The analytical method
recovery of the new acid digestion procedures should be tested as described below.}
4.4.1 Extraction efficiency {Analytical method recovery}
The extraction efficiencies {analytical method recoveries} of {analyte} were determined by
liquid-spiking {surface sampler} with the analyte at the RQL to 10 times the target
concentration {0.1 to10 times the target concentration for acid digested metals} These
samples were stored overnight at ambient temperature and then analyzed. The mean
extraction efficiency {analytical method recovery} over the working range of the RQL {0.1 for
metals} to 10 times the target concentration is ____%.
Table 4.4.1
Extraction Efficiency {Analytical Method Recovery} of {Analyte} from {Surface Sampler} |
|
level |
sample number |
× target concn |
µg per sample |
1 |
2 |
3 |
4 |
mean |
|
RQL |
2 |
99.8 |
97.5 |
99.6 |
101.4 |
99.6 |
0.1 |
5 |
103.5 |
99.5 |
100.6 |
96.6 |
100.1 |
1.0 |
50 |
95.8 |
92.8 |
96.0 |
96.4 |
95.3 |
10.0 |
500 |
96.5 |
94.5 |
97.3 |
89.4 |
94.4 |
|
4.4.2 Stability of extracted {digested} samples
The stability of extracted {digested} samples was investigated by reanalyzing the four target
concentration samples 24 h after initial analysis. {5-7 days for Acid digested metal samples}
After the original analysis was performed, two of the vials were recapped with new septa,
while the remaining two retained their punctured septa. {acid digested samples are stored
in their auto sampler tubes, two are capped and hermetically sealed, the others lightly
covered with plastic wrap} The samples were reanalyzed with fresh standards. The average
percent change was ____% for the samples that were resealed and ____% for those that
were stored (in their auto sampler tubes, lightly covered) with their septa punctured. (The
septum was punctured ____ times for each injection.)
Table 4.4.2
Stability of Extracted {Digested} Samples for {Analyte} |
|
punctured septa replaced {sealed} |
punctured septa retained {lightly covered} |
initial
(%) |
after
one day
{5 days}
(%) |
difference
(%) |
initial
(%) |
after
one day
{5 days}
(%) |
difference
(%) |
|
95.8 |
100.3 |
4.7 |
96.0 |
104.3 |
8.6 |
|
92.8 |
96.5 |
4.0 |
96.4 |
104.2 |
8.1 |
|
4.5 Reproducibility
4.5.1{Describe sampling reproducibility test and present data in Tables 4.5.1.1 and 4.5.1.2.
Specify that the "amount found" is corrected for extraction efficiency.}
Example:
Six {type of surface} were spiked at the target level. A chemist, other than the one
developing the method, conducted the surface sampling following the procedure described
in the sampling procedure (Section 2.). The test was repeated with a third chemist
performing the sampling. Sample results were corrected for extraction efficiency.
Table 4.5.1.1
Sampling Reproducibility
Data for {Analyte} on {Surface
Sampler} |
|
Table 4.5.1.2
Sampling Reproducibility
Data for {Analyte} on {Surface
Sampler} |
|
|
|
theoretical
(µg/surface) |
recovered
(µg/sample) |
recovery
(%) |
|
theoretical
(µg/surface) |
recovered
(µg/sample) |
recovery
(%) |
|
|
|
420.6 |
388.6 |
92.4 |
|
420.6 |
388.6 |
92.4 |
420.6 |
395.5 |
94.0 |
|
420.6 |
395.5 |
94.0 |
420.6 |
393.2 |
93.5 |
|
420.6 |
393.2 |
93.5 |
420.6 |
379.6 |
90.3 |
|
420.6 |
379.6 |
90.3 |
420.6 |
379.0 |
90.1 |
|
420.6 |
379.0 |
90.1 |
420.6 |
406.1 |
96.6 |
|
420.6 |
406.1 |
96.6 |
|
|
|
Table 4.5.2
Analytical Reproducibility
Data for {Analyte} on {Surface
Sampler} |
|
theoretical
(µg/surface) |
recovered
(µg/sample) |
recovery
(%) |
|
420.6 |
388.6 |
92.4 |
420.6 |
395.5 |
94.0 |
420.6 |
393.2 |
93.5 |
420.6 |
379.6 |
90.3 |
420.6 |
379.0 |
90.1 |
420.6 |
406.1 |
96.6 |
|
4.5.2 {Describe analytical reproducibility test and present data in Tables 4.5.2.
