DECK 02/15/2008 THE FOLLOWING STATUS CODES MAY BE CIRCLED ON THE FAR RIGHT C- COMPLETE ON IN EFFECT R- REQUIRES FUTHER ACTION NA- NOT APPLICABLE SAFETY REVIEW ITEMS I. DECK (3DKA1A0) ****************************************************************************** 1. EMERGENCY BILL (A1A0) DOES THE ABANDONSHIP BILL LIST METHODS OF RELEASING LIFEBOATS? REF: OPNAVINST 3120.32C CH6 ART 640 (F) 8. GSO 583G DWG 803-5001024 3 C R NA ******************************************************************************* (A1B0) ARE CAPACITIES AND LOCATIONS OF DESIGNATED LIFEBOATS LISTED? REF: OPNAVINST 3120.32C CH6 ART 640 (F) 7. 4 C R NA ******************************************************************************* (A1C0) DOES THE BILL LIST ABANDONSHIP STATIONS? REF: OPNAVINST 3120.32C CH6 ART 640 (F) 7. 4 c R NA ******************************************************************************* 2. BOAT BILL (A2A0) ARE PROVISIONS IN EFFECT FOR INSPECTING THE WIRE ROPE FOR PROPER SPOOLING ON THE CABLE DRUM PRIOR TO AND DURING HOISTING AND LOWERING? REF: OPNAVINST 5100.19E ART C0402.F 3 C R NA ******************************************************************************* (A2B0) ARE PROVISIONS IN EFFECT FOR INSPECTING SHIPS BOATS (DAILY BOAT REPORT)? (INSPECTION SHALL INCLUDE:ENGINE, HULL, LIGHTS, BOAT GEAR, EMERG EQUPT, AND A TEST OF FOG SIGNAL) REF: OPNAVINST 3120.32C CH 6 ART 630.1.C.(4).(G) 3 C R NA ******************************************************************************* (A2C0) ARE PROVISIONS IN EFFECT TO INSPECT FOR SEA-WORTHINESS CIVILIAN CONTRACTED WATER TAXIS/FERRIES UTILIZED AS LIBERTY LAUNCH/BOAT. REF: OPNAVINST 5100.19E 0405.A 2 C R NA ******************************************************************************* 3. REPLENISHMENT-AT-SEA BILL (A4B0) HAVE CHECKLISTS BEEN TAILORED TO THE SHIP FOR THE FOLLOWING CONTROL STATIONS: DECK, ENGINEERING, SUPPLY, CONREP STATIONS, AND BRIDGE? REF: NWP 4-01.4 APPENDIX D 4 C R NA ******************************************************************************* 4. TOWING BILL (A5B0) DOES TOWING BILL CONTAIN PROVISIONS FOR SECURING THE ANCHOR AND CHAIN PRIOR TO DISCONNECTING THE CHAIN? REF: OPNAVINST 3120.32C CH6 ART 630.22 (F) (I) 3 C R NA ******************************************************************************* (A5C0) DOES THE TOWING BILL LIST PERSONNEL AND EQUIPMENT REQUIREMENTS? REF: OPNAVINST 3120.32C CH6 ART 600 4 C R NA ******************************************************************************* (A5D0) DOES THE TOWING BILL CONTAIN A DIAGRAM OF THE RIGGING ARRANGEMENT? REF: OPNAVINST 3120.32C CH6 ART 600 4 C R NA ******************************************************************************* 5. WORKING OVER THE SIDE / ALOFT (A6A0) ARE POSITIVE MEASURES IN EFFECT TO CONTROL PERSONNEL WORKING OVER THE SIDE; IE, CHECK OFF LIST SIGNED BY OOD? REF: OPNAVINST 5100.19E CHAPTER 8 2 C R NA ******************************************************************************* (A6A1) ARE SUPERVISORY PERSONNEL FAMILIAR WITH CURRENT DIRECTIVES FOR FALL PROTECTION EQUIPTMENT AND PROCEDURES? REF: NAVSEA DTG 011211Z NOV06 UNAUTHORIZED SAFETY HARNESSES COMNAVSAFECEN AFLOAT SAFETY ADVISORY 7-07 NAVSEA DTG 291810Z SEP 06 AUTHORIZED SAFETY HARNESSES ISE ADVISORY 029-07 RECALL OF CLIMBER SAFETY DEVICES AEL 2-330023058 2 C R NA ******************************************************************************* (A6A2) ARE ALL HARNESSES, SAFEY LANYARDS AND WORKING LANYARDS NAVSEA APPROVED FOR SHIPBOARD USE? REF: NAVSEA DTG 011211Z NOV06 UNAUTHORIZED SAFETY HARNESSES COMNAVSAFECEN AFLOAT SAFETY ADVISORY 7-07 NAVSEA DTG 291810Z SEP 06 AUTHORIZED SAFETY HARNESSES ISE ADVISORY 029-07 RECALL OF CLIMBER SAFETY DEVICES AEL 2-330023058 2 C R NA ******************************************************************************* (A6A3) ARE PERSONNEL PQS QUALIFIED TO OPERATE AERIAL PLATFORMS (MAN-LIFT/JLG)? REF: NAVEDTRA 43127(c) WATCHSTATION 311 2 C R NA ******************************************************************************* 6. MAN OVERBOARD/RESCUE & ASSISTANCE BILLS (A8B0) IS THE SAR OFFICER A GRADUATE OF A TYCOM OR HIGHER AUTHORITY RECOGNIZED SAR PLANNING COURSE? IS HE DESIGNATED IN WRITING? REF: OPNAVINST 3130.6C PG 7 PARA 2H. 2 C R NA ******************************************************************************* (A8C0) DOES THE SHIP HAVE ONE OR TWO QUALIFIED RESCUE SWIMMERS AS REQUIRED? (EXCEPT MCM, MHC AND PC. ONLY ONE REQ.) REF: NTTP 3-50.1A 2.2.1 1 C R NA ******************************************************************************* (A8D0) ARE THE SAR SWIMMERS GRADUATES OF THE SURFACE RESCUE SWIMMER SCHOOL? ARE THEY DESIGNATED IN WRITING? REF: OPNAVINST 3130.6C ENCL 22 5 C R NA ******************************************************************************* 7. CRANE BILL (A9A0) DOES THE SHIP HAVE A CRANE CERTIFICATION