ELECTRICAL 04/15/2008 THE FOLLOWING STATUS CODES MAY BE CIRCLED ON THE FAR RIGHT C- COMPLETE ON IN EFFECT R- REQUIRES FUTHER ACTION NA- NOT APPLICABLE SAFETY REVIEW ITEMS F. ELECTRICAL 1. ELECTRICAL SAFETY ADMIN (3EEA1D0) (A1C0) DOES THE COMMANDING OFFICER AUTHORIZE ANY DISASSEMBLY OR MAINTENANCE ON ENERGIZED EQUIPMENT? REF: OPNAVINST 5100.19E (B0702A, B0705A) NSTM 300-2.5.1 2 EDORM SECT 3303 A.4.A C R NA ******************************************************************************** (A1DO) IS SHIP COMPLYING WITH ALL SAFETY PROCEDURES REQUIRED FOR WORKING ON ENERGIZED EQUIPMENT? REF: NSTM 300-2.5.2 2 EDORM SECT 3303 A.4.A C R NA ******************************************************************************** (A1E0) DOES THE ELECTRICAL SAFETY OFFICER ENSURE ELECTRICAL/ELECTRONIC INDOCTRINATION TRAINING IS PROVIDED UPON REPORTING AND ANNUALLY THEREAFTER FOR ALL PERSONNEL? REF: OPNAVINST 5100.19E (B0702B, B0708A) OPNAVINST 3120.32C (SORM) SECT 305.9B(1),(2) 2 C R NA ******************************************************************************** (A1F0) HAVE TOOL ISSUE PERSONNEL COMPLETED PQS ELECTRICAL TOOL ISSUE ROOM WATCHSTATION 302 IN THE SAFETY PROGRAMS AFLOAT PQS (NAVEDTRA 43460-4A)? REF: OPNAVINST 5100.19E (B0708C) 2 C R NA ******************************************************************************** (A1G0) DOES THE SHIP HAVE A CERTIFIED AMERICAN RED CROSS/AMERICAN HEART ASSOCIATION CPR INSTRUCTOR ONBOARD? 2 REF: OPNAVINST 5100.19E (B0708B) C R NA ******************************************************************************** (A1G1) IS AT LEAST 50 PERCENT OF ALL ELECTRICAL/ELECTRONICS ASSOCIATED RATINGS CERTIFIED IN BASIC LIFE SUPPORT AT A MINIMUM OF EVERY TWO YEARS? 2 REF: OPNAVINST 5100.19E (B0708B) C R NA ******************************************************************************** (A1HO) HAS THE ELECTRICAL SAFETY OFFICER COMPLETED WATCHSTATION 304 OF THE SAFETY PROGRAMS AFLOAT PQS (NAVEDTRA 43460-4A) WITHIN 16 WEEKS OF ASSIGNMENT? 4 REF: OPNAVINST 5100.19E (B0708D) C R NA ******************************************************************************** (A1IO) DOES THE SHIP HAVE A CENTRALIZED PORTABLE TOOL ISSUE ROOM, AND ARE UNSAFE ELECTRIC TOOLS MARKED “OOC” AND KEPT IN LOCKED STORAGE SEPARATE FROM OTHER TOOLS? 3 REF: OPNAVINST 5100.19E (B0707A, F) C R NA ******************************************************************************** 2. HAZARDOUS MATERIALS (A2A0) ARE ALL HAZARDOUS MATERIALS CONTAINERS AND STORAGE LOCATIONS IN THE WORK CENTER PROPERLY MARKED OR LABELED? 4 REF: OPNAVINST 5100.19E (B0302A12f) C R NA ******************************************************************************** (A2B0) ARE SHOP PERSONNEL FAMILIAR WITH THE HAZARDS, PRECAUTIONS AND PROTECTIVE EQUIPMENT REQUIRED FOR HAZARDOUS MATERIALS HANDLED IN THE WORKCENTER AND THE ASSOCIATED MSDS? 4 REF: OPNAVINST 5100.19E (B0302A12a&b) C R NA ******************************************************************************** 3. HEARING CONSERVATION (A3A0) ARE NOISE HAZARD AREAS AND EQUIPMENT