NIOSH Mining Software


AQE - Air Quantity Estimator

Version: 1.3  (03-15-2006)

See also: NIOSH mining products
Type: Analysis Software
Version: 1.3  (03-15-2006)
Operating System: Windows® (all versions)
Audience: Underground Miners
Installation Notes: Once the installation program is downloaded and unzipped, run setup.exe to install the program and necessary support files on the hard disk. The default installation folder is C:\Program Files\NIOSH\AQE.
download button
ZIP
14.82 MB

Air Quantity Estimator screen shotThe Air Quantity Estimator (AQE) provides a starting point for estimating the air quantity needed to dilute diesel particulate matter (DPM) in an underground large-opening mine, taking into account various input assumptions. The AQE estimates the total air quantity needed to dilute DPM emissions that enter the main airstream of the mine to statutory levels. It helps operators pinpoint vehicles that are high DPM contributors. It also allows the user to make “what if” scenarios by varying the input parameters (e.g., the addition of filters, use of cleaner engines, etc.) to achieve the most efficient and practical ventilation system. Engine data must be known or estimated with some accuracy and assumptions must be made in order to limit the variability of the program output. The program does not ensure adequate face ventilation and personal exposure compliance.

To receive a CD version of the Air Quantity Estimator contact:

Roy H. Grau
Pittsburgh Research Laboratory
412-386-6562
RGrau@cdc.gov

Related Documents:

Page last updated: September 17, 2008
Page last reviewed: January 30, 2008
Content Source: National Institute for Occupational Safety and Health (NIOSH) Mining Division