PROGRAM? ARE THE CRANE OFFICERS, TEST DIRECTORS AND CRANE CERTIFYING OFFICER DESIGNATED IN WRITING BY THE COMMANDING OFFICER? REF: OPNAVINST 3120.32C CH6 ART 600 5 C R NA ******************************************************************************* 8. LIFE PRESERVERS (B1A0) IS THE MATERIAL CONDITION OF STOWAGE LOCKERS SATISFACTORY? REF: MIP’S 5832/003, H-415/003 4 C R NA ******************************************************************************* (B1B0) ARE LOCKERS LABELED TO INDICATE QUANTITY AND TYPES? REF: GSO 602J 4 C R NA ******************************************************************************* (B1C0) DOES RANDOM CHECK OF LIFE PRESERVERS REVEAL UNSATISFACTORY CONDITION? REF: MIP 5832 SERIES NSTM 077 1 C R NA ******************************************************************************* 9. SAFETY HARNESS (B2E0) IS AN MRC EQUIPMENT GUIDE LIST PROVIDED FOR SAFETY HARNESSES? REF: MIP’S 6231/001, 6231/002, 6231/008 4 C R NA ******************************************************************************* (B2F0) ARE PERSONNEL FAMILIAR WITH PROCEDURES AND EQUIPMENT REQUIRED WHEN WORKING ALOFT AND OVER-THE-SIDE? REF: OPNAVINST 5100.19E ART C0803 2 C R NA ******************************************************************************* 10. LIFE BUOYS AND LIGHTS/MARKERS (B3A0) ARE ITEMS INSTALLED AND OPERABLE AT BRIDGE, FANTAIL, MAIN DECK AND UNREP STATIONS? REF: OPNAVINST 5100.19E C0302 I NWP 4-01.4.2.10.1 (9) (14) 2 C R NA ******************************************************************************* (B3B0) ARE LIFE BUOYS MARKED IN BLACK BLOCKED LETTERS WITH THE SHIPS NAME AND HULL NUMBER AND FITTED WITH 2" WIDE REFLECTIVE TAPE? REF: NSTM 077 2.6.2.1 2 C R NA ******************************************************************************* (B3C0) ARE DISTRESS MARKER LIGHTS ATTACHED TO THE RING BUOY WITH FOUR FEET OF 1/4" DIAMETER POLYETHYLENE LINE (NSN 4020-00-710-2074) AND IS THERE A 2" WIDE STRIP OF REFLECTIVE TAPE COMPLETELY AROUND THE LIGHT CASE NEAR THE LENSE? REF: NSTM 077 2.6.2.1 - 2.6.2.2 2 C R NA ******************************************************************************* (B3D0) ARE RING BUOYS WITH RETRIEVING LINE ATTACHED (LENGTH TO SUIT FREEBOARD OF SHIP) AVAILABLE TOPSIDE IN THE QUARTER DECK AREA, TO PERSONNEL WORKING OVER THE SIDE, AND ON PAINT FLOATS ALONG SIDE THE SHIP? REF: NSTM 077 2.6.2.3 2 C R NA ******************************************************************************* 11. SAFETY SIGNS/PLACARDS (B4A0) ARE ABANDONSHIP INSTRUCTION, SAFETY PRECAUTION PLACARDS AND MUSTER LISTS POSTED AT EACH STATION? REF: GSO 602G, 583G DWG 803-5001024 4 C R NA ******************************************************************************* (B4C0) ARE CAPSTAN OPERATING AND SAFETY PLACARDS POSTED EACH STATION? REF: OPNAVINST 5100.19E ART C1304 GSO 602G DWG 805-1640412 4 C R NA ******************************************************************************* (B4E0) ARE MEN WORKING-OVER-THE-SIDE PLACARDS POSTED AT ALL DECK LEVELS PORT & STARBOARD? REF: GSO 602G DWG 805-1640412 3 C R NA ******************************************************************************* (B4G0) ARE TOWING AND BEING TOWED SAFETY PLACARDS POSTED AT FOCSLE & FANTAIL? REF: GSO 602G 3 C R NA ******************************************************************************* (B4I0) ARE SEWING MACHINE SAFETY PLACARDS, AND OPERATING INSTRUCTIONS POSTED? REF: OPNAVINST 5100.19E ART C1304.A19 GSO 602G 5 C R NA ******************************************************************************* (B4J0) ARE GROUND TACKLE SAFETY PLACARDS POSTED? REF: OPNAVINST 5100.19E ART C0602.V 3 C R NA ******************************************************************************* 12. MATERIAL HANDLING EQUIPMENT (C2A0) HAS THE CO/OIC AUTHORIZED, IN WRITING INDIVIDUALS AS QUALIFIED INSTRUCTORS TO PROVIDE MHE OPERATOR TRAINING? REF: NAVSEA SW023-AH-WHM-010, FIFTH REVISION, PARAGRAPH 3-4.2 4 C R NA ******************************************************************************* (C2B0) HAS THE MHE INSTRUCTOR COMPLETED AN APPROVED INSTRUCTOR COURSE? REF: NAVSEA SW023-AH-WHM-010, FIFTH REVISION, PARAGRAPH 3-5A 3 C R NA ******************************************************************************* (C2C0) DOES THE MHE INSTRUCTOR POSSESS AN MHE OPERATOR’S LICENSE? REF: NAVSEA SW023-AH-WHM-010, FIFTH REVISION, PARAGRAPH 3-5B 3 C R NA ******************************************************************************* (C2D0) ARE THE ADMINISTRATIVE CONTROLS IN PLACE TO ENSURE THAT MHE OPERATORS ARE INFORMED OF CHANGES TO REFERENCE MANUALS THAT AFFECT THE SAFETY OF MHE OPERATIONS? REF: NAVSEA SW023-AH-WHM-010, FIFTH REVISION, PARAGRAPH 3-3.2B 3 C R NA ******************************************************************************* (C2E0) HAVE MHE OPERATORS ATTENDED REFRESHER TRAINING AS NECESSARY? REF: NAVSEA SW023-AH-WHM-010, FIFTH REVISION, PARAGRAPH 3-3.3 A THRU 3 C R NA ******************************************************************************* (C2F0) DOES THE MHE OPERATOR’S LICENSE CONTAIN ALL PERTINENT INFORMATION (I.E.; EXPLOSIVE OPERATOR, MEDICAL EXAM)? REF: NAVSEA SW023-AH-WHM-010, REV 5, PARAGRAPH 3-4.1 A,B,C,D. 3 C R NA ******************************************************************************* (C2G0) IS THERE, A DOCUMENTED PROCESS TO RENEW A REVOKED/EXPIRED OPERATOR’S LICENSE? REF: NAVSEA SW023-AH-WHM-010, FIFTH REVISION, PARAGRAPH 3-4.4 AND 3-4.5. 