Standard Number: | 1926.550 |
January 27, 1988
B. Eugene Walters, Manager Dear Mr. Walters: This is in response to your November 29, 1988, letter requesting interpretation of 29 CFR 1926.550(g)(4)(iv)(B). The new standard requires that "hooks on overhaul ball assemblies, lower load blocks, or other attachment assemblies shall be of a type that can be closed and locked, eliminating the hook opening." We have reviewed the materials you sent to this office. The hook and latch assembly you proposed does not meet this requirement because the "flapper" latch has a gravity lock which could be dislodged allowing the latch to open. In order to meet the requirements of the proposed standard for a positive locking devices, & bolt and nut assembly may be added to the flapper latch by sliding it through the existing hole in the latch. However, this determination should be considered as only a good faith review of materials submitted and does not constitute approval or endorsement of this product by OSHA. Also, alteration or misapplication of an otherwise safe piece of equipment could easily create a hazardous condition beyond the control of the manufacturer. For this reason, the safe use of the equipment can only be determined by the safety and health professionals observing it actually in use under specific conditions. Hopefully, this information is beneficial in your search for appropriate safety equipment for your employees. If you need additional information, call my office at (202) 523-8136.
Sincerely,
|
Standard Interpretations - Table of Contents |
Back to Top | www.osha.gov | www.dol.gov |
Contact Us | Freedom of Information Act | Customer Survey Privacy and Security Statement | Disclaimers |
||
Occupational Safety & Health Administration 200 Constitution Avenue, NW Washington, DC 20210 |