MAIN PROPULSION (MECHANICAL) 08/31/2007 THE FOLLOWING STATUS CODES MAY BE CIRCLED ON THE FAR RIGHT C- COMPLETE ON IN EFFECT R- REQUIRES FUTHER ACTION NA- NOT APPLICABLE SAFETY REVIEW ITEMS C. MAIN PROPULSION (MECHANICAL) 3MPA1A0 1. ENGINEERING CASUALTY CONTROL MANUAL (A1B0) IS THE ENGINEER'S ORDER BOARDS INSTALLED IN CCS AND IN MAIN CONTROL? 1 REF: GSO 252C.4 C R NA ******************************************************************************** 2. FLEXIBLE HOSE (B5C0) ARE TUBING VICE FLEXHOSES ON FLAMMABLE LIQUID GAUGE LINES? 3 REF: NAVSEA S6430-AE-TED-010 VOL 1 (5.1.4.d) NAVSEADWG 804-1385850 C R NA ******************************************************************************** 3. MAIN DIESEL AND DRIVE (C1A0) ARE ENGINE THROTTLES/CONTROLS LOCKED/SECURED AND A WARNING SIGN IN PLACE INDICATING THE JACKING GEAR IS ENGAGED? 2 REF: NSTM 241-3.4.7 C R NA ******************************************************************************** (C1B0) ARE DIESEL ENGINE CRANKCASE COVERS IN SATISFACTORY CONDITION? 2 REF: MFGR'S TECHNICAL MANUAL NSTM 233-13.2.1.4 C R NA ******************************************************************************** (C1C1) ARE WARNING SIGNS ON THE SIDE OF ENGINE "CAUTION DO NOT OPEN OR REMOVE ENGINE CRANKCASE COVERS OR ACCESS COVERS UNTIL AT LEAST 30 MINUTES HAVE ELAPSED AFTER SHUTDOWN OF AN ENGINE WHEN IT IS KNOWN OR SUSPECTED THAT THERE HAS BEEN AN EXPLOSION, FIRE,OR AN OVERHEATED PART IN THE CRANKCASE"? 3 REF: NSTM 233-13.2.1.5 C R NA ******************************************************************************** (C1D0) IS DIESEL ENGINE FREE OF FUEL OIL LEAKS, WATER LEAKS AND EXCESSIVE LUBE OIL LEAKS? 2 REF: NSTM 233-13.13 MFGR'S TECHNICAL MANUAL C R NA ******************************************************************************** 4. EXPANSION TANKS (C2B0) ARE THE DIESEL ENGINE WATER SYSTEM EXPANSION TANKS PROVIDED WITH AN AIR-BREAK FROM THE POTABLE WATER SYSTEM? 3 REF: GSO 532 B C R NA 5. ENGINE SHUTDOWN (C3A0) ARE REMOTE OPERATED SHUTDOWN DEVICES CLEARLY LABELED? 3 REF: GSO 502 C C R NA ******************************************************************************** (C3B0) ARE REMOTE SHUTDOWN DEVICES PROPERLY GUARDED? 3 REF: GSO 505 B 10 GSO 70 H C R NA ******************************************************************************** (C3C0) *ARE REMOTE SHUTDOWN DEVICES OPERATIVE? 3 REF: GSO 310 I, 502 C C R NA ******************************************************************************** (C3D0) ARE ROPE CABLES SECURED WITH THE PROPER ATTACHMENTS (U-BOLTS) AND ARE CABLES IN GOOD CONDITION? 3 REF: NSTM 613 1.11.5.1 C R NA ******************************************************************************** 6. GOVERNOR AND TRIPS (C4A0) ARE MACHINERY GOVERNORS AND OVERSPEED TRIPS OPERATIONAL? 3 REF: NSTM 233-13.10.1 GSO 310 I C R NA ******************************************************************************** (C4B0) IS LINKAGE FOULED WITH PAINT OR DIRT, AND HAS THE LINKAGE BEEN PROPERLY LUBRICATED? 3 REF: PMS MIP 3112 Q-16 MFGR'S TECHNICAL MANUAL C R NA ******************************************************************************** (C4C0) *ARE LINKAGES BENT, BINDING OR MISSING FASTENERS? 3 REF: MFGR'S TECHNICAL MANUAL PMS MIP 3112 Q-16 C R NA ******************************************************************************** 7. MAIN SHAFTING/SPRING BEARINGS (E1B0) ARE THERMOMETERS INSTALLED? 2 REF: NSTM 244-2.4.3.13 GSO 244B.3 C R NA ******************************************************************************** (E1C0) C R NA ******************************************************************************** (E1E0) *ARE GUARDS PROVIDED AROUND FLANGED JOINTS? 