3 C R NA ******************************************************************************* (C2H0) IS A MAINTENANCE HISTORY FILE FOR EACH PIECE OF MHE MAINTAINED? REF: NAVSEA SW023-AH-WHM-010, FIFTH REVISION, PARAGRAPH 6-2, NAVSEA OP 4, EIGHTH REVISION, 3-9.4, NAVSUP PUBLICATION 538, THIRD REVISION, PARAGRAPH 8-3 3 C R NA ******************************************************************************* (C2I0) ARE PRE/POST OPERATIONAL INSPECTIONS CONDUCTED AND RECORDED? REF: NAVSEA SW023-AH-WHM-010, FIFTH REVISION, PARAGRAPH 4-2, G-3, NAVSUP PUBLICATION 538, THIRD REVISION, PARAGRAPH 8-2.1 AND FIGURE 8-1 3 C R NA ******************************************************************************* (C2J0) IS MATERIAL HANDLING EQUIPMENT (INDUSTRIAL TRUCKS) HANDLING EXPLOSIVE ORDNANCE PROPERLY MARKED? REF: NAVSEA OP-4 PARA 3-9.2.4 EIGHTH REVISION NAVSUP PUBLICATION 538 THIRD REVISION 4 C R NA ******************************************************************************* (C2K0) ARE OPERATORS OF (MHE) QUALIFIED & LICENSED? REF: NAVSEA OP 4, EIGHTH REVISION, PARAGRAPH 2-4.4 NAVSEA SW023-AH-WHM-010, FIFTH REVISION, PARAGRAPH 3-3, 3-4. 3 C R NA ******************************************************************************* 13. SIGNS AND PLACARDS (D6B0) ARE REPLENISHMENT AND REFUELING AT SEA SAFETY AND OPERATING INSTRUCTIONS POSTED AT EACH STATION? REF: REF: GSO 570C, 602H 3 C R NA ******************************************************************************* (D6D0) ARE SAFETY AND OPERATING INSTRUCTIONS POSTED FOR THE SLIDING PADEYE AT EACH STATION? REF: GSO 570C, 602H 3 C R NA ******************************************************************************* (D6E0) ARE SAFETY AND OPERATING INSTRUCTIONS POSTED FOR THE WINCH AT EACH STATION? REF: GSO 570C, 602.H 3 C R NA ******************************************************************************* (D6F0) ARE LUBRICATION CHARTS POSTED FOR EACH WINCH? REF: GSO 602H, GSO 570C 5 C R NA ******************************************************************************* 14. DECK COVERING (UNREP) (D7A0) IS NON-SKID PROVIDED ON DECK AROUND ALL REPLENISHMENT EQUIPMENT AND HANDLING AREAS? REF: NWP 4-01.4 2.10.1.13 NSTM 634-2.1.1 GSO 634E OPNAVINST 5100.19E ART C0302.E 4 C R NA ******************************************************************************* 15. REPLENISHMENT AT SEA (D8A0) IS THERE ADEQUATE NIGHT LIGHTING AVAILABLE. REF: OPNAVINST 5100.19E C0302.P 3 C R NA ******************************************************************************* 16. SHACKLES (UNREP) (D9A0) ARE ALL SHACKLES SEIZED AND/OR COTTER PINS IN PLACE AS APPLICABLE? ARE THEY THE CORRECT TYPE? REF: NWP 4-01.4.2.3.3, FIGURE 2-6 3 c R NA ******************************************************************************* 17. CHAIN LOCKER (E1E0) IS GAS FREE CERTIFICATION SAFETY PLACARD "ENTERING VOIDS OR OTHER UNVENTILATED SPACES OR COMPARTMENTS FLOODED WITH CO2" POSTED AT THE ACCESS TO THE CHAIN LOCKER? REF: GSO 602J OPNAVINST 5100.19E B8, C0602G 4 C R NA ****************************************************************************** 18. CHAIN ASSEMBLY (E2B0) ARE ALL DETACHABLE LINKS IN THE SWIVEL SHOT ASSEMBLY PROVIDED WITH CRES HAIRPIN LOCKS/LEAD PLUGS IN PLACE? REF: NSTM 581 PARA 6.2.1.7 FIG 581-6.6 3 C R NA ******************************************************************************* (E2E0) IS DETACHABLE LINK TOOL BOX AVAILABLE/COMPLETE? REF: NSTM 581 PARA 6.2.14 NAVSHIPSDWG 804-840327 4 C R NA ******************************************************************************* (E2F0) IS THE SWIVEL LOCATED INBOARD OF THE FIRST CHAIN STOPPER? REF: NSTM 581 PARA 6.2.9.2 4 C R NA ******************************************************************************* (E2G0) IS THERE A MOORING SHACKLE, DIP ROPE AND CLEAR HAWSE PENDANT ON BOARD? IS THERE A CABLE JACK AVAILABLE FOR USE ON SHIPS WITH 2-3/4 INCH AND LARGER CHAIN? REF: NSTM 581 PARA 6.2.5, 10, 11 AND 12 4 C R NA ******************************************************************************* 19. SOUNDING PLATFORM (E3A0) IS THE SOUNDING PLATFORM (LEADSMAN) AVAILABLE AND IN SATISFACTORY MATERIAL CONDITION? IS A LEAD LINE AVAILABLE? REF: GSO 611G 4 C R NA ******************************************************************************* (E3B0) ARE FORE AND AFT LIFERAILS 38" HIGH? REF: GSO 611G. 4 C R NA ******************************************************************************* (E3C0) ARE OUTBOARD LIFELINES CRES A151 300 SERIES COVERED WITH A PLASTIC COATING? REF: GSO 611G. 4 C R NA ******************************************************************************* 20. ANCHOR WINDLASS (E4B0) ARE THE FOLLOWING PLACARDS AND LABEL PLATES POSTED AND READABLE? 