Protecting People and the EnvironmentUNITED STATES NUCLEAR REGULATORY COMMISSION
SSINS No.: 6835
IN 84-55, Supplement 1
UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF INSPECTION AND ENFORCEMENT
WASHINGTON, D.C. 20555
May 14, 1985
Information Notice No. 84-55, SUPPLEMENT 1: SEAL TABLE LEAKS AT PWRs
Addressees:
All nuclear power reactor facilities holding an operating license (OL) or a
construction permit (CP).
Purpose:
This supplement to Information Notice (IN) 84-55 provides additional
information concerning seal table leaks and failures of compression type
mechanical fittings. A correction also has been included in this supplement
concerning the use of the term "SWAGELOK" fitting. It is expected that
recipients will review the information for applicability to their facilities
and consider actions, if appropriate, to preclude a similar problem
occurring at their facilities. However, suggestions contained in this
supplement do not constitute requirements; therefore, no specific action or
written response is required.
Background:
IN 84-55 described two events that led to primary reactor coolant leaks at
the seal table. The leaks were caused by failure of the mechanical seals
during maintenance under high-pressure conditions. These events occurred at
Sequoyah 1 and Zion 1. INPO Significant Event Report (SER) 43-84 and
Supplement 1 to SER 43-84 also discuss these two events as well as the
Trojan event (LER 84-014) that occurred on September 13, 1984.
Further review of the Sequoyah event by the Tennessee Valley Authority (TVA)
determined the exact cause of the high-pressure seal failure. Their review
showed that the design of the as-supplied cleaning tool had been modified by
Sequoyah personnel and that these modifications produced a tool that would
transfer force to the thimble tube high-pressure seal at a level sufficient
to cause separation of the seal assembly. The original cleaning tool,
supplied by Teleflex, Inc., consisted of a drivebox and flexible plastic
tube that connected to the upper flare fitting at the end of the thimble
tube. Use of the handcrank on the drivebox moved the cleaning tool into or
out of the thimble tube. Excessive force could not be transmitted to the
fitting of the high-pressure seal because the flexible plastic tube would be
the weakest component subjected to stress. However, because of the
flexibility of the plastic tube, the workers had difficulty feeding the
cleaning device through the drivebox into the tube. During 1978 or 1979,
plant personnel, to compensate for this difficulty, had modified the tool by
a metal extension sleeve that threaded onto the thimble tube flare fitting.
This modified tool was remodified on several occasions because of missing
pieces or further attempts to improve tool stability.
.
IN 85-55, Supplement 1
May 14, 1985
Page 2 of 4
The tool that was used during the Cycle 3 refueling consisted of a base that
slipped over the thimble tube assembly at the seal table and a metal
extension piece that threaded on to the thimble tube flare fitting to which
the drivebox was attached. This tool was lost during containment cleanup
activities before plant startup. When the decision was made to clean the
tubes at power, another tool was fabricated with a slightly shorter base,
which did not mate flush with the upper extension piece. Shims were used to
try to correct this problem, but they appear to have still allowed some
fulcrum effect causing the seal to fail.
In addition to the events discussed in IE IN 84-55, several other similar
events occurred during the past year. These are briefly described below.
1. On October 23, 1984 an unisolatable reactor coolant leak occurred at
Catawba Nuclear Station, Unit 1 (LER 84-18). The unit was in hot
standby with reactor coolant system (RCS) pressure at 1500 psig and
temperature at 440F. The leak occurred when the stainless steel
conduit containing an incore thermocouple separated from the mechanical
compression tube fitting. An approximate 5 gpm leak rate occurred and a
total of 12,000 gallons of coolant from the RCS leaked to the
containment floor and equipment sump.
Evaluation of the failure indicated that the conduit had not been fully
inserted into the fitting and the fitting had been tightened only 13/20
turns. The required number of turns is 11/4 turns. Another thermocouple
also was found to be loose. The cause of the failure was evaluated as
a construction/installation deficiency.
2. Two events occurred at the Rancho Seco Nuclear Plant. The first
occurred on April 20, 1984, when a 3/8 stainless steel sensing line
blew out of a compression fitting under system pressure (2200 psig)
following routine recalibration of a pressurizer level transmitter. The
second event occurred on July 31, 1984. A leak was noticed on a steam
generator level transmitter sensing line fitting. An attempt to tighten
the fitting worsened the leak. Before attempting to further tighten the
fitting the technician tapped the sensing line with a wrench, whereupon
the stainless steel line blew out of the fitting.
