95114 ACCESSION #: 9504110327 Industrial Valves DRESSER DRESSER VALVE & CONTROLS DIVISION Post Office BOX 1430 Industrial Valve Operation Alexandria, Louisiana 71309-1430 TEL:318/640-2250 TELEX:58-6423 CABLE. DIVID RAPIFAX: 318/640-6222 Page 1 Of 2 April 4, 1995 Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555 Subject: Industrial Valve Operation, Dresser Valve And Controls Division, Dresser Industries, Inc. 10 CFR Part 21 Notification, Dresser Investigation File No. 95-01 Reporting of a noncompliance to a Main Steam Safety Valve that could cause the valve not to perform its safety function. Gentlemen: The following noncompliance has been determined to be reportable within the requirements of 10 CFR Part 21. The noncompliance occurred in a Main Steam Safety Valve owned by Entergy Operations, Inc., Arkansas Nuclear One (ANO), Unit 1. The noncompliance Is the use of a part In a safety valve that was not manufactured to specification requirements. The part was not manufactured nor provided by Dresser Industrial Valve Operation. Noncompliance and Brief History A Dresser main steam safety valve from Entergy Operations, Inc, Arkansas Nuclear One (ANO), Unit 1, was refurbished at Wyle Laboratories, Huntsville, Alabama, In February 1995. This was a Type 3707R safety valve with serial number BM-02978. During the refurbishment, Dresser's service engineer found the following nonconformances: (1) A foreign lower adjusting ring pin was found In the safety valve. The ring pin was not of Dresser manufacture. And was not In conformance with design criteria. The tip of the pin was worn to the point of failure. (2) The seal wire had been cut and stuck back into the seal. And had been re-crimped with regular pliers. Adjusting ring pins are required to be sealed using special pliers that impresses a Dresser Identification Into the seal. (3) The upper adjusting ring was found in a position other than the position previously set by Dresser. CONSOLIDATED o DEWRANCE o HANCOCK o MASONEILAN o NIL-COR Document Control Desk Page 2 of 2 U. S. Nuclear Regulatory Commission Washington, DC 20555 April 4, 1995 Subject: Industrial Valve operation, Dresser valve And Controls Division, Dresser industries, inc. 10 CFR Part 21 Notification, Dresser investigation File No. 95-01 Reporting of a noncompliance to a Main Steam Safety Valve that could cause the valve not to perform Its safety function. Adjusting ring pins are essential to the safety function. if the adjusting ring pin had failed In service, the lower adjusting ring will most likely rotate downward until It stopped on the nozzle threads. At this low position, the safety valve will not attain rated lift and capacity. And the safety valve will not execute Its safety function. Dresser is concerned about other safety valves at Arkansas Nuclear One (ANO). If safety related parts are used that do not meet design criteria, then we question the ability of the valves to execute their safety f unction. Also, the as found position of the upper adjusting ring may have caused the blowdown of the valve be as high as 15%. Report SV-404, Failure Analysis Report 3707R Main Steam Safety Valve, Revision 0, Dated 3/24/95, for valve serial number BM-02978 is included for NRC review and records. Sincerely, J.M. Cooper Executive Vice President & General Manager acting in the behalf of the above R. D. Danzy Vice President, Engineering cc: A. R. Casler R. D. Danzy R. S. Huffman C. E. McDavid J. W. Richardson D. K. Sharma J. P. Watz Attachments Page 1 Industrial Valves DRESSER INDUSTRIAL VALVE OPERATIONS Phone 318-640-2250 Dresser Industries, Inc. Fax: 318-640-6222 P.O. Box 1430 Alexandria, Louisiana 71309-1430 RAPIFAX MESSAGE wpwln\nrcrpt.fax To: Nuclear Regulatory Commission Operations Center Document Control Desk Phone: 301-816-5100 Fax No.:301-816-5151 From: R. D. Danzy Vice President Engineering Phone: 318-640-9001 Fax: 318-640-6175 Attached is a reportable noncompliance. Dresser Report SV-404, Failure Analysis Report 3707R Main Steam Safety Valve, Revision 0, Dated 3/24/95, for valve serial number BM-02978 is being sent separately by mail. *** END OF DOCUMENT ***