1. SAFETY AND OPERATING INSTRUCTIONS. 2. LUBRICATION CHART. 3. CONTROLS, CLUTCH AND BRAKE. REF: OPNAVINST 5100.19E ART C0602.U.4, GSO 602H 5 C R NA ******************************************************************************* (E4E0) ARE GYPSY OR CAPSTAN HEADS CLEAN AND FREE OF GOUGES, PAINT AND RUST? REF: OPNAVINST 5100.19E ART C0602.U.3.A 5 C R NA ******************************************************************************* 21. GROUND TACKLE APPENDAGES (E6A0) ARE WIRE NET LIFE GRATINGS IN PLACE OVER HAWSE PIPE OPENINGS? REF: GSO 581B OPNAVINST 5100.19E ART C0602.N 5 C R NA ******************************************************************************* (E6B0) ARE GRATING AND COVER SECURING DOGS AND STAPLES INTACT? REF: GSO 581C OPNAVINST 5100.19E ART C0602.N 5 C R NA ******************************************************************************* 22. ANCHOR CHAIN STOPPER (E7B0) IS PMS AND PRESERVATION SATISFACTORY? REF: MIP 5811, 5 C R NA ******************************************************************************* (E7D0) HAVE STOPPERS USED FOR TOWING BEEN MODIFIED TO ACCEPT A LOCKING PLATE AND COTTER PIN? REF: NSTM 581 PARA 2.3.1, 6.2.9 NAVSEADWG S2605-860000 REV E 5 C R NA ******************************************************************************* 23. LINES (F2B0) ARE COGNIZANT PERSONNEL AWARE THAT MANILA LINE 5 YEARS OR OLDER SHALL NOT BE USED FOR CRITICAL OPERATIONS INVOLVING PERSONNEL? REF: NSTM 613 PARA 2.9.1 3 C R NA ******************************************************************************* 24. BOAT SLING (G5A0) IS THE SLING PMS AND MATERIAL CONDITION SATISFACTORY? REF: MIP 5833, 5831 NSTM 583 VOL 1 PARA 7.3 THRU 7.3.5 2 C R NA ******************************************************************************* (G5B0) DO SHACKLES HAVE COTTER PINS IN PLACE? REF: NSTM 583 VOL 1 PARA 7.1.1.1.-7.4.4 MIP 5833 OPNAVINST 5100.19E ART CO402.D, CO4O2.O,C0404W 2 C R NA ******************************************************************************* (G5C0) IS THE WEIGHT TEST LABEL BAND INSTALLED AND IS IT WITHIN 18 MONTHS OF THE LAST TEST DATE? REF: NSTM 583 PARA 7.4 2 C R NA ******************************************************************************* 25. GRIPES, BOAT (G7A0) ARE TAKE UP DEVICES MARKED TO INDICATE LIMIT OF TENSIONING? REF: NSTM 583 Vol II PARA.13.7.2F GSO 583B 4 C R NA ******************************************************************************* (G7B0) ARE GRIPES EQUIPPED WITH QUICK RELEASE FITTINGS (DAVIT STOWAGE)? REF: GSO 583B NSTM 583 VOL II PARA 583-13.7.4.2 FIGURE 583-13-11 4 C R NA ******************************************************************************* (G7C0) IS WIRE PMS AND MATERIAL CONDITION SATISFACTORY? REF: MIP 5831 4 C R NA ******************************************************************************* (G7D0) ARE TURN BUCKLES EQUIPPED WITH LOCK NUTS? REF: NSTM 583 VOL II PARA 583-FIG 13.7.2F, MIP 5831 4 C R NA ******************************************************************************* (G7E0) ARE SHACKLES SEIZED COTTER PINS INSTALLED? REF: MIP 5831 4 C R NA ******************************************************************************* 26. BOAT DAVITS, GENERAL (H1A0) IS AN BI-ANNUAL LOAD TEST CONDUCTED? REF: NSTM 583 VOL II PARA 13.6 MIP 5831 2 C R NA ******************************************************************************* (H1B0) HAS THE PLACED IN SERVICE DATE BEEN ESTABLISHED FOR THE INSTALLED DAVIT WIRE ON THE SLAD DAVIT, HAS IT'S SERVICE LIFE EXPIRED (3 YEARS FROM IN-SERVICE DATE). HAS THE DAVIT WIRE BEEN REPLACE WITH DRAWN GALVANIZED WIRE IAW NAVSEA ISEA 042-07 REF: NSWCCD-SSES ISEA 042-07 1 C R NA ******************************************************************************* (H1C0) ARE PROTECTIVE GUARDS/COVERS INSTALLED OVER TRACKWAYS, SHEAVES AND FALLS EXPOSED IN PERSONNEL WORKING AREAS? REF: OPNAVINST 5100.19E ART C1302 (16) GSO 070H, 583A 1 C R NA ******************************************************************************* (H1D0) IS A LADDER PROVIDED FOR ACCESS TO BOATS/DAVIT HEADS? (AS REQUIRED) REF: GSO 583A, 622C 4 C R NA ******************************************************************************* (H1G0) IS NON-SKID PROVIDED ON DECK, LINE HANDLING AND WORK AREAS? REF: NSTM 634 GSO 634 3 C R NA ******************************************************************************* (H1H0) ARE SAFE HOISTING POSITION STRIPES PAINTED ON ALL DAVITS EXCEPT