Specify that the "amount found" is
corrected for extraction efficiency.}
Example:
Six samples were prepared by spiking
media in the same manner that was
used in the preparation of samples for
the storage study. The samples were
submitted to the OSHA SLTC for
analysis. The samples were analyzed
after being stored for ____ days at
____ ºC. Sample results were
corrected for extraction efficiency.
4.6 Interferences (sampling)
4.6.1 Media
Tests were conducted to determine interference due to contamination of the prepared media.
Two blank wipe sampling media were moistened with the recommended solvent, placed in
vials and analyzed. Two samples were prepared by wiping same type of surface that was
used for the removal efficiency test with media moistened with {reagent} if applicable. The
surfaces were not spiked with analyte. The samples were placed in vials and analyzed. The
results are shown in Table 4.6.1.
Table 4.6.1
Interference to the Analysis of {Analyte}
from the Media or Surface (µg found)
|
|
sample
|
1
|
2
|
mean
|
|
blank
|
0.000
|
0.010
|
0.005
|
from surface
|
0.000
|
0.020
|
0.010
|
|
4.6.2 Tests were conducted to determine the effects of suspected interferences (if any). Three
samplers were spiked with ____ µg {analyte} and also ____
µg {suspected interfering compound}. The samples were analyzed and the results are shown in Table 4.6.2.
Table 4.6.2
Interference to the Analysis of {Analyte},with {interferant
compound} added.
(µg found) |
|
amount of analyte spiked
|
1 |
2 |
3 |
mean |
|
50.0 µg
|
51.1
|
49.7
|
50.0
|
50.2
|
|
|
Figure 4.7 Mass spectrum of {analyte}. |
4.7 Qualitative analysis
{Present alternate chromatographic and GC/MS conditions that will aid in confirming the identity
of the analyte (or derivative) peak. GC/MS or LC/MS may provide the most conclusive
identification and should be addressed in all cases, even if this amounts to an explanation
why it is not possible or not available. Peak ratios and analysis with alternate detectors may
be useful. The format for a mass spectrum is shown in Figure 4.7.}
References
1.
Evaluation Guidelines For Air Sampling Methods Utilizing Chromatographic
Analysis, 1999; analytical
methods, (accessed May 2000).
2.
Evaluation Guidelines for Air Sampling Methods Utilizing Spectroscopic
Analysis.
3. Care must be taken during the evaluation not to
confuse a reactive substance with a potential sampling interference. If a
substance on the surface simply reacts with the analyte of interest and converts
it to another form, the amount of analyte is diminished. However, the amount of
analyte actually available to produce a toxic effect may also be diminished.
Therefore, an equivalence rather that an interference is established between
that collected on the sampling medium and the surface where both the reactive
and analyte coexist. Note that the product of the analyte and the reactive
substance may be more toxic than the original analyte of interest. Sample
stability problems may be enhanced by co-contaminants. Unstable contaminants
that could breakdown to form the analyte of interest would be a positive
interference.
4. Burkhart, A. J. Appl. Ind. Hyg. 1986, 1, 153-155.
5. Lawrence, R. Evaluation Guidelines for Surface Sampling Methods.
US Department of Labor (DOL), OSHA Salt Lake Technical Center (SLTC): Salt
Lake City, UT, 2001.
6.
National Research Council Recommendations Concerning Chemical Hygiene in
Laboratories (Non-Mandatory) - 1910.1450 App A. Code of Federal
Regulations, Part 1910.1450 App A, Title 29, 1998; standards,
(accessed May 2000).
7. {Title of referenced method linked to web page, number, date}
(Example:
Coal Tar Pitch Volatiles (CTPV) Coke Oven Emissions (COE) Selected
Polynuclear Aromatic Hydrocarbons (PAHs). Method 58, 1986;
(accessed May 2000).
8. Lawrence, R. Evaluation Guidelines for Surface Sampling Methods.
US Department of Labor (DOL), OSHA Salt Lake Technical Center (SLTC): Salt
Lake City, UT, 2001.
|
|
|