05/03/2001 - Fall protection requirements for workers engaged in "roof blocking." |
![]() |
Standard Number: | 1926.501(b)(1); 1926.501(b)(13); 1926.501(b); 1926.501; 1926.501(b)(10) |
May 3, 2001 Joseph J. Novak 1399 Vischers Ferry Road Clifton Park, New York 12065-6390 Re: 1926.501(b)(10); 1926.501(b)(13); STD 3-0.1A; personal fall arrest; safety monitors; warning lines. Dear Mr. Novak, This is in response to your November 15, 2000 to the Occupational Safety and Health Administration (OSHA) in which you ask us to discuss fall protection requirements for workers engaged in "roof blocking." You ask if the requirements are different for carpenters as opposed to roofing contractors. We apologize for the delay in providing this response. Background We understand "roof blocking" to be framing that is added around a hole (used for ventilation, heating, air conditioning, or other equipment) in a low sloped roof whichprovides support for equipment and aids in sealing the roof. The type of roof blocking we are referring to is not part of the support structure of the roof. This type of blocking may be installed in one of two ways. In one method, blocking installation is done as an integral part of the installation of the weatherproofing material for the roof. The worker installs roofing material up to the roof hole, installs the blocking, and then continues installing the roofing material (including up and around the blocking). When done this way, since it is an integral part of installing the weatherproofing material, it is considered "roofing work." Another method is to install the blocking separately -- before installation of the weatherproofing material begins. When done this way, it is not a part of roofing work. Section 1926.501(b) defines "roofing work" as: "the hoisting, storage, application, and removal of roofing materials and equipment, including related insulation, sheet metal and vapor barrier work, but not including the construction of the roof deck."In general, OSHA's fall protection standard, §1926.501, requires that each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. However, under §1926.501(b)(10), Roofing work on Low-sloped roofs, employers engaged in roofing work are permitted to use a combination of the additional methods listed below:
A carpentry contractor may be engaged in "roofing work"; if so, the methods in §1926.501(b)(10) would be available. In answer to your question, the classification of this work as "roofing work" under §1926.501(b)(10) does not depend on whether it is done by a roofing contractor or a carpentry contractor. Whether roof blocking is considered to be roofing work depends instead on the installation method used, as described above. The activity and not the trade of the worker determines which requirements apply. Please let us know if you need any further clarification on this subject and feel free to contact us again by writing to: Directorate of Construction-Office of Construction Standards and Compliance Assistance, Room 3468, 200 Constitution Avenue, N.W., Washington, D.C. 20210. Sincerely Russell B. Swanson Director, Directorate of Construction |
![]() |
![]() |
www.osha.gov | www.dol.gov |
Contact Us | Freedom of Information Act | Customer Survey Privacy and Security Statement | Disclaimers |
||
Occupational Safety & Health Administration 200 Constitution Avenue, NW Washington, DC 20210 |