FIXED OVER HEAD SUSPENDED & SLEWING ARM DAVITS? STRIPES SHALL BE 2" WIDE USUALLY RED IN COLOR (4 STRIPES TOTAL). REF: NSTM 583 VOL II PARA 13.3.2, MIL STD 1310E NAVY 1 C R NA ******************************************************************************* (H1I0) ARE SLEWING ARM POSITION STRIPES PAINTED ON THE DAVIT ARM AND THE FIXED PEDESTAL? STRIPES SHALL BE 2" WIDE AND USUALLY RED. REF: MIL-STD 1310E NAVY NSTM 583 VOL II PARA 13.3.3 5 C R NA ******************************************************************************* 27. GRIPES, DAVIT HEAD PREVENTER (H2A0) ARE GRIPES EQUIPPED WITH QUICK RELEASE FITTINGS? REF: GSO 583D NSTM 583 VOL II PARA 13.2.29, FIGURE 583-9-16 3 C R NA ******************************************************************************* (H2B0) IS WIRE PMS AND MATERIAL CONDITION SATISFACTORY? REF: MIP 5831 3 C R NA ******************************************************************************* (H2C0) ARE TURNBUCKLES EQUIPPED WITH LOCK NUTS? REF: MIP 5831 NSTM 583 VOL II PARA 13.7.2F, FIGURE 583-13-11 4 C R NA ******************************************************************************* (H2D0) ARE SHACKLES SEIZED AND OR COTTER PINS INSTALLED? REF: MIP 5831 NAVSEA DWG 803-5184124 NOTE 10 4 C R NA ******************************************************************************* 28. MANROPES, BOAT DAVITS (H3A0) ARE MONKEY LINES 3-1/2 INCH CIRC PLAITED SPUN POLYESTER, KNOTTED AND, SECURED TO SPANWIRE TO PREVENT SLIPPING (MANILA NYLON AUTH IF INSTALLED IAW DAVIT RIGGING ARRANGEMENT DWG)? REF: GSO 583D NAVSEA DWG 803-5184124 3 C R NA ******************************************************************************* 29. SPAN WIRE, DAVIT HEAD (H6A0) IS THE SPAN WIRE PMS AND MATERIAL CONDITION SATISFACTORY? ARE THE SHACKLES SEIZED OR COTTER PINS INSTALLED? REF: MIP 5831 OPNAVINST 5100.19E C0404W 1 C R NA ******************************************************************************* 30. WINCH, BOAT DAVITS (H7B0) ARE CONTROLLER LABEL PLATES INSTALLED AND READABLE? REF: OPNAVINST 5100.19E ART C0404x1 GSO 583G 2 C R NA ******************************************************************************* (H7C0) IS THE EMERGENCY DISCONNECT SWITCH LABELED, COLORED RED AND OPERABLE? REF: OPNAVINST 5100.19E ART C0104-3 3 C R NA ******************************************************************************* (H7D0) IS PRESERVATION AND MATERIAL CONDITION SATISFACTORY? REF: MIP 5831 OPNAVINST 3120.32C ART 310.C.9 4 C R NA ******************************************************************************* (H7E0) IS THE SPOOLING DEVICE PMS SATISFACTORY? REF: MIP 5831 3 C R NA ******************************************************************************* (H7G0) ARE THE FOLLOWING PLACARDS & LABEL PLATES POSTED & READABLE? 1. SAFETY AND OPERATING INSTRUCTION. 2. LUBRICATION CHART. REF: GSO 583G, 602H OPNAVINST 5100.19H ART C0404X1 5 C R NA ******************************************************************************* 31. BOAT BOOM (H8D0) IS THERE NON-SKID DECK COVERING ON BOOM WALKWAY? REF: NSTM 634 4 C R NA ******************************************************************************* (H8E0) IS THE BOOM LIGHT IN SATISFACTORY CONDITION? REF: GSO 332G 5 C R NA ******************************************************************************* (H8F0) IS THE BONDING STRAP (TYPE I) ATTACHED? REF: MIL-STD 1310 GSO 170C,406 5 C R NA ******************************************************************************* (H8G0) IS THE GOOSE NECK GREASE FITTING IN SATISFACTORY CONDITION? REF: MIP 5831/025 4 C R NA ******************************************************************************* (H8I0) ARE SHACKLE COTTER PINS IN PLACE? REF: MIP 5831/025 4 C R NA ******************************************************************************* (H8J0) ARE TURNBUCKLES EQUIPPED WITH LOCK NUTS IF REQ? REF: 5831/025, SHIPS DWGS 3 C R NA ******************************************************************************* (H8K0) IS TEST DATA PLATE INSTALLED? REF: GSO 602G 4 C R NA ******************************************************************************* 32. SMALL BOAT DECK STOWAGE AND/OR DOLLY (H9C0) ARE DOLLY STOWAGE GRIPES ADEQUATE, MATERIAL CONDITION SATISFACTORY? REF: MIP 5831 GSO 583B 4 C R NA ******************************************************************************* (H9G0) IS THE CRADLE HOIST WIRE AND WINCH PMS AND MATERIAL CONDITION SATISFACTORY? REF: MIP 5831 2 C R NA ******************************************************************************* 33. STOWAGE, ENCAPSULATED (I2A0) ARE SEA PAINTER BITTER ENDS ATTACHED TO SHIP'S STRUCTURE AFT ADJACENT TO THE STOWAGE AND ACCESSIBLE FROM DECK? REF: NSTM 583 PARA 12.9.1.2, 12.10.2.1.2 MIP 5832/004 GSO 583F 3 C R NA ******************************************************************************* (I2C0) IS EACH BOAT IDENTIFIED ON