[Code of Federal Regulations]

[Title 30, Volume 1]

[Revised as of July 1, 2006]

From the U.S. Government Printing Office via GPO Access

[CITE: 30CFR57.22218]



[Page 410-411]

 

                       TITLE 30--MINERAL RESOURCES

 

  CHAPTER I--MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR

 

PART 57_SAFETY AND HEALTH STANDARDS_UNDERGROUND METAL AND NONMETAL MINES

--Table of Contents

 

   Subpart T_Safety Standards for Methane in Metal and Nonmetal Mines

 

Sec.  57.22218  Seals and stoppings (III, V-A, and V-B mines).



    (a) All seals, and those stoppings that separate main intake from 

main return airways, shall be of substantial construction, except that 

stoppings constructed of brattice materials may be used in face areas.

    (b) Exposed surfaces on the intake side of stoppings constructed of 

combustible materials or foam-type blocks shall be coated with at least 

one inch of construction plaster containing perlite and gypsum; at least 

one inch of expanded vermiculite, Portland cement and limestone; or 

other coatings with



[[Page 411]]



equivalent fire resistance. Stoppings constructed to phenolic foam 

blocks at least 12 inches thick need not be coated for fire resistance. 

All foam-type blocks used for stopping construction shall be solid.

    (c) Exposed surfaces on the fresh air side of seals constructed of 

combustible materials shall be coated with at least one inch of 

construction plaster containing perlite and gypsum; at least one inch of 

expanded vermiculite, Portland cement and limestone; or other coatings 

with equivalent fire resistance. Foam-type blocks shall not be used for 

seals.