PROPERLY LABELED OR POSTED? REF: OPNAVINST 5100.19E (B0404C1) 3 C R NA ******************************************************************************** (A3B0) IS HEARING PROTECTION AVAILABLE, USED, AND ISSUED AS NECESSARY WITH ELECTRICAL PORTABLE TOOLS? REF: OPNAVINST 5100.19E (B0707C, C0903A5) 3 NSTM 300-2.7.1 C R NA ******************************************************************************** 4. SIGHT CONSERVATION PROGRAM (A4A0) IS PROPER EYE WASH STATION AVAILABLE IN AN UNOBSTRUCTED LOCATION IN BATTERY SHOP/LOCKER THAT REQUIRES NO MORE THAN 10 SECONDS OR 100 FEET OF TRAVEL TO REACH FROM HAZARD? REF: OPNAVINST 5100.19E (B0508A4) GSO 644D 3 NSTM 313-2.5.5.6 C R NA ******************************************************************************** (A4A1) IS EYE PROTECTION PROVIDED WITH PORTABLE TOOLS WHEN PARTICLES MAY FLY IN EYES? REF: NSTM 300-2.7.1 3 OPNAVINST 5100.19E (B0707C, C0903A4) C R NA ******************************************************************************** 5. OPERATING/SAFETY INSTRUCTIONS (A5A0) ARE EQUIPMENT OPERATING INSTRUCTIONS AND SAFETY PRECAUTIONS POSTED FOR EQUIPMENT IN ELECTRICAL SPACES? 3 REF: OPNAVINST 5100.19E (C1304F) C R NA ******************************************************************************** 6. TAG-OUT PROGRAM (A7A0) DOES SHIP HAVE THE MOST CURRENT REVISION OF THE TAG-OUT USER’S MANUAL (REVISION 3) ? REF: NAVSEA TECHNICAL PUBLICATION S0400-AD-URM-010/TUM Rev 3 3 OPNAVINST 3120.32C CH-4 , 630.17A C R NA ******************************************************************************** (A7A1) DO ALL NEWLY REPORTED PERSONNEL RECEIVE TRAINING ON THE TAG-OUT PROGRAM? ARE TAG-OUT “TAG-OUT USER MANUAL” TRAINING TOPICS INCLUDED IN THE COMMANDS CONTINUED TRAINING PROGRAM? REF: TAG-OUT USER’S MANUAL (TUM) Rev 3 SECT. 1.4 2 OPNAVINST 3120.32C CH-4, 630.17F C R NA ******************************************************************************** (A7A2) IS TAG-OUT LOG IN ACCORDANCE WITH TUM AND ARE PROCEDURES CORRECTLY FOLLOWED? REF: TAG-OUT USER’S MANUAL (TUM) Rev 3 1 OPNAVINST 3120.32C CH-4, 630.17 C R NA ******************************************************************************** (A7A3) IF MAINTENANCE OR REPAIR OF EQUIPMENT IS IN PROGRESS, IS EQUIPMENT PROPERLY TAGGED OUT? REF: TAG-OUT USER’S MANUAL (TUM) Rev 3 SECT. 1.5 and 1.6 1 OPNAVINST 5100.19E (C1302A9) C R NA ******************************************************************************** (A7A4) DOES THE SHIP MAINTAIN AN EMERGENCY DIVE BILL TO INCLUDE PRE-PREPARED TAG OUT RECORD SHEETS AND DANGER TAGS? 2 COMNAVSURFORINST 3300.1A C R NA ******************************************************************************** 7. CABLES AND CABLEWAYS (A8A0) ARE DEAD-END CABLES PROPERLY IDENTIFIED AND ISOLATED? REF: NSTM 300-4.6.9 COMFLTFORCOM 4790.3 VOLUME 6 CHAPTER 28 2 DOD-STD-2003 SECT 3 AND 4 C R NA ******************************************************************************** (A8B0) ARE CABLES PROPERLY SUPPORTED WITH CABLE HANGERS/BANDING STRAP, STUFFING TUBES USED ON CABLE