Search Options | ||||
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us |
Licensee's General Comments: none
Unplanned Scrams per 7000 Critical Hrs | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Unplanned scrams | 0 | 0 | 1.0 | 0 | 0 | 0 | 0 | 0 |
Critical hours | 2208.0 | 2104.0 | 2137.0 | 2184.0 | 1680.7 | 1875.2 | 2183.0 | 2184.0 |
Indicator value | 0 | 0 | 0.8 | 0.8 | 0.9 | 0.9 | 0 | 0 |
Licensee Comments: none
Unplanned Power Changes per 7000 Critical Hrs | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Unplanned power changes | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Critical hours | 2208.0 | 2104.0 | 2137.0 | 2184.0 | 1680.7 | 1875.2 | 2183.0 | 2184.0 |
Indicator value | 0.9 | 0.9 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Unplanned Scrams with Complications | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Scrams with complications | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |
Indicator value | 0.0 | 0.0 | 0.0 | 0.0 |
Licensee Comments: none
Safety System Functional Failures (PWR) | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Safety System Functional Failures | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Mitigating Systems Performance Index, Emergency AC Power System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | 1.60E-08 | 1.30E-08 | -1.60E-08 | -1.60E-08 | -1.60E-08 | -1.60E-08 | -1.60E-08 | 1.10E-08 |
URI (ΔCDF) | 7.00E-07 | 4.70E-07 | 2.50E-07 | 2.50E-07 | 2.50E-07 | 2.50E-07 | 2.50E-07 | 4.70E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 7.16E-07 | 4.83E-07 | 2.34E-07 | 2.34E-07 | 2.34E-07 | 2.34E-07 | 2.34E-07 | 4.81E-07 |
Licensee Comments: none
Mitigating Systems Performance Index, High Pressure Injection System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | -1.80E-08 | -1.80E-08 | -1.80E-08 | -1.80E-08 | -2.00E-08 | -2.20E-08 | -2.20E-08 | -2.20E-08 |
URI (ΔCDF) | -8.40E-09 | -8.50E-09 | -8.40E-09 | -8.60E-09 | -8.40E-09 | -8.30E-09 | -8.30E-09 | -8.50E-09 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -2.64E-08 | -2.65E-08 | -2.64E-08 | -2.66E-08 | -2.84E-08 | -3.03E-08 | -3.03E-08 | -3.05E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Heat Removal System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | -2.30E-08 | -2.30E-08 | -2.30E-08 | -2.30E-08 | -2.20E-08 | -2.20E-08 | -2.20E-08 | -2.20E-08 |
URI (ΔCDF) | -3.40E-08 | -3.40E-08 | -3.80E-08 | -3.80E-08 | -3.80E-08 | -4.00E-08 | -4.00E-08 | -4.00E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -5.70E-08 | -5.70E-08 | -6.10E-08 | -6.10E-08 | -6.00E-08 | -6.20E-08 | -6.20E-08 | -6.20E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Residual Heat Removal System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | 8.60E-08 | 8.40E-08 | 8.40E-08 | 8.50E-08 | 3.60E-08 | 3.50E-08 | 2.50E-08 | 2.10E-08 |
URI (ΔCDF) | -7.50E-09 | -7.50E-09 | -7.50E-09 | -7.50E-09 | -7.20E-09 | -7.30E-09 | -7.30E-09 | -7.30E-09 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 7.85E-08 | 7.65E-08 | 7.65E-08 | 7.75E-08 | 2.88E-08 | 2.77E-08 | 1.77E-08 | 1.37E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Cooling Water Systems | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | 3.70E-09 | 3.70E-09 | 3.70E-09 | 4.00E-09 | 3.70E-09 | 3.80E-09 | 3.30E-09 | 1.70E-09 |
URI (ΔCDF) | 4.30E-08 | 4.50E-08 | -2.00E-08 | -2.00E-08 | -2.00E-08 | -2.00E-08 | -1.20E-08 | -1.20E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 4.67E-08 | 4.87E-08 | -1.63E-08 | -1.60E-08 | -1.63E-08 | -1.62E-08 | -8.70E-09 | -1.03E-08 |
Licensee Comments: none
Reactor Coolant System Activity | 7/06 | 8/06 | 9/06 | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 |
Maximum activity | 0.000285 | 0.000279 | 0.000310 | 0.000345 | 0.000429 | 0.000542 | 0.000401 | 0.000420 | 0.000410 | 0.000479 | 0.000457 | 0.000462 |
Technical specification limit | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0.1 | 0 | 0 | 0 | 0 | 0 | 0 |
Reactor Coolant System Activity | 7/07 | 8/07 | 9/07 | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 |
Maximum activity | 0.000520 | 0.000518 | 0.000455 | 0.000236 | 0.000244 | 0.000248 | 0.000281 | 0.000280 | 0.000342 | 0.000375 | 0.000377 | 0.000513 |
Technical specification limit | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
Indicator value | 0.1 | 0.1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.1 |
Licensee Comments: none
Reactor Coolant System Leakage | 7/06 | 8/06 | 9/06 | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 |
Maximum leakage | 0.149 | 0.110 | 0.107 | 0.099 | 0.152 | 0.116 | 0.128 | 0.105 | 0.104 | 0.136 | 0.116 | 0.094 |
Technical specification limit | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 |
Indicator value | 1.5 | 1.1 | 1.1 | 1.0 | 1.5 | 1.2 | 1.3 | 1.1 | 1.0 | 1.4 | 1.2 | 0.9 |
Reactor Coolant System Leakage | 7/07 | 8/07 | 9/07 | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 |
Maximum leakage | 0.107 | 0.116 | 0.102 | 0.154 | 0.129 | 0.121 | 0.114 | 0.148 | 0.095 | 0.090 | 0.082 | 0.081 |
Technical specification limit | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 |
Indicator value | 1.1 | 1.2 | 1.0 | 1.5 | 1.3 | 1.2 | 1.1 | 1.5 | 1.0 | 0.9 | 0.8 | 0.8 |
Licensee Comments: none
Drill/Exercise Performance | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Successful opportunities | 21.0 | 59.0 | 46.0 | 22.0 | 31.0 | 47.0 | 24.0 | 10.0 |
Total opportunities | 29.0 | 62.0 | 47.0 | 22.0 | 32.0 | 49.0 | 26.0 | 10.0 |
Indicator value | 93.9% | 94.0% | 94.7% | 94.0% | 94.2% | 93.8% | 93.7% | 93.9% |
Licensee Comments: none
ERO Drill Participation | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Participating Key personnel | 154.0 | 152.0 | 155.0 | 156.0 | 156.0 | 158.0 | 159.0 | 156.0 |
Total Key personnel | 156.0 | 155.0 | 161.0 | 156.0 | 156.0 | 158.0 | 160.0 | 162.0 |
Indicator value | 98.7% | 98.1% | 96.3% | 100.0% | 100.0% | 100.0% | 99.4% | 96.3% |
Licensee Comments: none
Alert & Notification System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Successful siren-tests | 473 | 475 | 476 | 475 | 476 | 476 | 476 | 474 |
Total sirens-tests | 476 | 476 | 476 | 476 | 476 | 476 | 476 | 476 |
Indicator value | 99.4% | 99.6% | 99.6% | 99.7% | 99.9% | 99.9% | 99.9% | 99.9% |
Licensee Comments: none
Occupational Exposure Control Effectiveness | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
High radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Very high radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Unintended exposure occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
RETS/ODCM Radiological Effluent | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
RETS/ODCM occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Action Matrix Summary | Inspection Findings Summary | PI Summary | Reactor Oversight Process
Last Modified: August 4, 2008