THE OUTSIDE OF THE CONTAINER WITH THE LOCATION OF PACKING FACILITY, MONTH YEAR PACKED AND DATE OF LAST INSPECTION? REF: REF: MIP 5832 4 C R NA ******************************************************************************* (I2D0) ARE OPERATING/RELEASING INSTRUCTION LABEL PLATES POSTED AT EACH STATION? REF: REF: GSO 583G 3 C R NA ******************************************************************************* (I2E0) ARE BRASS SECURING BANDS INTACT? WEAK LINK PROVIDED? REF: NSTM 583 PARA 12.9.2 3 C R NA ******************************************************************************* (I2F0) ARE THE CONTAINERS SECURED WITH 5/16 DIA, 6X37 TYPE 1, CLASS 3, GENERAL PURPOSE, DOUBLE GALVANIZE PLOW STEEL, IWRC FIBER ROPE CORE WITH POLYPROPYLENE COATING OR 5/16 KEVLAR WITH A NYLON JACKETT? IS THE HARDWARE CRES AND PROPERLY SECURED? REF: NSTM 583 PARA 13.10.2.1.1 MIP 5832/004 NAVSEA DWG 803-5001024 NAVSEA DWG 803,6397272,73 OR 75 2 C R NA ******************************************************************************* (I2G0) ARE LASHINGS (1/4 INCH DIAMETER NYLON DOUBLE BRAID CORD MIL-R-24052) SECURED TO THE HYDROSTATIC RELEASE DEVICE WITH 5 TURNS? (DDG 51 REQ SHACKLES) REF: MIP 5832/009 2 C R NA ******************************************************************************* (I2H0) ARE NEOPRENE RUBBER BANDS INSTALLED AROUND CONTAINER AND NOT DAMAGED? (MK 6) REF: MIP 5832/004 NSTM 583 PARA 12.9.2 3 C R NA ******************************************************************************* 34. STOWAGE, GENERAL (I3AO) ARE THE LIFEBOATS INSTALLED WITH THE SEAPAINTERS FACING AFT? REF: NSTM 583 VOL 1 583-12.9.1 4 C R NA ******************************************************************************* (I3B0) ARE HYDROSTATIC RELEASE DEVICES UNPAINTED AND INSTALLED WITH THE BUTTON FACING INBOARD (TOWARDS TRAFFIC)? IS THE CAN OPENING AFT? REF: NSTM 583 PARA 12.10.2.1 GSO 583F MIP 5832/009 4 C R NA ******************************************************************************* 35. LIFE JACKETS (MK-1) (K4A0) IS PMS AND MATERIAL CONDITION SATISFACTORY (NO TWISTS IN BLADDER, ORAL INFLATION VALVE LOCKED CLOSED, RECALLED CO2) REF: MIP 5832 2 C R NA ******************************************************************************* (K4B0) ARE WHISTLES IN SATISFACTORY MATERIAL CONDITION AND ATTACHED? REF: MIP 5832 5 c R NA ******************************************************************************* (K4C0) ARE LIGHTS IN SATISFACTORY MATERIAL CONDITION AND ATTACHED? REF: MIP 5832 2 c R NA ******************************************************************************* (K4DO) ARE DYE MARKERS INSTALLED CORRECTLY AND IN SATISFACTORY MATERIAL CONDITION? (DYE MARKER POUCH MUST BE PLIABLE) REF: MIP 5832 2 C R NA ******************************************************************************* (K4G0) IS THE INFLATION ASSEMBLY FLAP MARKED: "WARNING AUTOMATIC INFLATION ASSEMBLY INSTALLED. DO NOT USE ABOARD AIRCRAFT"? REF: MIP 5832 2 C R NA ******************************************************************************* 36. ACCOMMODATION LADDER, BROW AND PILOT’S LADDERS (L1A0) HAS THE ACCOMODATION LADDER HAD A COSMETIC COATING APPLIED TO IT (I. E. PAINTED OR POWDER COATED)? IS THERE A DFS TO CONTINUE IT'S USE? REF: COMNAVSURFOR MSG 090304Z APR 07 2 C R NA ******************************************************************************* (L1B0) ARE STANCHIONS AND SOCKETS MATERIAL CONDITION SATISFACTORY? (ARE TOGGLE PINS INSTALLED AND IN PLACE, STAPLES WORN, CRACKED OR MISSING) REF: MIP 6232 3 C R NA ******************************************************************************* (L1C0) ARE ATTACHMENT POINTS, LIFTING BALE AND BRIDLE IN SATISFACTORY MATERIAL CONDITION? ARE ATTACHMENT POINT NUTS/STRAIGHT TYPE SECURING PINS PROVIDED WITH COTTER PINS? ARE SECURING PINS BENT OR WORN, SHACKLE PINS SEIZED, AND/OR COTTER PINS IN PLACE? REF: MIP 6232 SHIPS DWGS 2 C R NA ******************************************************************************* (L1D0) ARE HANDRAILS/CHAINS IN PLACE, MATERIAL CONDITION SATISFACTORY, SHACKLE PINS SEIZED, SECURING PINS/BOLTS IN PLACE? REF: MIP 6232 2 C R NA ******************************************************************************* (L1E0) ARE LADDER UPPER/LOWER PLATFORMS (NUT/STRAIGHT TYPE) AND COTTER PINS IN PLACE, MATERIAL CONDITION SATISFACTORY, SECURING PINS IN TRACTION TREADS IN PLACE, ATTACHMENT POINTS STRUCTURALLY SOUND? REF: MIP 6232, SHIPS DWGS 2 C R NA ******************************************************************************* (L1F0) IS TOE GUARD INSTALLED AT LADDER ROLLER? REF: NAVSEA DWG 804-2255402 MIP 6232 2 C R NA ******************************************************************************* (L1J0) ARE RIGGING SAFETY PLACARDS POSTED EACH STATION? REF: GSO 602H 4 C R NA ******************************************************************************* (L1L0) ARE