Millstone Nuclear Power Station, Connecticut |
|||||||||||||||||||||||||||||||||||||||
Update: August 22, 2008
Next Update: August 2009 Millstone Nuclear Power Station Net Generation and Capacity, 2007
Description: Millstone complex was built by a consortium of utilities. The power plant is located at a former quarry in Waterford, Connecticut. The site covers about 500 acres. Three reactors were located here, but Millstone 1 was shut down in November 1995 and never re-started. The other two units were shut down between 1996 and 1998 due to safety problems. Millstone 1 was being permanently closed in July 1998. In August 2000, units 2 and 3 were sold to their current owner, Virginia-based Dominion Resources, Inc. Millstone, Unit 2
Nuclear Steam System Supplier (NSSS Vendor) = Combustion Engineering Millstone, Unit 3 Nuclear Steam System Supplier (NSSS Vendor) = Westinghouse Electric Pressurized-Water Reactor (PWR) In a typical commercial pressurized light-water reactor (1) the reactor core generates heat, (2) pressurized-water in the primary coolant loop carries the heat to the steam generator, (3) inside the steam generator heat from the primary coolant loop vaporizes the water in a secondary loop producing steam, (4) the steam line directs the steam to the main turbine causing it to turn the turbine generator, which produces electricity. The unused steam is exhausted to the condenser where it is condensed into water. The resulting water is pumped out of the condenser with a series of pumps, reheated, and pumped back to the steam generator. The reactors core contains fuel assemblies which are cooled by water, which is force-circulated by electrically powered pumps. Emergency cooling water is supplied by other pumps, which can be powered by onsite diesel generators. Other safety systems, such as the containment cooling system, also need power.
Containment: According to the U.S. Nuclear Regulatory Commission, both units include pressurized light water reactors (PWR). The containment for unit 3 is dry, subatmospheric.1 The constainment type for unit 2 is dry, ambient pressure.2 _________________________________________ 1Dry, Subatmospheric: a reactor containment design which is held a negative (sub-atmospheric) pressure (i.e., a vacuum) during normal operations. When a pipe breaks or a steam release occurs in this design, much of the initial internal pressure rise is countered by the negative pressure that is already present. As a result, the final pressure reached is lower than that which would have occurred if the containment had started out at zero psig (atmospheric pressure). NOTE: If the expected containment pressure buildup from steam in an accident is say, +10 psig; and the containment walls will burst at 8 psig; - you can eliminate the possibly of a containment failure by simply starting out at negative 5 psig instead of 0 psig. So when the accident occurs, the pressure will rise from -5 psig to just +5 psig and still be safe. |
see also:
annual
nuclear statistics back to 1953
projected electricity capacity to 2030
international
electricity statistics