PENETRATIONS? REF: DOD-STD-2003 SECT 3 AND 4 COMFLTFORCOM 4790.3 VOLUME 6, CHAPTER 28 GSO 304E 3 NSTM 300-4.6.10.1/.2 C R NA ******************************************************************************** (A8C0) DO SHOCK-MOUNTED MOTORS AND OTHER PIECES OF SHOCK-MOUNTED ELECTRICAL EQUIPMENT HAVE REQUIRED GROUNDING STRAPS? REF: GSO 235J MIL-STD-1310 NAVSEA DRAWING 803-5001027 3 PMS MIP 3000/001 24M-1 C R NA ******************************************************************************** 8. TEST EQUIPMENT (A9A0) ARE SHORTING PROBES MODIFIED AND MAINTAINED IAW PMS MIP 3000? 3 REF: PMS MIP 3000/001, PMS MIP 3000/100 C R NA ******************************************************************************** 9. HEATERS (AAA0) ARE APPROVED QUARTERDECK PORTABLE ELECTRICAL HEATERS BEING USED? 4 REF: NAVSURWARCEN LETTER 9213/176 11 SEP 03. C R NA ******************************************************************************** 10. SWITCHBOARD SAFETY (B1A0) ARE OPERATING INSTRUCTIONS AND SAFETY PRECAUTIONS POSTED IN THE VICINITY OF THE SWITCHBOARD? NSN: DANGER HIGH VOLTAGE SIGNS- 0118-LF 113-2400 0118-LF-113-2300 4 Step CPR Placard 0118-LF-019-6500 SAFETY PRECAUTIONS ELECTRICAL- 0118-LF-019-6100 WARNING FOR RESCUING SHOCK VICTIMS-0118-LF-020-2700 5 REF: GSO 602H, 070H C R NA ******************************************************************************** (B1B0) HAVE REQUIRED 100 AMP CIRCUIT BREAKER FUSE UNITS BEEN MODIFIED WITH REQUIRED PLASTIC COVERS? REF: NAVSURFWARCEN SHIPSYSENGSTA, PHILADELPHIA,PA MESSAGE 2 211800ZNOV02. C R NA ******************************************************************************** (B1C0) ARE DANGER SHOCK HAZARD AND DANGER HIGH VOLTAGE SIGNS POSTED WERE APPLICABLE? 3 REF: GSO 070 H, 602H C R NA ******************************************************************************** (B1D0) ARE PANEL ENCLOSURES IN GOOD MATERIAL CONDITION? REF: NSTM 300-4.8.1, 4.8.2 4 MIP 3240/002 C R NA ******************************************************************************** (B1E0) ARE METERS OPERATIVE AND CALIBRATED? REF: NSTM 300-3.2.3, 3.2.4, 4.8.1H NSTM 491-3.4.4/.5/.6 4 COMFLTFORCOM 4790.3 VOLUME VI, CHAPTER 9 C R NA ******************************************************************************** (B1F0) ARE CIRCUITS FREE OF GROUNDS? REF: NSTM 300-3.2.5/.6/.7 3 NSTM 320-1.6.9.3, 320-1.2.1.1 C R NA ******************************************************************************** (B1G0) ARE WOODEN GRAB RAILS PROPERLY INSTALLED? REF: NSTM 320-2.2.6.2 5 GSO 622 E C R NA ******************************************************************************** (B1I0) IS THE SWITCHGEAR FREE OF ANY OPENINGS WHERE BREAKERS OR OTHER DEVICES HAVE BEEN REMOVED? 