LADDER WINCH SAFETY, OPERATING AND LUBRICATION CHARTS POSTED? (AS APPLICABLE) REF: GSO 602H 3 C R NA ******************************************************************************* (L1M0) ARE PILOT’S LADDERS STEPS AND SPREADER BARS IS SAFISFACTORY CONDITION? ARE LINE SUSPESION MEMBERS CUT OR CHAFED? REF: MIP 6232 NAVSHIP DWG 804-5000900 2 C R NA ******************************************************************************* (L1N0) IS PILOTS LADDER INSTALLED CORRECTLY? ARE RAILINGS AND SUPPORT STRUCTURE IN SATISFACTORY MATERIAL CONDITION REF: MIP 6232 NAVSHIPS DWG 804-5000900 2 C R NA ******************************************************************************* 37. TOPSIDE LADDERS, INCLINE AND VERTICAL (L2B0) ARE THREADS MATERIAL CONDITIONS SATISFACTORY? IE WORN, BROKEN, MISSING BOLTS OR PAINTED. REF: MIP 6641 3 C R NA ******************************************************************************* (L2C0) ARE HANDRAILS IN PLACE, MATERIAL CONDITION SATISFACTORY? REF: MIP 6641 3 C R NA ******************************************************************************* (L2F0) ARE SECURING BOLTS OR TOGGLE PINS INSTALLED AT THE HEAD AND/OR FOOT? REF: MIP 6641 3 C R NA ******************************************************************************* (L2G0) ARE OPENINGS BETWEEN UPPER HANDRAIL STANCHIONS AND ADJACENT RAILS OR STRUCTURES NO GREATER THAN 5 INCHES? REF: GSO 622C, 612D 3 C R NA ******************************************************************************* (L2I0) ARE SECURING PADS IN PLACE, STRUCTURALLY SOUND? REF: MIP 6641 3 C R NA ******************************************************************************* (L2K0) ARE SAFETY CHAINS INSTALLED AND PROPERLY RIGGED WHERE REQUIRED? REF: MIP 6641 GSO 622B 2 C R NA ******************************************************************************* 38. LIFELINES (L3A0) ARE HEAVY WEATHER LIFELINES AVAILABLE AT LOCATIONS WHERE OTHER MEANS OF SUPPORT (LIFELINES, GRABRAILS, OR EQUIVALENT MEANS) ARE NOT WITHIN REASONABLE REACH OF PERSONNEL? REF: NAVSHIPSDWG 805-263-6908 AND 6909 GSO 612B 2 C R NA ******************************************************************************* (L3C1) ARE LIFELINES AND END FITTINGS ON MINE WARFARE SHIPS SERIES 304CRES? REF: GSO 612B NAVSEA DWGS, 803-5000903, 803-5000938, 804-4354051 3 C R NA ******************************************************************************* (L3F0) ARE HEAVY WEATHER LINES 9/16" DIA PHOSPHOR BRONZE 5/8" DIA 1PS-1WRC (AS APPLICABLE) REF: GSO 612B NAVSEADWG 805-2636908/2636909 3 C R NA ******************************************************************************* (L3H0) IS PMS AND MATERIAL CONDITION OF THE LIFELINE SYSTEM SATISFACTORY? ARE TURNBUCKLES AND LOCK NUTS INSTALLED AND SET? REF: MIP 6121 NAVSEADWG 804 5184155 2 C R NA ******************************************************************************* (L3I0) ARE OPENINGS BETWEEN STANCHIONS, RAILS AND OTHER EQUIPMENT 5" OR LESS? REF: GSO 612B NAVSEADWG 804-5184155 2 C R NA ******************************************************************************* (L3J0) ARE LIFE LINES/RAILS SPACED THREE COURSES HIGH AT A HEIGHT OF 42" FROM THE CENTER OF THE TOP RAIL/LINE TO DECK, EXCEPT 36" SHALL BE PROVIDED WHEREVER HEIGHT OF RAIL IS RESTRICTED? REF: NAVSEADWG 804-5184155 GSO 612D 2 C R NA ******************************************************************************* (L3K0) ARE PORTABLE LIFELINES, SAFETY CHAINS AND STANCHIONS AVAILABLE AROUND FLIGHT DECK/CARGO HATCHES, ELEVATORS AND FLIGHT DECK (DURING NON-AIRCRAFT OPS) REF: GSO 612D NAVSEADWG 804-5184155 2 C R NA ******************************************************************************* (L3L0) ARE THE FLIGHT DECK EDGE AND FILLER NETS WEIGHT TESTED? ANNUAL(NYLON), 36M (CRES). REF: PMS MIP 6122 2 C R NA ******************************************************************************* (L3M0) IS PMS BEING CONDUCTED ON FLIGHT DECK EDGE AND FILLER NETS? REF: PMS MIP 6122 2 C R NA ******************************************************************************* 39. STANCHIONS (L4A0) ARE END STANCHION SUPPORT BRACES IN PLACE? REF: GSO 612 NAVSEA DWG 804-5184155 3 C R NA ******************************************************************************* (L4B0) ARE 9-INCH CHAFING SLEEVES INSTALLED ON LIFELINE WHERE THEY PASS OVER STANCHIONS AND J-HOOKS? (NA KEVLAR INSTALLED) REF: MIP 6121 GSO 612B 3 C R NA ******************************************************************************* (L4C0) ARE CHAFING SLEEVES IN MISSLE BLAST AREAS, MONEL, OR IN GOOD SHAPE (NA KEVLAR) REF: MIP 6121 4 C R NA ******************************************************************************* (L4D0) ARE STANCHION STAPLES AND J-HOOKS 5/8" MINIMUM DIAMETER? ALUMINUM, 1/2" DIAMETER MINIMUM STEEL, AND STRUCTURELY SOUND (1/8" WEAR ALLOWED IN WEAR AREA ONLY) REF: MIP 