2 REF: GSO 070H C R NA ******************************************************************************** (E1F0) ARE BULKHEAD SEALS IN GOOD MECHANICAL AND MATERIAL CONDITION? 2 REF: GSO 244 B (9) C R NA ******************************************************************************** 8. MAIN SHAFT SEAL/PACKING (E2A0) IS EMERGENCY PACKING SUBASSEMBLE STOWED IN THE VICINITY OF THE STERN TUBE INSTALLED? 2 REF: GSO 244 B8 (2) C R NA ******************************************************************************** (E2B0) ARE COOLING WATER PIPING/VALVES SATISFACTORY? 2 REF: GSO 244 B.8 NSTM 244-6.4 (FIGURE 244-6.12) C R NA ******************************************************************************** (E2C0) ARE GAUGES INSTALLED/CALIBRATED? 2 REF: GSO 504 E,F,G NSTM 504-3.7.1 C R NA ******************************************************************************** (E2E0) *IS THERE A MEANS FOR INFLATING SEAL? 1 REF: GSO 244 B.8 NSTM 244-6.3.3 C R NA ******************************************************************************** (E2F0) IS PMS BEING ACCOMPLISHED ON CO2/N2 BOTTLES FOR SEAL? 2 REF: NSTM 244-6.5.2.5 MIP 2400 C R NA ******************************************************************************** (E2G0) IS THERE AN INSTRUCTION PLATE DESCRIBING THE NORMAL OPERATION OF THE PRIMARY SEAL. 2 REF: GSO 244 B8 C R NA ******************************************************************************** 9. SPECTROGRAPHIC ANALYSIS (F4C0) IS LUBE OIL AND WATER TEST EQUIPMENT AVAILABLE? 3 REF: NSTM 262-5.1.1 C R NA ******************************************************************************** 10. GENERAL SAFETY (I1D0) IS THERE A SHOCK HAZARD WARNING SIGN POSTED AT AUXILIARY BOILER CIRCUIT CONTROL PANEL? 2 REF: GSO 070 H C R NA ******************************************************************************** (I1F0) ARE UPTAKE SPACES IN SATISFACTORY CONDITION? 4 REF: NSTM 221-2.13.8 C R NA ******************************************************************************** (I1I0) ARE MECHANICAL MEANS INSTALLED FOR RAISING THE AUXILIARY STEAM AND HOT WATER BOILERS RELIEF/SAFETY VALVE DISCS OFF THEIR SEATS? 4 REF: NSTM 221-3.2.12 C R NA ******************************************************************************** (I1J0) IS SAFETY VALVE MANUAL LIFTING DEVICE OPERABLE FOR THE BOILER. 1 REF: NSTM 221-3.2.12 C R NA ******************************************************************************** 11. BOTTOM BLOW SYSTEM (I2C0) ARE WARNING PLATES POSTED AT EACH VALVE STATING: "DO NOT OPEN VALVE WHILE BOILERS ARE OPERATING"? 1 REF: GSO 221 N.18 C R NA 12. BOILER GAUGE GLASSES (I3A0) IS NORMAL WATER LEVEL INDICATED ON GAUGE GLASS? 1 REF: NSTM 221-3.4.1 GSO 221K C R NA ******************************************************************************** (I3B0) ARE CHAINS INSTALLED ON GAUGE GLASS CUTOUTS ON VALVES REQUIRING THEM? 4 REF: NSTM 221-3.4.2.9 C R NA ******************************************************************************** (I3C0) C R NA ******************************************************************************** 13. SIGNS AND PLACARDS (I5B0) ARE OPERATION/SAFETY PLACARDS POSTED AT EACH CHEMICAL INJECTION TANK AREA? 4 REF: NSTM 220-27.49 C R NA ******************************************************************************** 14. BOILER WATER TEST AND TREATMENT (I6B0) ARE CHEMICALS STORED PROPERLY? 1 REF: NSTM 220-28.23 C R NA ******************************************************************************** (I6E0) IS FINE WIRE MESH SCREEN INSTALLED IN CHEMICAL INJECTION TANK FUNNEL? 3 REF: NAVSHIPS DWG 803-1385735 GSO 534 B C R NA ******************************************************************************** (I6F0) C R NA