4 REF: GSO 324 C C R NA ******************************************************************************** (B1J0) IS LIGHTING, EMERGENCY LIGHTING, AND HAND LANTERNS IN THE VICINITY OF THE SWITCHGEAR ADEQUATE? REF: GSO 332E, GSO 332G 4 NSTM 330-1.6.4.3.3.1 C R NA ******************************************************************************** (B1K0) ARE VENTILATION DUCTS DIRECTED AWAY FROM THE SWITCHGEAR? REF: NSTM 320-2.2.6.4 (L) 4 NSTM 300-4.8.1.1 C R NA ******************************************************************************** (B1L0) IS RUBBER MATTING OF THE PROPER MATERIAL AND CORRECTLY INSTALLED AROUND SWITCHBOARDS IAW REFERENCES? REF: NSTM 634-3.12.2 GSO 634C NSTM 320-2.2.6.2 NSTM 300-4.8.1.1 4 NSTM 300-4.4.2.2.1 C R NA ******************************************************************************** 11. SHORE POWER (C1A0) DO SHORE POWER CABLES APPEAR TO BE SAFE AND WELL PROTECTED? REF: NSTM 320-2.2.7.2 (5)(6) 2 PMS MIP 3201/006, MIP 3211/001 C R NA ******************************************************************************** (C2A0) ARE THE SHORE POWER RECEPTACLES PROVIDED WITH A RECEPTACLE CONTROL SWITCH TO OPEN ASSOCIATED BREAKER WHENEVER THE RECEPTACLE COVER IS OPENED, OR THE PLUG REMOVED, AND IS EACH RECEPTACLE PROVIDED WITH A PILOT LIGHT? REF: NSTM 320-2.2.7.2 PMS MIP 3201/006, MIP 3211/001 2 GSO 320 D C R NA ******************************************************************************** (C3A0) IS SHORE POWER BEING RIGGED AND UNRIGGED CORRECTLY INCLUDING CORRECT TAG-OUTS? REF: (EOSS) PROCEDURE SPRU NSTM 320-2.2.7.2 1 TAG-OUT USER’S MANUAL (TUM) Rev 3 C R NA ******************************************************************************** 12. CASUALTY POWER (D1A0) ARE CASUALTY POWER CABLES AND TERMINALS IN SATISFACTORY CONDITION? REF: NSTM 320-1.2.8, 320-3.4 NSTM 079(V3) 079-47.4.2 NSTM 079(V3) FIGURE 079-47.2 3 PMS MIP 3201/002, MIP 3212/002, MIP 3201/006 C R NA ******************************************************************************** (D1A1) ARE CASUALTY POWER TERMINALS PROPERLY LABLED, WITH WARNING SIGNS POSTED ON NORMALLY HOT TERMINALS? REF: NSTM 320-1.2.8.2, 320-3.4 NSTM 079(V3) 079-47.4.2.3.5 GSO 320G 3 PMS MIP 3201/002, MIP 3212/002, MIP 3201/006 C R NA ******************************************************************************** (D2A1) ARE RISER AND BULKHEAD TERMINALS COVERED WHEN NOT IN USE? REF: NSTM 079 (V3) 47.4.2.3.4 and .6 GSO 320G 4 PMS MIP 3201/002, MIP 3212/002, MIP 3201/006 C R NA ******************************************************************************** 13. CONTROLLERS, ABTS, FUSE AND POWER PANELS (E1A0) ARE MEGGER TEST HOLES PLUGGED ON POWER PANELS, SWITCHBOARDS, AND THE POWER SUPPLY CIRCUIT BREAKERS OF MANUAL BUS TRANSFERS? REF: GENADMIN NAVSEA 230319ZNOV98 4 NSN 5340-01-081-1718 C R NA ******************************************************************************** (E1B0) DO CONTROLLERS WITH ELECTRICAL COMPONENTS RATED AT 30 VOLTS AC/DC OR GREATER MOUNTED ON THE CONTROLLER DOOR HAVE GROUNDING STRAP CONNECTED BETWEEN THE DOOR AND THE MAIN BODY OF THE CONTROLLER? 3 REF: PMS 3001/002 C R NA ******************************************************************************** 14. CONTROLLERS, ABT'S, MBT’S, FUSE PANELS, AND POWER PANELS (F1A0) ARE CONTROLLERS CLEAN, DRY, AND CLEAR OF LOOSE GEAR? REF: APPLICABLE PMS NSTM 300-4.8.1 4 NSTM 320-3.2.1 C R NA ******************************************************************************** (F1D0) ARE INDICATOR LIGHTS OPERATIVE AND OF CORRECT COLOR? 