6121 NAVSHIPDWG 804-5184155 3 C R NA ******************************************************************************* (L4E0) ARE STANCHIONS, TOGGLE PINS INPLACE (WORN THIN, DAMAGED OR MISSING) REF: MIP 6121 2 C R NA ******************************************************************************* (L4F0) ARE STANCHION J-HOOKS ATTACHED FACING INBOARD AND FORWARD? (45 DEGREES) REF: NAVSHIPDWG 804-5184155 GSO 612D 5 C R NA ******************************************************************************* (L4I0) IN MINEWARFARE SHIPS, ARE STANCHIONS CRES? REF: GSO 612B 5 C R NA ******************************************************************************* (L4J0) IN ALUMINUM HULL SHIPS AND ON ALUMINUM ALLOY DECKS ARE STANCHIONS EITHER CRES OR ALUMINUM-ALLOY? REF: GSO 612B 5 C R NA ******************************************************************************* 40. ACCESS, HATCH GUARD, HATCH, OTHER OPENINGS (L5F0) IS THE SAG AT ANY MIDSPAN OF ROPE OR CHAIN NOT MORE THAN 3/4 INCH/FT OF SPAN? REF: GSO 612D 3 C R NA ******************************************************************************* (L5G0) ARE ACCESS OPENING ASSEMBLIES REQUIRING EASY ATTACHMENT/ DETACHMENT FITTED WITH 5/8 INCH DIA POLYESTER ROPE MILSPEC. MIL-G-30500 or 3-STRAND NYLON ROPE PER MIL-R-17343, A 5/16 INCH SCREW PIN SHACKLE AT ONE END, AND A 4 INCH GALVANIZED STEEL SNAPHOOK WITH SAFETY GUARD AT THE OTHER END. THE SNAPHOOK SHALL HAVE A 5/8 DIAMETER EYE, A 3/4 INCH THROAT OPENING, AND SHALL WITHSTAND A PROOF-LOAD OF 5,000 POUNDS. REF: GSO 612D 2 C R NA ******************************************************************************* (L5H0) ARE ACCESS OPENINGS GREATER THAN 72 INCHES PROVIDED WITH INTERMEDIATE PORTABLE STANCHIONS TO SUPPORT THE ROPE/CHAIN? REF: GSO 612D 2 C R NA ******************************************************************************* 41. DECK, GENERAL (M1A0) ARE FAIRLEADS IN SATISFACTORY CONDITION? REF: MIP 6111 4 C R NA ******************************************************************************* (M1B0) ARE CHOCKS IN SATISFACTORY CONDITION (NO GROVES OR SHARP EDGES, ROLLERS FREE AS APPLICABLE)? REF: MIP 5821, 6111 NSTM 613 PARA 2.8.2.4 4 C R NA ******************************************************************************* (M1C0) ARE BITTS IN SATISFACTORY CONDITION, PADEYES INSTALLED FORE/AFT FOR ATTACHING STOPPERS (NO GROVES OR SHARP EDGES)? REF: MIP 5821, 6111 NSTM 613 PARA 2.8.2.4 NAVSHIPDWG 804-1843362 REV A 4 C R NA ******************************************************************************* (M1D0) ARE CLEATS IN SATISFACTORY CONDITION? REF: MIP 5821 NSTM 613 PARA 2.8.2.4 4 C R NA ******************************************************************************* (M1E0) ARE DECK PADEYES IN SATISFACTORY CONDITION, AND TEST LABEL PLATES INSTALLED? REF: MIP 5821 GSO 602G, 611D 4 C R NA ******************************************************************************* 41. SAR J-BAR DAVITS (1 PORT AND 1 STARBOARD) (O2D0) ARE DAVIT SNATCH BLOCKS SEIZED? ARE THE SHACKLES THE RIGHT SIZE AND TYPE? (MIN ½” ANCHOR SAFETY SHACKLE), 8” SNATCH BLOCK. REF: NTTP 3-50.1A FIG A 3 C R NA ******************************************************************************* 42. RESCUE KIT, SWIMMER (QUANTITY FOR EACH) (O4A0) IS WET SUIT (GLOVES, HOOD, BOOTS) PROVIDED? REF: NTTP 3.50.1A 5.2.1 MIP 5832 NAVAIR 13-1-6.5 2 C R NA ******************************************************************************* (O4B0) IS A FACE MASK WITH CHEMLITE ATTACHMENT PROVIDED? REF: NTTP 3.50.1A 5.2.3 MIP 5832 NAVAIR 13-1-6.5 2 C R NA ******************************************************************************* (O4C0) ARE SWIM FINS PROVIDED? REF: NTTP 3.50.1A 5.2.5 MIP 5832 NAVAIR 13-1-6.5 2 C R NA ******************************************************************************* (O4D0) IS A HARNESS PROVIDED (C.G. N/A)? REF: NTTP 3.50.1A 5.2.8 MIP 5832 NAVAIR 13-1-6.5 2 C R NA ******************************************************************************* (O4E0) IS A "J" KNIFE PROVIDED? REF: NTTP 3.50.1A 5.2.1.1 MIP 5832 NAVAIR 13-1-6.5 2 C R NA ******************************************************************************* (O4F0) ARE TWO 4" AND TWO 6" CHEMICAL LIGHTS PROVIDED? REF: NTTP 3.50.1A 5.2.1.1 MIP 5832 NAVAIR 13-1-6.5 2 C R NA ******************************************************************************* (O4G0) IS A LP 28 TYPE OR SAR-1 (C.G. ONLY) LIFE VEST WITH WHISTLE AND BLUE STROBE LIGHT PROVIDED? REF: NTTP 3.50.1A 5.2.6 MIP 5832/022 NAVAIR 13-1-6.5 2 C R NA ******************************************************************************* 43. (O4H0) ARE THERE 2 SWIMMER TENDING LINES, 300 YDS LONG OF 3/4-INCH CIRCUMFERENCE, 800-POUND TEST POLPROPYLENE LINE WITH A 2-3/8 INCH STAINLESS STEEL SNAP HOOK ON ONE END. ARE THE LINES REELED ON COMPACT SPOOLS. REF: NTTP 3-50.1A 5.12 ANNEX A 2 C R NA