Both of the fittings involved were installed during or after a 1983
refueling outage. A decision was made to inspect 1444 compression
fittings installed during that period. The inspection revealed that
approximately 3% of the tube fittings were improperly made up as a
result of poor workmanship. A few instances of improperly oriented or
missing ferrules were found as gross errors, but the majority of the
deficiencies found concerned the improper location of the ferrule with
respect to the end of the tube.
These problems were attributable to poor workmanship in the cutting of
the tubing and also to potential spring back of the tubing after firm
seating in the fitting during initial assembly.
.
IN 85-55, Supplement 1
May 14, 1985
Page 3 of 4
3. On October 25, 1983, a dewater and air drying operation was being
conducted at 39 thimble locations on the seal table at D. C. Cook Unit
1. The reactor was at about 50% power throughout the 2-day effort. At
the conclusion of the maintenance effort, all guide tube connections
were checked and found satisfactory except for one. This fitting had
apparently not been properly assembled because the middle high-pressure
seal came loose causing the thimble to rise approximately 5 inches
above the seal table before it stopped. Clamps were reconnected to
prevent any further rising of the thimble out of the core.
Discussion:
Compression fittings are used throughout nuclear plants in primary,
secondary, and auxiliary systems. In some applications, failure of a fitting
may be nothing more than a nuisance. In other applications serious events
could follow the failure of one of these fittings; however, past failures of
fittings cannot be traced to any one single source. The examples cited
indicate that the failures are varied and can include the following:
improper maintenance, improper installation, improperly designed tools, and
improper materials.
In the Sequoyah event, modifications made to the cleaning tool were not
controlled adequately by existing formal programs. There were no records
that any of the modifications to the tool had been technically evaluated or
tested to determine their effect on the thimble tube seal. Lack of such
controls appears to have been a significant precursor to the event that
occurred.
In the Trojan, Rancho Seco, D. C. Cook, and Catawba events, the immediate
cause was improper installation of the fittings coupled with corrective
maintenance on the fittings while the RCS was hot and pressurized.
Compression fittings exhibit a mode of failure involving pullout of the
tubing from the fitting when subjected to an axial load. Tensile tests have
demonstrated this mode of failure can occur when the ferrule is improperly
located on the tube during initial assembly. When this occurs, it can cause
a substantial reduction in the-safety factor of the fitting. Thus,
maintenance on the fitting under these conditions has led to a substantial
number of fitting failures.
Some events involving the failure of compression fittings have become known
because of the circumstances that followed the fitting failure. However,
because of the varied applications of the compression fitting, many failures
of fittings, or problems associated with the fittings, probably go
unreported. Because of the number of severe events that have occurred during
the past year, it is appropriate that positive steps be taken to reduce the
number of similar events from occurring.
In this regard, some utilities have revised procedures on the assembly and
maintenance of these fittings to address the problems mentioned above. They
also have upgraded training efforts on the assembly and maintenance of the
fittings and have enacted stricter controls on when maintenance can be
conducted (e.g., restricting maintenance on fittings used in hot,
pressurized systems). Additionally, Westinghouse is developing fitting
inspection guidelines and detailed acceptance criteria.
.
IN 85-55, Supplement 1
May 14, 1985
Page 4 of 4
In the original IE information notice, reference was made to the failure of
"SWAGELOK" fittings. It was found that at Sequoyah and Trojan the
compression fittings used were hybrid fittings assembled using parts from
other vendors, including Crawford Fitting Co. Brand names of other
compression fittings include SNO-Trik, Gyrolok, Megalok, Ringlok, Unilok,
Wadelok, etc. Apparently, many of the parts are used interchangeably. In the
case of Sequoyah, "Gyrolok" and "Swagelok" parts were used to construct the
fittings. Therefore, use of the name "SWAGELOK" fitting in the above
applications was inaccurate. A "SWAGELOK" fitting has a nut, front and back
ferrule, and body, all manufactured by Crawford. In fact, Crawford cautions
against interchanging parts of tube fittings made by other manufacturers
with "SWAGELOK" tube fitting parts.
No specific action or written response is required by this information
notice. If you have any questions regarding this matter, please contact the
Regional Administrator of the appropriate NRC regional office or the
technical contact listed below.
Edward L. Jordan Director
Division of Emergency Preparedness
and Engineering Response
Office of Inspection and Enforcement
Technical Contact: D. Powell, IE
(301) 492-7155
Attachment: List of Recently Issued IE Information Notices