4 REF: NSTM 320-2.2.9, AND GSO 305 G C R NA ******************************************************************************** (F1G0) ARE FUSE BOXES PROPERLY LABELED (INCLUDING THE CIRCUIT CONTROLLED, THE PHASES OR POLARITIES, AND THE FUSE AMPERE RATINGS)? REF: GSO 305 E 5 MIP 3301/005, 3240/002, 3311/002 C R NA ******************************************************************************** (F1H0) IS THERE EVIDENCE OF IMPROPERLY RIGGED, NICKEL-PLATED FUSES, UNDERFUSING, COTS FUSES, OR OVERFUSED ELECTRICAL CIRCUITS? REF: GSO 303H 4 MIP 3301/005, 3240/002, 3311/002 C R NA ******************************************************************************** (F1I0) DO DISTRIBUTION PANELS HAVE CIRCUIT INFORMATION PLATES ADJACENT TO THE HANDLE OF EACH CIRCUIT BREAKER, WITH INFORMATION IN THE FOLLOWING ORDER: CIRCUIT NUMBER, NAME AND LOCATION OF EQUIPMENT? REF: GSO 305 E MIP 3301/005, 3240/002, 3311/002 NSTM 300-1.7.4 5 NSTM 300-2.5.4.1 C R NA ******************************************************************************** (F1J0) ARE DOORS INSTALLED ON CABINETS FOR DISTRIBUTION PANELS IN UNMANED SPACES? 5 REF: GSO 324 C C R NA ******************************************************************************** (F1L0) ARE ELECTRICAL PANEL, CONTROLLER, AND JUNCTION BOX COVERS CLOSED? REF: NSTM 300-2.3.1.3, 300-2.3.2E NSTM 302-3.3.2I 4 OPNAVINST 5100.19E (C0903 H) C R NA ******************************************************************************** (F1M0) ARE CLEARANCES PROVIDED IN THE IMMEDIATE VICINITY OF ELECTRICAL EQUIPMENT AND MACHINERY TO PERMIT COMPLETE ACCESSIBILITY FOR OPERATION, MAINTENANCE, REPAIRS, RENEWAL OF FUSES, AND TESTING? 4 REF: GSO 300D, 070H C R NA ******************************************************************************** (F1N0) ARE SHIELDS INSTALLED AS NECESSARY TO PROTECT ELECTRIC EQUIPMENT AND MACHINERY FROM JETS OR SPRAY RESULTING FROM THE NORMAL OPERATION OF, OR DAMAGE TO, PUMPS, PIPES, TUBES, COUPLINGS, VALVES OR FITTINGS IN WATER, STEAM OR OIL PIPING SYSTEMS? 4 REF: GSO 300D C R NA ******************************************************************************** 15. BATTERIES (G1A0) DOES BATTERY LOCKER HAVE ADEQUATE PERSONNEL SAFETY EQUIPMENT (INCLUDING PROPER STORAGE AND VENTILATION)? REF: NSTM 313-2.4.4.1, 2.4.8, GSO 313F 3 OPNAVINST 5100.19E (C0904N3) C R NA ******************************************************************************** (G1B0) *ARE BATTERIES PROPERLY SECURED IN THEIR RACKS? REF: DOD-STD-2003 5 GSO 313F C R NA ******************************************************************************** (G1C0) ARE OPERATING INSTRUCTIONS AND SAFETY PRECAUTIONS POSTED? SAFETY PRECAUTIONS ELECTRICAL- 0118-LF-019-6100 SAFETY PREECAUTIONS STORAGE BATTERIES- 0118-LF-114-3900 NO SMOKING BATTERY ON CHARGE 0118-LF-113-3600 REF: GSO 602H NSTM 090 NSTM 313-2.10 5 OPNAVINST 5100.19E (C0904) C R NA ******************************************************************************** (G1D0) IS THE BATTERY SHOP EXHAUST VENTILATION INTERLOCKED WITH THE POWER SUPPLY TO BATTERY CHARGER? REF: GSO 313F PMS MIP 3131/005 NSTM 510-6.1.11 4 OPNAVINST 5100.19E (C0904A) C R NA ******************************************************************************** (G1G0) ARE DELUGE SHOWER, EYE-FACE BATH AND DRAIN INSTALLED IN BATTERY LOCKER AND BATTERY SHOP? REF: GSO 644D NSTM 313-2.5.5.6 5 OPNAVINST 5100.19E (B0508D) C R NA ******************************************************************************** (G1H0) ARE THERE 2 BATTERY WATER CONTAINERS AND ONE SODA WATER CONTAINER PROVIDED IN BATTERY ROOM AND CHARGING SHOP? CONTAINERS SHALL BE 5-GAL POLYETHYLENE BOTTLES NSN 8125-00-888-7069. REF: GSO 313F 5 NSTM 313-2.5.5.6 C R NA ******************************************************************************** (G1I0) ARE (PPE) RUBBER APRON, RUBBER BOOTS, CHEMICAL RUBBER GLOVES AND FULL FACE SHIELD PRESENT AND IN GOOD CONDITION? REF: OPNAVINST 5100.19E (C0904N3) 4 NSTM 313-2.5.5.4 C R NA ******************************************************************************** (G1J0) IS THERE A 15-LB CO2 FIRE EXTINGUISHER LOCATED WITHIN 30 FT OF THE CHARGING STATION? 4 REF: GSO 555 B1 C R NA ******************************************************************************** (G1K0) ARE ACID STOWAGE LOCKERS LARGE ENOUGH TO STORE THE TOTAL QUANTITY OF ACIDS, WITH TIGHT FITTING LIDS OR DOORS AND LINED WITH LEAD OR ACID RESISTANT SYNTHETIC RUBBER, TYPE II, WITH ADEQUATE SIZE SPILL TRAY? REF: PMS MIP 6600/002 5 GSO 671 C C R NA ******************************************************************************** 16. LIGHTING (H1B0) DO WEATHERDECK LIGHTING FIXTURES APPEAR TO BE WATERTIGHT AND FREE FROM WATER INTRUSION? REF: NSTM 300.4.4.5 NSTM CHAP 300 TABLE 300-4-4 (CABLEWAY INSPECTION CRITERIA) 4 C R NA ******************************************************************************** (H1C0) IS CORRECT LIGHTING BEING USED FOR BROW ILLUMINATION? REF: NSTM 330.1.9.2.4, GSO 332G NAVSAFECEN ADVISORY 03-95 NSN: 6210-00-283-9691 (LIGHTING FIXTURE) 2 6210-00-399-7120 (HANGAR) C R NA ******************************************************************************** (H1D0) ARE MED./DRESS SHIP LIGHTS OF THE PROPER TYPE? IN GOOD CONDITION? REF: DOD-HDBK-289 (SH) APPENDIX B SECTION A SHEETS 1&6 5 NSTM 330-1.9.2.16/18 C R NA ******************************************************************************** (H1E0) ARE FLOURESCENT AND INCANDESCENT LIGHT FIXTURES PROPERLY SHIELDED? REF: DOD-HDBK-289 SECT 6.6 NSTM 330-2.5, 330-2.2.13 5 GSO 332B C R NA ******************************************************************************** (H1G0) ARE RELAY OPERATED HAND LANTERNS PROPERLY INSTALLED WHERE REQUIRED, I.E., ESCAPE ROUTES, VITAL EQUIPMENT, FLUSH DECK SCUTTLES, BRIDGE AREA, LAUNDRY, PANTRY, GALLEY, INSIDE AND OVER DOOR OF WALK-IN REEFER, WORKSHOPS, AND OVER SAFES CONTAINING CLASSIFIED MATERIAL? 