Search Options | ||||
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us |
General Information or Other | Event Number: | 37116 | |
REP ORG: | INGERSOLL-DRESSER PUMP COMPANY | NOTIFICATION DATE: | 06/26/2000 |
LICENSEE: | INGERSOLL-DRESSER PUMP COMPANY | NOTIFICATION TIME: | 16:30[EDT] |
CITY: | HUNTINGTON PARK REGION: 4 | EVENT DATE: | 06/26/2000 |
COUNTY: | STATE: CA | EVENT TIME: | [PDT] |
LICENSE#: | AGREEMENT: Y | LAST UPDATE DATE: | 06/26/2000 |
DOCKET: | PERSON | ORGANIZATION | |
GAIL GOOD | R4 | ||
VERN HODGE | NRR | ||
NRC NOTIFIED BY: | BILL SHAFER | ||
HQ OPS OFFICER: | STEVE SANDIN | ||
EMERGENCY CLASS: | N/A | ||
10 CFR SECTION: | |||
CCCC 21.21 | UNSPECIFIED PARAGRAPH |
EVENT TEXT
PART 21 REPORT INVOLVING A DESIGN DEFECT IN A SPLIT RING RETAINER (DRAWING B65573)
"This report is written to satisfy the requirements of paragraph 21.21.4. The numbering of the information given here correlates with the numbering in 21.21.4: (i) Bill Shaffer
Director of Operations
Ingersoll-Dresser Pump
5715 Bickett Street
Huntington Park, CA 90255
(ii) Split Ring Retainer
Drawing B65573 Rev.
(iii) Ingersoll-Dresser Pump
5715 Bickett Street
Huntington Park, CA 90255
(iv) The Split Ring Retainer (Drawing B65573 Rev. 0) specifies a drilled and counter bored bolt hole diameter too large to allow the bolting to secure this retainer in its intended position. Based on an evaluation of this condition, it has been determined that this design defect could allow the subject Split Ring Retainer and other adjacent parts including the Split Ring Retainer bolting, split ring and pressure reducing sleeve to move out of position. This could result in a seal failure or a catastrophic pump failure.
(v) IDP Huntington Park was informed of this defect on 6-22-00.
(vi) Three defective split ring retainers were manufactured. The location of all three are known to IDP-HP. Three were shipped to STP Nuclear Operating Co. One of the defective split ring retainers was installed and put into service at STP.
(vii) On June 23rd Dennis Stark of STP was notified of the defective split ring retainer and that it could result in a catastrophic failure. Replacement split ring retainers with corrected design will be shipped by June 30, 2000.
(viii) IDP-HP advised Dennis Stark of STP that the pump with the installed defective split ring retainer should be taken out of service."