The U.S. Nuclear Regulatory Commission (NRC) receives reports from its licensees under Part 21 of Title 10 of the Code of Federal Regulations. This regulation specifies the conditions under which information must be submitted when a licensed facility, activity, or basic component fails to comply with the Atomic Energy Act of 1954, as amended, or other NRC regulations.

Recently Updated Reports

The following links on this page are to documents in our Agencywide Documents Access and Management System (ADAMS). ADAMS documents are provided in either Adobe Portable Document Format (PDF) or Tagged Image File Format (TIFF). To obtain free viewers for displaying these formats, see our Plugins, Viewers, and Other Tools. If you have problems with viewing or printing documents from ADAMS, please contact the Public Document Room staff.

Log No.
Notifier
Description
Report Date
Event No. / Accession No.
2008-19-00

Namco Controls

Namco Supplied Clear Thread Sealant Instead of White Thread Sealant 10/03/2008 ML082800337
2008-18-00

Applied Analysis

Software Error Giving Incorrect Flow Rates for Highly Throttled Flow Control Valves 09/23/2008 ML082760159
2008-17-00

Spectrum Technologies

Siemens Model 353 Process Controller Transformer Failure 09/19/2008 ML082671066
2008-16-00

Fisher

Fisher Valve Actuator Nitrile/Nylon Diaphragms (Part No. 1R6375X0072) Inadequately Cured and Inappropriately Overstressed 08/28/2008 ML082460801
2007-20-02

General Electric

Nonconservatism in GE STRM Thermal-Mechanical Methodology--Extension to GNF2 Fuel Design

(Enclosure 1 is proprietary and not publicly available.)
08/28/2008 ML082420310
2008-15-00

GE Hitachi

Failure of Safety-Related Switch in AK-2A-50 Circuit Breaker 08/25/2008 ML082390106
2008-14-00

Flowserve

Butterfly Valve Failed in Test 07/15/2008 ML081990210
2008-13-00

ABB

Transient Suppression of 59 D/H Overvoltage Relay 07/09/2008 ML081960457
2008-10-01

TMI

Joslyn Clark Controls NC Contacts 07/09/2008 ML081960118
2008-12-00 Fisher 3-Inch Valves Provided with Incorrect Seal Rings 06/26/2008 ML081830523
2008-11-00 Oconee Replacment Breaker Charging Motors Failed Minimum Voltage Test 06/23/2008 ML081760330
2008-10-00 TMI Joslyn Clark Relay Contact Configuration 06/13/2008 ML081700094
2008-09-00 Hatch Hydrogen Embrittlement of Wire Clamps in CR120A Relays 04/29/2008 ML081330284