4 REF: NSTM 330-1.6.4.3.3.1, AND GSO 332G C R NA ******************************************************************************* (H1H0) ARE ALL RELAY OPERATED BATTLE LANTERNS MOUNTED UPRIGHT? REF: NSTM 330-1.6.4.3.3.3 LIGHTING ON NAVAL SHIPS APPENDIX B, 4 SECTION A, SHEET 6 C R NA ******************************************************************************** 17. WORKBENCHES (I1A0) ARE ALL ELECTRICAL WORKBENCHES INSULATED AND GROUNDED? REF: PMS MIP 6652/006 NSTM 300 APPENDIX H 5 GSO 665F, 400C, 07OH C R NA ******************************************************************************** (I1D0) IS THE TOP WORKING SURFACE OF THE BENCH INSULATED WITH 3/8" BENELEX 401? NSN 5970-01-030-2607 REF: PMS MIP 6652/006 NSTM 300 APPENDIX H 4 GSO 665F C R NA ******************************************************************************** (I1E0) ALL OTHER VERTICAL SURFACES COVERED WITH 1/8" PLASTIC LAMINATE? NSN 5970-00-912-1908 REF: PMS MIP 6652/006 NSTM 300 APPENDIX H 4 GSO 665F C R NA ******************************************************************************** (I1F0) ARE ALL HINGES AND DRAWER HANDLES MADE OF NYLON? REF: PMS MIP 6652/006 NSTM 300 APPENDIX H 4 GSO 665F C R NA ******************************************************************************** (I1G0) IS THERE A DISCONNECT SWITCH MOUNTED 48 TO 54 INCHES ABOVE THE DECK AND WITHIN A RED-PAINTED TARGET OFFSET FROM THE ELECTRICAL WORKBENCH (NOT OVER THE BENCH) TO SECURE THE POWER TO THE 115 VOLT RECEPTACLES LOCATED ON, OVER, OR NEAR THE BENCH? REF: PMS MIP 6652/006 NSTM 300 APPENDIX H NAVSEA ADVISORY NO. 019-04 5 GSO 320C C R NA ******************************************************************************** (I1H0) IS THERE A WARNING SIGN POSTED ABOVE THE ELECTRICAL WORKBENCH "WARNING ELECTRICAL SHOCK DO NOT TOUCH ENERGIZED CIRCUITS?" REF: PMS MIP 6652/006 NSTM 300 APPENDIX H NAVSEA ADVISORY NO. 019-04 5 GSO 665F C R NA ******************************************************************************** (I1I0) ARE ALL SAFETY PRECAUTION SIGNS INCLUDING: ARTIFICIAL RESPIRATION INSTRUCTIONS AND INSTRUCTIONS WHICH GIVE AN APPROVED METHOD OF RESCUING PERSONNEL IN CONTACT WITH ENERGIZED CIRCUITS POSTED IN THE VICINITY OF THE BENCH? REF: PMS MIP 6652/006 NAVSEA ADVISORY NO. 019-04 5 GSO 665F C R NA ******************************************************************************** 18. ELECTRICAL TOOLS (J1A0) IS THERE A ONE-TIME/INITIAL INSPECTION BEING CONDUCTED AND EQUIPMENT TAGGED ON ALL PERSONAL ELECTRICAL EQUIPMENT PRIOR TO INTRODUCTION ONBOARD? NOTE: THE FOLLOWING PERSONAL ITEMS ARE PROHIBITED FROM SHIPBOARD USE: FANS, PORTABLE EXTENSION CORDS, HIGH-INTENSITY LAMPS, READING LAMPS, ELECTRIC BLANKETS, HEATING PADS, TOOLS EXCEPT HOBBY TOOLS, HEAT/SUN LAMPS, HOT PLATES, AND GRIDDLES, ELECTRIC CLOCKS, MICROWAVE OVENS, PORTABLE EXTENSION LIGHTS, ELECTRIC HEATERS, PORTABLE REFRIGERATORS AND AIR CONDITIONERS, AND IMMERSION-TYPE WATER HEATERS. REF: NSTM 300.2.7.5.2.1D, 300.2.7.3.6.4, 300.2.7.3.4, 4 300.2.7.3.6.2, 300.2.7.3.6.9, 300-2.7.3.6.1 C R NA ******************************************************************************** (J1B0) ARE