  Table 8

 
Table 8. Intralaboratory results for evaluation of XRD silica method
Item
Filter loading
69.4 µg
98.4 µg
204 µg
Degrees of freedom
12
11
12
RSD for sampling and analytical methods (%)*,
8.8
6.3
8.1
Source: NIOSH, BOM [1983].
*RSD = relative standard deviation. RSD for sampling and analytical methods represents the RSD in mass estimates, accounting for intersampler and analytical variability.
Implications for XRD: Pooled filter levels and pump error (assumed to be <5%) indicate that the overall imprecision is as follows: Total RSD for sampling and analytical methods is 9.3%. Therefore, the upper 95% confidence limit on the accuracy (35 degrees of freedom) is 21%.
corner image line image
corner image line image
  Table 9

 
Table 9. Intralaboratory results for evaluation of IR silica method
Item
Filter loading
67.2 µg
99.7 µg
161µg
Degrees of freedom
10
12
11
RSD for sampling and analytical methods (%)*,
5.8
7.8
7.4
Source: NIOSH, BOM [1983].
*RSD = relative standard deviation. RSD for sampling and analytical methods represents the RSD in mass estimates, accounting for intersampler and analytical variability.
Implications for IR: Pooled filter levels and pump error (assumed to be <5%) indicate that the overall imprecision is as follows: Total RSD for sampling and analytical methods is 7.1%. Therefore, the upper 95% confidence limit on the accuracy (33 degrees of freedom) is 17%.
corner image line image
corner image line image
  Table 10

 
Table 10. XRD method evaluation: concentration ranges bracketing applicable exposure limits for which the NIOSH accuracy criterion is met* ( µg/m3)
Cyclone and sampling rate
Filter loading
Applicable exposure limit
69.4 µg
98.4 µg
204 µg
Nylon cyclone, 1.7 L/min
85
121
251
100
GK2.69 cyclone, 4.2 L/min
34
49
102
50
*Eight-hour sampled masses are combined with results of NIOSH, BOM [1983].
corner image line image
corner image line image
  Table 11

 
Table 11. IR method: concentration ranges bracketing applicable exposure limits for which the NIOSH accuracy criterion is met* ( µg/m3)
Cyclone and sampling rate
Filter loading
Applicable exposure limit
6.72 µg
99.7µg
161 µg
Nylon cyclone, 1.7 L/min
83
123
198
100
GK2.69 cyclone, 4.2 L/min
34
50
80
50
*Eight-hour sampled masses are combined with results of NIOSH, BOM [1983].