MR Number: H-00-0067

                           NRR DAILY REPORT ITEM
                           GENERIC COMMUNICATIONS



Subject: Issuance of Information Notice 2000-17, Supplement 1

NRC Information Notice 2000-17,Supplement 1: Crack in Weld Area of       
Reactor Coolant System Hot Leg Piping at V. C. Summer, dated November 16,
2000                                                                     
                                                                         
The U.S. Nuclear Regulatory Commission is issuing this information notice
supplement to tell addressees more about the crack-like indication found 
in a weld in the A loop hot leg pipe in the reactor coolant system at the
V. C. Summer Nuclear Station.                                            
                                                                         
Technical contacts: Eric Benner, NRR        Billy Crowley, Region II     
                    301-415- 1171           404-562-4612                 
                    E-mail: ejb1@nrc.gov    E-mail: brc@nrc.gov          
                                                                         
                    William Koo, NRR                                     
                    301-415-2706                                         
                    E-mail: whk@nrc.gov                                  
                                                                         
Accession No. ML003769172                                                
_
REGION III  MORNING REPORT     PAGE  2          NOVEMBER 17, 2000

Licensee/Facility:                     Notification:

Consumers Power Co.                    MR Number: 3-00-0038
Palisades 1                            Date: 11/14/00
Covert,Michigan                        Tel. call from lisencee 11/24/2000 
Dockets: 50-255
PWR/CE                                

Subject: Spent Fuel Assemblies Placed into Storage Casks Before Required 
         5-year Cooling Time.                                            


Discussion:

On November 14, 2000, Consumer's Power Company notified Region III that a
total of eleven spent fuel assemblies (designated L05, L08, L11, and L13 
through L20) had been placed into five spent fuel storage casks at the   
Palisades Plant before undergoing five years of cooling time following   
their discharge from the reactor core. The five year cooling time limit  
is a condition of the Certificate of Compliance (CofC) for the VSC-24    
casks used at Palisades. During the June 1999 - August 1999 spent fuel   
cask loading campaign at Palisades, casks numbered VSC-15 through VSC-19 
were loaded with 24 spent fuel assemblies each. Due to an error in       
recording core discharge dates for the subject eleven assemblies in the  
"L" series, it was believed that they had undergone more than five years'
cooling. In fact, they had been discharged from the reactor slightly more
than four years previous.                                                
                                                                         
At the present time, all the assemblies have cooled for more than five   
years. The distribution of the eleven assemblies among five casks was    
such that no more than three were placed in any one cask. The total heat 
load in the subject assemblies was not more than 1.2 kW each (vs. the    
CofC limit of 1.0 kW), and it appears other assemblies loaded in each    
cask were sufficiently below the limit that no cask exceeded 24 kW. No   
radiation or temperature anomalies were noted during routine monitoring  
since the casks were loaded. Damage to any cask is considered very       
unlikely.                                                                

Regional Action:

Coordinate follow up and any appropriate enforcement with the Spent Fuel 
Project Office (SFPO).                                                   

Contact:  R.B. Landsman              (630)829-9609
          B.L. Jorgensen             (630)829-9615