EXPLOSIVE-PROOF TYPE PORTABLE EXTENSION LIGHTS BEING USED VICE OPEN TYPE? 2 REF: NSTM 330-1.9.2.23, 330-1.9.2.24 C R NA ******************************************************************************** (J1C0) IS PORTABLE AND MOBILE ELECTRIC EQUIPMENT BEING SAFETY CHECKED IAW CURRENT DIRECTIVE INCLUDING BERTHING FLATIRONS? REF: PMS MIP 3000/001 GSO 640G 4 OPNAVINST 5100.19E (B0702E2, B0702E3) C R NA ******************************************************************************** (J1D0) ARE ALL SURGE PROTECTORS AUTHORIZED FOR USE ONBOARD SHIP AND CHECKED IAW PMS? REF: OPNAVINST 5100.19E (C0903S) NSTM 300-2.7.3.5.E 2 PMS MIP 3000/001 C R NA ******************************************************************************** (J1EO) ARE ALL PERSONAL PROTECTIVE EQUIPMENT IN THE TOOL ISSUE PROPERLY MAINTAINED INCLUDING: RUBBER GLOVES PROPERLY PMS’ED AND PLACED IN ORIGINAL BOX/PROTECTED FROM DAMAGE DURING STORAGE. LEATHER OVER-GLOVES AVAILABLE TO PROTECT RUBBER GLOVES FROM DAMAGE DURING USE. IS EYE PROTECTION AVAILABLE FOR ISSUE. REF: PMS MIP 3000/001, NSTM 300-2.5.3.4 4 OPNAVINST 5100.19E (B0706B, B1203C8, C0903A4) C R NA ******************************************************************************** (J1FO) IS THERE AN ELECTRICAL REPAIR KIT IN THE REPAIR LOCKER (S) OR DAMAGE CONTROL UNIT (DCUL), DAMAGE CONTROL UNIT PATROL STATION (DCUPS), AND RESCUE AND ASSISTANCE RE-ENTRY LOCKER (REL)? REF: AEL 2-880044243 3 AEL 2-880044244 C R NA ******************************************************************************** 19. GALLEY (K1B0) IS THE CIRCUIT BREAKER SUPPLYING POWER TO EACH DEEP FAT FRYER PROVIDED WITH A SHUNT TRIP COIL? 2 REF: GSO 320E C R NA ******************************************************************************** (K1C0) IS OFF/ON TOGGLE SWITCH GUARD FOR MEAT SLICING MACHINE SET UP TO PREVENT INADVERTENTLY STARTING? 5 REF: OPNAVINST 5100.19E (C1905A5, C1905F5) C R NA ******************************************************************************** (K1D0) IS "DANGER SHOCK HAZARD" SIGN POSTED ON ALL GALLEY ELECTRICAL EQUIPMENT (WHERE VOLTAGES ARE BETWEEN 30 VOLTS AND 500 VOLTS)? 2 REF: GSO 070H C R NA ******************************************************************************** (K1E0) ARE ELECTRICAL EQUIPMENT OPERATING INSTRUCTION AND SAFETY PRECAUTIONS PROPERLY POSTED AND PERSONNEL FAMILIAR WITH THEIR CONTENTS? REF: GSO 602H 3 OPNAVISNT 5100.19E (C1902D) C R NA ******************************************************************************** (K1F0) IS GARBAGE GRINDER IN SAFE OPERATING CONDITION WITH SAFETY CLEANOUT INTERLOCK AND INDICATING LIGHTS FUNCTIONING PROPERLY? REF: MANUFACTURER’S TECH MANUAL, PMS MIP 6517, AND 2 OPNAVINST 5100.19E (C1904C, C1902O) C R NA ******************************************************************************** (K1J0) ARE THE GREASE INTERCEPTOR HOOD EXHAUST DAMPER THERMOSTATIC SWITCHES TESTED IAW PMS? 4 REF: PMS MIP 5121/004 C R NA ********************************************************************************